Laserfiche WebLink
i <br />• <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton.. California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Costco Wholesale #1031 <br />Facility Address: <br />2440 Daniels ST, Manteca <br />Date: <br />August 18, 2016 <br />SUMMARY OF VIOLATIONS <br />(CLASS 1, CLASS II, or MINOR- Notice to Comply) <br />Item # Remarks <br />316 HSC 25290.1(c3), 25290.2(c3) Secondary containment not constructed to prevent water intrusion (after Jul 2003). <br />Water was found in the 87 east STP sump. Secondary containment shall be constructed to prevent any water <br />intrusion into the system by precipitation, infiltration, or surface runoff. The service technician removed liquid from <br />the sump and returned the sensor to its proper location. Immediately contact a properly licensed, trained, and <br />certified contractor to address the water intrusion into the 87 east STP sump under permit and inspection of the EHD. <br />This was corrected on site. <br />This is a minor violation. <br />318 <br />CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi. <br />The 87A and 87B line leak detectors failed to detect a leak when tested. All line leak detectors shall be capable of <br />detecting a 3 -gallon per hour leak at 10 psi. The service technician changed the siphon jets on the 87 turbines, <br />retested the leak detectors, and they passed. <br />This was corrected on site. <br />This is a minor violation. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by October 9, 2016. <br />'The monitoring system certification was completed on 8/18/16, but there was not enough time to complete the <br />paperwork portion of the inspection. The paperwork inspection was conducted on 9/9/16. The inspection report <br />was provided on 9/9/16 upon completion of the full inspection. <br />Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br />documents into the California Environmental Reporting System (CERS): LIST Monitoring Site Plan, UST <br />Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br />applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br />Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br />Documents reviewed: CERS submittals, Designated operator (DO) monthly inspection reports, DO training log, <br />alarm history, work orders, alarm/maintenance logs <br />Documents provided: Return to Compliance Certification form <br />Page 5 of 6 <br />