Laserfiche WebLink
Z <br /> PANEL A MAIN/GENERAL BREAKER RATED: 10,000 A.I.C. * LISTED FOR SERIES w qZQ <br /> VOLTAGE: 120/208 VOLT-30, 4-WIRE MAIN BRKR: M.L.O. COMBINATION WITH CURRENT TO UTILITY SERVICE BY POWER (12) CAT 5 4PR #24 <br /> BUSS: 225A SPACES: 42 LIMITING MAIN FUSE. COMPANY (SEE E-1 ) FAULT BY GAS G.0 SEE NOTE #2 <br /> CIRCUIT PHASE EXISTING UTILITY VAULT OR CURRENT 22,000 A.I.C. (2) #12 THWN Z <br /> # DESCRIPTION LOAD BREAKER A B C NOTES LCL POLE BY POWER COMPANY (1) #12 GND. TO CONTROLLER PPP--- <br /> LEFT SIDE (ODD CIRCUITS) CONTRACTOR TO INSTALL (1)-3" 18"X18"X6" NEMA 3R ENCLOSURE 139 BY GAS G.C. ENCLOSURE z (5 0- <br /> W/ DUPLEX RECEPTACLE FOR J Q } <br /> 1 MODEM VEEDER ROOT, D-BOX CAMERAS VIA UPS 2640 30-1 2640 U UNDERGROUND PVC CONDUIT (SCHEDULE F F- <br /> 3 CANOPY LIGHTS 1 940 20-1 940 SW-1 Y 80) AS REQUIRED BY POWER COMPANY. CAMERA POWER SUPPLY BY GAS _ q-17 w <br /> 7 CANOPSPAICETS 2 900 FILOLER 0 940 SW-1 Y A-17 d <br /> G.C. SEE NOTES #2 & #4 (TYP.) W Z J <br /> (EXACT LENGTH AS PER PLAN.) p, U <br /> 9 CANOPY LIGHTS 3 774 20-1 774 SW-1 Y CONTRACTOR TO INSTALL UTILITY PAD A-15 -15 Z � � W < <br /> 11 CANOPY LIGHTS 4 774 20-1 774 SW-1 Y SEE NOTES #1 & #4 28 (FUTURE - INSTALL o LL <br /> MOUNT TRANSFORMER VAULT WITH A-15 J _t5 , a Lu <br /> J <br /> 13 SPACE 0 FILLER 0 (TYP.) ON EXPANSION ,SIDE wfn <br /> 15 CANOPY LIGHTS 5 986 20-1 986 SW-1 Y CONCRETE PAD MINIMUM OF 10' FROM ti <br /> OF CANOPY) C co w U Z <br /> 17 SIGNS FASCIA 1 SECURITY LTS 1270 20-1 1270 SW-2 Y CONTROLLER ENCLOSURE AND/OR AS (1) CAT 5 4PR #24 K w co W <br /> 19 SPACE 0 FILLER 0 Y DIRECTED BY POWER COMPANY. (1) #16-2 PER CAMERA o > w W o Z Q O <br /> 21 SIGNS FASCIA #2/SECURITY LTS 1505 20-1 1505 SW-2 Y <br /> 23 SPACE 0 FILLER 0 Y (1) - #4 COPPER GROUND WIRE. BY GAS G.C. _ :D U a U (J) <br /> 25 SPACE 0 FILLER 0 Y 2„ C, (4) #3/0 THWN C.U. SEE NOTE #3 C) Z <br /> 27 CANOPY LIGHTS 6 FUTURE 0 FILLER 0 SW-1 Y + (1) #4 C.U. E.G. 3/4" x 10 COPPER CLAD o E5 w W O ('f <br /> 29 CANOPY LIGHTS 7 FUTURE 0 FILLER 0 SW-1 STEEL GROUND ROD VIDEO CAMERA BELOW. a m ° = W Q <br /> 31 SPACE 0 FILLER 0 - 2" C, (4) #3/0 THWN C.U. + (1) #4 E.G. VIDEO CAMERA TO FACE 141 J 140 VERIFY LOCATION WITH N N N V C-4 <br /> v <br /> 33 CONTROLLER ENCLOSURE AC HEAT 2500 30-2 2500 TOWARD TANK AREA PROJECT MANAGER 8 co <br /> 35 CONTROLLER ENCLOSURE AC HEAT 2500 30-2 2500 NEMA 3R, 200A, 200A FUSE (TYPE JJN) A-15 A-15 (TYP. 8) Y Y Y Y Y <br /> 37 SPACE 0 FILLER 0 NEMA 3R, 200A, METER MAIN SERVICE DISCONNECT SWITCH MOUNTED ON vs W Q O <br /> 39 SPACE 0 FILLER 0 COMBINATION SAFETY SOCKET WALL OF CONTROLLER ENCLOSURE . A-3 A-3 = s = s = <br /> 41 SPACE 0 FILLER 0 MOUNT ON EXTERIOR WALL OF SQ D CAT NO. D324-NR-8 ,/{ J —� Q U 3 U <br /> RIGHT SIDE EVEN CIRCUITS CONTROLLER ENCLOSURE A-17 0 0 0 0 <br /> 2 SURGE DIVERSION - BUILDING 10 30-3 10 EUSERC COMPLIANCE 65,000 CONCRETE ENCASED GROUNDING FOCUS LIGHT FIXTURE <br /> 4 SURGE DIVERSION - BUILDING 10 30-3 10 AIC CIRCLE AW CAT N0. U227 ELECTRODE. SEE DETAIL F' (TYP 16) 136 N ` ^ o \ o a <br /> 6 SURGE DIVERSION - BUILDING 10 30-3 10 SHEET E-4. o o <br /> 8 SPACE 0 FILLER 0 MTB <br /> 10 SPACE 0 FILLER 0 WITH TEST BYPASS -- ® _ F ----_ _ _____, A-g (- <br /> A-11 NOTE: <br /> 12 CONTROLLER ENCLOSURE LIGHTS 720 20-1 720 Y I I CENTER ROW OF CANOPY LIGHTS <br /> 14 FE PETRO IST 1 960 20-3 960 1 2 C, (4) #3/0 THWN 1 <br /> 16 FE PETRO IST 1 960 20-3 960 1 <5' I SHALL BE WIRED TO THE SAME <br /> 18 FE PETRO IST #1 960 20-3 960 1 1 CIRCUITS AS THE FASCIA LIGHTING <br /> 20 FE PETRO IS 2 960 20-3 1 960 II FOR NIGHT TIME SECURITY <br /> 22 FE PETRO IST 2 960 20-3 960 I (4) #4 GND. CONTROLLER CONSIDERATIONS WHEN STATION IS <br /> I <br /> 24 FE PETRO IST 2 960 20-3 960 I ENCLOSURE NOT OPEN. <br /> 26 FE PETRO IST 3 960 20-3 960 I 1 SIGN LIGHTER, CENTER 135 <br /> I OVER SIGN. (TYP. 4 27 A-3, A-5, A-9, <br /> 28 FE PETRO IST 3 960 20-3 960 I POWERBOX <br /> SURGE A-11, A-15 <br /> MODEL: CSTC0618021 <br /> 30 FE PETRO IST 3 960 20-3 960 I I CANOPY LIGHT FIXTURE <br /> 32 SPACE RESERVED FOR IST 4 0 I GND. I A-9 A-11 <br /> 34 SPACE RESERVED FOR IST4 0 1 1 136 J <br /> 36 SPACE RESERVED FOR IST 4 0 I 1 (HIGH IMPACT) NOTE: <br /> 38 SUB FEED TO PANEL B 9900 100-2 9900 I NEUT. ISOLATED I (TYP. 15) A-3 A-21 -3 A-17 HOME RUN LOCATIONS SHOWN ARE <br /> 40 SUB FEED TO PANEL B 2364_ 100-2 2364 1 NO. GND. I TYPICAL. CONTRACTOR RESPONSIBLE <br /> 42 - - -- - - -- - I A-21 <br /> I <br /> I 1. J FOR SITE SPECIFIC LOCATIONS. <br /> TOTAL VA 15430 11959 9094 1 -A- IIN <br /> LCL 0 4205 3704 j 120/208 20 B PO j NOTE: A-11 Q <br /> 1 Ll7GS 120208 I CAMERA LAYOUT SHOWN IS A_g W Op <br /> PLUS 25% 0 1051 926 1 ONLY SUB FEED I TYPICAL. CONTRACTOR w 01 <br /> I I RESPONSIBLE FOR ACTUAL <br /> TOTAL VA 15430 13010 10020 I o 1 CAMERA LAYOUT TO MEET SITE ® W � <br /> AMP PERP 128.3 108.2 83.3 I I SPECIFIC OWNER COVERAGE / " <br /> I 1 REQUIREMENTS AS NOTED. FEE 4 CAMERA <br /> FEED CONDUIT <br /> PANEL LOAD 106.6 FROM ® J <br /> I CONNECTED LOAD = 36.5 KVA 1 CONTROLLER <br /> PANEL B DISPENSERS/ELECTRONICS L_______________ 1 A-9 A-11 <br /> ENCLOSURE � d <br /> VOLTAGE: 120/208 VOLT-10, 3-WIRE MAIN BRKR FEED FROM -A- BREAKER RATED: 10,000 A.I.C. __________ _____ ® p9 <br /> BUSS: 100A SPACES: 20 ACTUAL A.IC. BELOW 4,000 (3) #3 THWN C.U. <br /> CIRCUI PHASE (1) #8 GND C.U. <br /> DESCRIPTION LOAD BREAKER NOTES LCL Single <br /> + A- -5 3/4" 120 VAC <br /> # A B /� Sin le Line �ia ram A 21 0 0 SUPPLY CONDUIT <br /> LEFT SIDE (ODD CIRCUITS) E_3 1111 <br /> NOT TO SCALE <br /> J <br /> 1 DISPENSER 1 960 20-1 960 12"X10"X4" DUPLEX RECEPTACLE <br /> 3 <br /> 5 DISPENSER #2 960 20-1 960 1FOCUS MICRO <br /> 7 A-9 A-11 CAMERA 18"X18"X6" NEMA <br /> 9DISPENSER 3 960 20-1 1 960 A-1 7, A-21 POWER 3R ENCLOSURE <br /> 11 SUPPLY <br /> 13 DISPENSER #4 960 20-1 960 NIL <br /> 15 lL <br /> 17 DISPENSER #5 960 20-1 960 L <br /> 19 1o <br /> RIGHT SIDE EVEN CIRCUITS TYPICAL 3/4" POWER AND <br /> 2 DIS ENSER #6 960 TO-1 960 VIDEO CAMERA TO CAMERA FEED CONDUIT TO CV S <br /> 4 � m FACE CONTROLLER 141 A-9 J A-11 CAMERA LOCATIONS. C6 <br /> 6 DISPENSER 7 FUTURE 960 20-1 960 0 <br /> 8 � � ENCLOSURE A-5 A-21 A-5 NUMBER AS REQUIRED. �Q <br /> 10 DISPENSER 8 FUTURE 960 20-1 960 z a H V 0 <br /> 12 ° TYPICAL NEMA 3R ENCLOSURE DETAIL <br /> 14 T EQUIP ---1-5-0-0— 30-2 1500 OPW A-21 <br /> $ <br /> FUTURESPARUIPMENT 1�00 20-1 720 1500 �a eR NA�Fy <br /> _ p� SCALE: NTS oFEssra <br /> 20 QUAD ECEPT. - GENERALUSE 864 20-1 864 POWER CORD SET SUPPLED WITH UPS 1 Canopy Lig Itln Plan ma=y HAL a. Rue ?„ <br /> TOTAL VA 9900 2364 A <br /> LCL 0 0 �SCALE: 1 /8"= i �-O" <br /> PLUS 25% 0 0 30/0,P�_A v I <br /> v <br /> TOTAL VA 9900 2364 FCl <br /> o m Op CpA_\F���'� <br /> AMP PER P 82.5 15.5 <br /> 0 o CONTROLLER <br /> PANEL LOAD 49.0 n 117 ENCLOSURE s <br /> NOTES: " s <br /> U. TERMINALS ARE PROVIDED TO ALLOW THIS CIRCUIT TO BE WIRED THROUGH AN EXTERNAL UNINTERRUPTIBLE POWER LEFT SIDE OF 3.0 KVA UPS <br /> SUPPLY. POWERBOX CABINET CORD CONNECTED x s x S o <br /> jVEEDERR "ISW-1 . CIRCUIT IS WIRED THROUGH STAGE #1 OF THE MANUAL SWITCHES.SW-2. CIRCUIT IS WIRED THROUGH STAGE #2 OF THE MANUAL SWITCHES. I blUPS ConnectionLCL. LONG CONTINUOUS LOAD. E-3 NOT TO SCALEOPW. OPW USER INTERFACE REQUIRES LOCKABLE BREAKER PER CARB E.O. PANEL ENCLOSURETRIP SNOW MELTING EQUIPMENT (WHEN USED) REQUIRES THE USE OF 30-ma GROUND FAULT PROTECTION 11 A-12PER NEC CODE AND EQUIPMENT MANUFACTURER INSTALLATION SPECIFICATIONS. 36" CLEARANCE z RUSE SQUARE D Q0120EPD BREAKERS OR EQUAL. THESE BREAKERES ARE TO BE PROVIDED BY THE CAMERA INSTALLATION NOTES: 200A MAIN DISCONNN � <br /> INSTALLING CONTRACTOR. PER N.E.C. C w X aF <br /> 1 .) GAS G.C. TO TERMINATE CAMERA CONDUIT RUNS AT CAMERA LOCATIONS WITH NEMA 3R 2"C, 4#3/0 THWN E z4X4 J-BOX. LEAVE 3 FEET OF WIRING IN J-BOX FOR FINAL CONNECTIONS MADE BY FOCUS & 1#4 GND. B p a" cNvcNo4 O N.1ciMICBO. PHONE RINGERz `° m Z WN2.) CAMERA VIDEO FEEDS MUST BE CONTINUOUS FROM CAMERA LOCATIONS TO PHONE A 128 SUPPLIED BY ^ a Lo ,�, EsBOARD TERMINATION BOX AT CONTROLLER ENCLOSURE. NEMA 3R ENCLOSURE IS USED FOR GAS G.C. 3 N N zzA PASS THROUGH POINT ONLY. NO SPLICING OF CAMERA FEEDS ARE PERMITTED. CAT 5 C11 t� <br /> CE-2 LO �CABLES MUST BE RATED FOR WET LOCATIONS. 200A METER, 3-PH, 2 A/C UNIT °D "'A33+35 <br /> It <br /> 3.) CAMERA POWER FEEDS FROM POWER SUPPLY AND THE CAT 5 VIDEO FEED CABLES FROM 3 KVA <br /> THE CAMERAS MAY BE RUN IN SAME CONDUIT TO THE NEMA 3R ENCLOSURE. <br /> 1EMERGENCY SHUT-OFF <br /> 10 <br /> 4.) LEAVE 3 FEET OF WIRING IN THE NEMA 3R ENCLOSURE FOR TRIMMING OUT THE POWER 911 PHONE 123 � z <br /> FEEDS. <br /> EQUIPMENT TO FACE116 ACKNOWLEDGMENT SWITCH <br /> TOWARD TANKS (TYP.) <br /> 115 OVERFILL ALARM bb'a 4 aaNgJy r <br /> NOTE: <br /> NOTE: AC UNIT IS PROVIDED FOR MAINTAINING A <br /> ENCLOSURE LAYOUT SHOWN IS TYPICAL. CONDITIONED AREA FOR THE ELECTRICAL <br /> SEE SHEET T-1 & E-1 FOR ACTUAL Typical Controller EQUIPMENT NOT FOR COMFORT CONDITIONING; <br /> CONTROLLER ENCLOSURE THEREFORE COMPLIANCE WITH THE ENERGY B 4 ch <br /> CONFIGURATION. Z Enclosure Power Plan CODE IS NOT REQUIRED z' N <br /> a <br /> 4. <br />