z
<br /> A LEFT WALL ELEVATION REAR WALL ELEVATION rcRIGHT WALL ELEVATION D FRONT WALL ELEVATION o
<br /> E-2 SCALE: 1"=1 '-0" E-2 SCALE: 1 "=1 '-0" �_2 SCALE: 1 "=1 '-0" E^2 SCALE: 1 "=1 '-0"
<br /> 11'-6, 5'-9" 11 '-6" 5'-9„
<br /> Ilk — - Q f
<br /> 46" 1'-2 5y4L." 6" 33" 1 14" 4" 15" 3' 25" 36" 8" 16" 14" o
<br /> oJWa
<br /> [V q c Q Q W Z
<br /> w SEE NOTE #4 W W W
<br /> LEFT WALL WINDOW o Fc 0
<br /> ORIENTATION THIS SIDE GILBARCO ENCLOSURE o Q
<br /> D-BOX o ^ POWERBOX [ ALIGN HV/I.S. PARTITION IN / Q W
<br /> 1 1 T
<br /> um I /I WIREWAY WITH HV I.S. DIVISION DROP CEILING z V (n
<br /> z o DISTRIBUTION / / Z W J
<br /> U-15 Iw o CENTER I ON VEEDER ROOT MODULE / w W V Z
<br /> (PDC) moo/ z CL l j - Q
<br /> Z m m w
<br /> SUMP IDE SIDE ALLIED I SEE NOTE #5 I VEEDER R �/ _ w Q m Q co
<br /> _ ANDI z
<br /> 5y4" 6" 5y4" A-19 + B-19 + BOX (CONDUIT LOCATION UNDER U-1i I �o/ AIR g a � m a Z
<br /> N POWERBOX CENTER I N
<br /> 11 CONTRACTOR DISCRETION. I / CONDITIONER m 1- Q O
<br /> MAG MAG MAG 111 w I 12 n v w N n Y i C N U
<br /> VFC VFC VFC GSM
<br /> U-15 I ARRANGE TO MINIMIZE I o >
<br /> GSM A-1 CROSSING OF CONDUCTORS) N z I / /w35iR
<br /> 33
<br /> A- ,
<br /> 726 A 126 126 so I 129 o
<br /> UNL ` UNL PREM N w N I _ Q 3Q U
<br /> N V N N N
<br /> A 6 C 124 I _ � CONDUIT ENCLOSURE UNDER I 110 124 U-14 © 121 LIGHT SWITCH
<br /> CABINET BY G.C. i © B--20 I PRE-WIRED
<br /> woo-
<br /> 111 A-1 k w- z - 6"x6"x18" 6"x6"x42" A-1 0 0 ^o ^o
<br /> MEDIA FILTER 125 UPS QUAD 124 6'x6'x36 '
<br /> BOX RECEPT. WIREWAY W/ GSM © © © © o z IF REQUIRED 11 i5 HV © m 31 0 I \ A-12 ` Z
<br /> io ® © WIREWAY WIREWAY © ©
<br /> DIVIDERS U-15U-15 I z w 11 U-14 I.S.
<br /> 6"x6"x36" WIREWAY
<br /> 61 62 63 64 13 15 17 19 3 I I W I 72 34 68 66 34 33 22 39 41 43 45 76 75 74 58 \ in "'' "' "' z'
<br /> FIBER/PHONE U-150 ©
<br /> ® © 57 65 fi 66 8 67 10 fib 11 72 14 16 18 22 3 to 24 5 67 65 35 32 40 42 44 46 38 37 36 55 59 7
<br /> TERMINATION A-1 25
<br /> � 70
<br /> RECEPTACLE A/C
<br /> OBOO I 69 64 62 57 25 27 28 30 32 55 I I I \
<br /> 4 ( I W W 49 63 61 24 26 O 31 33
<br /> $0
<br /> 2 70 56 1 1 t 1 - SEALOFF Z (
<br /> i 4 5 N (TYP.) I I W 120 d O
<br /> I1i7a o I I FINISHED
<br /> FLOOR I \
<br /> — - - - - — — - - III 11 ; 1 ; I ; 1 ; 1 ;
<br /> — — — — — — — ; ; ; ; ; ; ; ; I 1 1
<br /> 11111
<br /> 1 , 111 , 1 ,
<br /> o i �
<br /> t 19 ' ' ' ' ' ' ' ' 1 CAMERA WIRING LAYOUT
<br /> O , , , , , 111
<br /> 4' I 1 I 1 1 1 1 1 ; 1 ; 1 ' 1 ; 1 ; W
<br /> z ; i i i ; i CAMERA #1 — POINTS TO DISPENSERS t AND 2 (ILBARCO DISPENSER WIRE COLOR REFERENCE -1 N
<br /> CAMERA #2 - POINTS TO DISPENSERS 3 AND 4 CO OD
<br /> CAMERA #3 - POINTS TO DISPENSERS 5 AND 6 1. BLACK #12: NOT TO A-2 (CD MODULE) & VARISTOR w c®
<br /> I 1
<br /> 2. GREEN #12: TO A-10 (GROUND) W 8D
<br /> CAMERA #4 - POINTS TO DISPENSERS 7 AND 8 ( J
<br /> 3. WHITE #12: NEUTRAL TO A-13 (CD MODULE) & VARISTOR
<br /> 4. RED #12: TO STP11W R7
<br /> CAMERA #6 - POINTS TO DISPENSERS 11 AND 12 W
<br /> CAMERA #7 - POINTS TO DISPENSERS 13 AND 14 5. BLUE #12: : PARE TR2
<br /> 6. YELLOW 12: SPARE NOTE:
<br /> CAMERA #8 - POINTS TO DISPENSERS 75 AND 16 # ® Q�
<br /> t T ; ; , ; i — ; i ; i ; ; ; ; i ; i ; i ; CAMERA #9 - POINTS TO CONTROLLER ENCLOSURE 7. YELLOW #14: SPARE ALL WIRE TO BE THWN, ('
<br /> CAMERA #10 - POINTS TO TANK FARM 8. NOT USED OIL AND GAS RESISTANT Q
<br /> I ' ' i i i i i NO EXCEPTIONS
<br /> U -' --- --- - ------- --- ------------- - ------- '----------- ----- 1 , 1 , 9. PINK N #1 SPARE ® � (n`
<br /> r-�--- --�-------------------- J I ; I , I , #
<br /> _ ___ _ - _-- ----- 10. BROWN 14: SPARE U
<br /> --- ------ ------
<br /> rJ 11. #74: TO B-9 (GRIND TWO WIRE OUT (-)) BLACK TWISTED PAIR
<br /> __________ ______ \
<br /> -- -------------- --- ------------ ------ -- ------------------------j I 1 , I , I , 1 >NON INSULATED
<br /> --- ----------------------J ---_-_--_-_-_----- -----
<br /> T r- -----_ J 1 ' ' L __ _ 1 12. #14: TO B-19 (CRIND TWO WIRE IN (+)) WHITE NON SHIELDED
<br /> 1 1 1 I - --- -
<br /> IILI111 ---------------------- 1 1 I 1 _ -- 1 I I
<br /> r- -
<br /> ------------ L___ l I I 1 i I 14. #14: TO A-19 (PUMP TWO WIRE IN (+)) RED NON SHIELDED L
<br /> I `'--------------- ---- 11111
<br /> SHEET NOTES
<br /> , , i i 1 I I i I
<br /> a_________________ ! ° ' + ' ' - ' ' ' ' I I 1. ROUTE CONDUIT TO EQUIPMENT AS INDICATED ON SHEET E-1.
<br /> �� ------- i-- i-- I �'--- '-- T1 i i ; ; i i ; i ALL CONDUIT PENETRATION FITTINGS SHALL USE STAINLESS W
<br /> ----- -------------- -------------
<br /> 1 -------------- -- -------------- T-- , I 1 , 1 I i I I I I I I I a
<br /> L-- ------------ jr �_ ---1� 1 STEEL CONDUIT ENTRY NIPPLES AND SWEEPS. W
<br /> ( L_________________Tt___,1 2. ROUTE CONDUIT AND CONDUCTORS TO EXTERIOR OF LJU i�
<br /> I I ; 1 , 1 I 1 ; 1 '1 CONTROLLER ENCLOSURE WALL AS INDICATED ON SHEET E-1.
<br /> PVC CONDUITS - TO 1 ; , , 1 1 1 , � ' 1 , ' , 1 , , I .. 1 1 1 1 W
<br /> BE ROUTED BELOW I ' i I ' I ' i i I ' i I ' RL ENDL3. GENERAL CONTRACTOR TO TERMINATE CAMERA CONDUITS/WIRE
<br /> I I , I , , 1 I 1 I 1 I 1 I N
<br /> FREEZE LEVEL BELOW CANOPY DECK INTO DOUBLE GANG ELECTRICAL BOX, �� S
<br /> 42 85 98 1 85 98 42 85 98 42 42 85 98 24 ' 24 '
<br /> 1 I I I , I , I , , , ( , , , , I , 1 I 1 1 1 1 24 �� LEAVING APPROXIMATELY 3 LENGTH OF WIRE/CABLE FOR FlNAL Ii;1
<br /> 1 1 EQUIPMENT HOOKUP BY OWNER'S CAMERA CONTRACTOR. FIBER f-
<br /> LLL
<br /> I I I 38 37 _ 36 _ LENGTH TO BE 20' EXTRA 0 EACH END. U 0
<br /> CONDUITS RUN UNDER , O2 �1 9O , ' ' 14 13 I , "
<br /> 12 , 14 , 16 , , 1 ' 19 , •e 1 C PVC GOA D
<br /> OFWORK
<br /> SCOPE i �__-_- t 39 - J I I ; -- 10 - 4t __J I 1 ; st _ , ; L----- t (1) ( 1� 4. FUNCTIONS OF THE CONTINUOUS MONITORING:
<br /> {5} {} 43 - I 45 -- 2 BELDEN 887fi01 FESSIak
<br /> ( ) # -MONITORING OF ALL ANNULAR SPACES. Qty q�
<br /> ' ' 19 t9 , (1) #12 GND. -MONITORING OF ALL PRODUCT PIPING SUMPS. yea F4
<br /> 56 49 ; 69 27 1 , 26 28 ' ' '
<br /> z9 ( ' 30 ; o ' nm I I -PROVIDE .1 GPH PRESSURE LINE LEAK DETECTION (PLLD) OF
<br /> ENTRANCE- I 139 ' 1 ' I I 1 ' 1 0 ' I �o ' I �? � ' 19
<br /> t 4 3 3 ' i 1 , , SEE NOTE ; 1 Y ; 1 y N I Y "� PRODUCT LINES.
<br /> CAMERA POWER 25# PULL 140 25# PULL ; 40 # #3 (TYP.) ,� 1 ,� I w I
<br /> 2 35 35 O ' ' 25 PULL ' 1 140 ' , z , < z y , a , -PROVIDE CONTINUOUS TANK LEVEL MONITORING.
<br /> SUPPLY'MOUNTED IN ' a z -DISPENSER SUMP MONITORING. �LA1
<br /> E.D.P. ROOM 110 I CORD (TYP,) CORD (TYp,) ' CORD I (TYp,) 10 ; - - a ee(1) 1" C (PVC COA D 6/30 L `
<br /> 18x18x6 NEMA 3R POIN1T (4) BELDEN #88760 -IN SYSTEM DIAGNOSTICS. �IYi� ��P
<br /> i ENCLOSURE I ; ' I ; ' ; ' 40 , ' 6 " ' ' a ' ' 11 - ' THE CONTINUOUS MONITORING DEVICE SHALL PROVIDE POSITIVE r R
<br /> TANKS 10 FNi, p
<br /> (E.D.P. ROOM LOCATION 1 (1) #t2 GND s8 5s SHUTDOWN OF TURBINES AND DISPENSERS AUTOMATICALLY IN OF CAL R 2 ;
<br /> SHOWN SCHEMATICALLY, POINT AT ; ; 1 ,
<br /> CONTRACTOR TO DETERMINE CONTROLLER ° ; 1 ° ; 1 ° ; 1 ° ; _ _J t - L _ --/ THE EVENT OF A LIQUID RELEASE AND MANUALLY THROUGH
<br /> ACTUAL LOCATION. i (NP•) 7435 THE ESO SWITCH LOCATED S THE CONTROLLER ENCLOSURE _ x
<br /> t3 15 n is 19 29 35 _
<br /> L ----------- 51 - __ L--- stc ___ --- 51 ___J L----- 51G - ___J 19 29 35 19 29 35 AND REMOTE ESO SWITCH AS INDICATED ON SITE PLAN.
<br /> sis
<br /> WAREHOUSE O O{} J O O42 J �Q Od O O4s TURBINE END VENT STACKS 5. ALL WIRES ENTERING CONTROL PANELS, MAIN PANELS, s o
<br /> 4 3 8 7 1 11 16 15 AND SUB PANELS SHALL BE MARKED WITH PHASE TAPE a
<br /> ENTRANCE/EXIT AREA OVERFILL CODING AS FOLLOWS:
<br /> ALARM 0 12'-0" A.F.F AND 42 85 98 42 85 98 42 85 98 42 85 98 WIRING LEGEND "A" PHASE = BLACK
<br /> ACKNOWLEDGE SWITCH ® 4 -0' "B" PHASE = RED m xl
<br /> A.F.F. (ALWAYS) & REMOTE POWER CONDUIT "C" PHASE = BLUE
<br /> EMERGENCY SHUT-OFF SWITCH x s °
<br /> (IF REQUIRED) — POWER & DATA CONDUIT CONTRACTOR TO LABEL TURBINES AND CONTROLLERS AS TO WHICH
<br /> MOUNTED AT EACH DISPENSER SIDE OF THE STATION THEY SERVE. GREEN CONTROLLER .LIGHTS
<br /> 10 (nP ) - - CAMERA/COMM. CONDUIT ARE TO GO OUT WHEN TURBINES ARE OFF OR LOSE POWER, o
<br /> NOTE: -------------- INTRINSICALLY SAFE CONDUIT 6. SEE DETAIL "J" ON DWG. T-5 AND DETAILS "A", "D" & "G" ON
<br /> G.C. SHALL INSTALL A DEDICATED, UNSWITCHED 103 MOUNTED AT DISPENSER
<br /> FOURPLEX OUTLET IN EDP ROOM AND A CLOSEST TO TANK FIELD ONLY CONDUIT RUN SCHEMATIC FROM CONTROLLER ENCLOSURE ® INDICATES ITEM ON MATERIALS LIST SEE DWG. T-7 DWG. T-4 FOR TANK MONITORING DEVICES. a
<br /> DEDICATED, UNSWITCHED DUPLEX OUTLET BY A 7. WALL MOUNTED EQUIPMENT LOCATIONS ARE FIXED .AS SHOWN F z M
<br /> BURGLAR PANEL IN EDP ROOM UNDER WAREHOUSE NTS INDICATES DISPENSER NUMBERING AND POSITION REGARDLESS OF CONTROLLER ORIENTATION, G.C. SHALL NOT =o z
<br /> SCOPE OF WORK. o
<br /> MOUNT EQUIPMENT OTHER THAT WHAT IS SHOWN. 0 �
<br /> CONDUIT SCHEDULE C'4 LN
<br /> z W
<br /> CONDUIT CONDUIT 'CONDUIT CONDUIT CONDUIT CONDUIT CONDUIT CONDUIT CONDUIT CONDUIT CONDUIT CONDUIT CONDUIT CONDUIT CONDUIT ¢ 0 N r z 'aNS
<br /> PURPOSE FILL FILL PURPOSE FILL PURPOSE FILL PURPOSE FILL o
<br /> # SIZE # SIZE # SIZE # SIZE # SIZE Z rn I I w E
<br /> < Qi 2" PHONE SERVICE TO EDP ROOM (2) 25 PAIR PHONE WIRE, (1) #12 GND. •• ALL YdFTE RALS BY OAS GG U4LE880TFERWI9E NOT® 1" 4 In an Z
<br /> cq
<br /> Q 2" SECURITY TO WAREHOUSE EDP ROOM (2) 5 PAI (2) E WIRE.
<br /> e• ® 1" DISPENSER POWER 4112 TM,: 4(14, (2)114 TM'ISTED PAIR & 1#12 GND. ® 3/4' LOOP TO CAMERA PANEL (2) #12 THWN, (2) #12 GND. es ® 3/4" DISPENSER SENSOR & ISD COMPONENTS (3) BELDEN CABLE #88760 (1) #12 GND. • © 3/4" LOOP FOR POWER - UNLEADED A (3) #10 THWN, (i) #10 GND. ^ 3 N N a O d
<br /> < © 1" DISPENSER POWER 4112THMN: 4114, (2) 114TMMPAIR & 1112 GND. (D 1' LOOP TO RIGHT WALL RECEPTACLE (2) #12 THWN, (1) #12 GND. �� ® (NOT USED) • ® 3/4" LOOP FOR POWER - UNLEADED B (3) #10 THWN, (1) #1C GND. CONDUIT LEGEND
<br /> < Q3 1° EDP TO BURGLAR PANEL 0 ENTRY AREA (2) 18-2, (2) 18-6 • ® 1" DISPENSER POWER 4112 THWN; 4114, (2) 114 TM75TED PAIR & 1112 GND. ® 1" LOOP TO RIGHT WALL E.S,O. AND V.R. (5) #12 THWN, (2) #12 GND. �� ® (NOT USED) • ® 3/4" LOOP FOR POWER - PREMIUM C (3) #10 THWN, (1) #10 GND. a PVC COATED WOD METAL CONDUIT eff E RUM � Y v.`Li v t=i1
<br /> CONTROLLER ENCLOSURE TO ee ee PVC COATED ROD METAL CONDUIT LAST 2'INTO N
<br /> < ® 1° FlBER OPTIC - TO EDP ROOM TWELVE STRAND (5MM K JACKET) * ® 1" DISPENSER POWER 41121KMY; 4#14, (2)114 TNM PAR G70. ® 3/4° ESO/VEEDER ROOT ALARM 0 ENCLOSURE (5) #12 THWN, (1) #12 GND. ® 3/4" CAMERA POWER SUPPLY (2) #12 THWN (1) #12 GND. • ® 3/4" FUTURE LOOP FOR POWER - PREMIUM D 25# PULL CORD BRINE SUMPS `r1 4 .0 w
<br /> Q5 3/4" LOOP TO 911 PHONE (2 PR) PHONE CABLE, (1) #12 GND. •*S ® (NOT USED) ® 1" VEEDER ROOT ALARM ® WAREHOUSE ENTRY/EKR (3) #10 THWN, (1) #10 GND. ® 2" DATA LOOP TO FIBER/PHONE BOARD AS REQUIRED CURRENT COSTCO I.S. SETUP • ® 3/4" DISPENSER HOOKS - UNLEADED A (2) #12 THWN, (1) #12 GND. * F ONLY N 4 ISLAND OR 3 ISLAND V,`" N7'�y Q
<br /> ++• Q i" UNLEADED TANK #1 TURBINE POWER (3) #12 THWN, (1) #12 GND. •e ® (NOT USED) •e ® 1" PREMIUM TANK #3 MONITORING DEVICES (7) BELDEN CABLE #88760 (1) #12 GND. eO ® (B) 1' DISPENSER ETHERNET COMMUNICATION CABLING #25 PULL CORD • ® 3/4" DISPENSER HOOKS - UNLEADED B (2) #12 THWN, (1) #12 GND. EXPANDABLE T04181.MD KX)Ngd1FtATtON3.
<br /> •+ < +* RECUPiED ONLY N 5 O AND OR 4 ISLAND Q G q
<br /> ) (NOT, USED) ® i" LOOP TO VEEDER ROOT 25# PULL CORD •e ® 1° UNLEADED TANK #2 MONITORING DEVICES (7) BELDEN CABLE #88760 (1) #12 GND. ® (NOT USED) • ® 3/4" DISPENSER HOOKS - PREMIUM C (2) #12 THWN, (1) #12 GND. EXPANDABLE TO5OAND CONFIQURAIIOMS. ., ,z� u
<br /> ++• 1° UNLEADED TANK #2 TURBINE POWER (3) #12 THWN, (1) #12 GND. ® (2) 2" DISPENSER WIRING - LOOPS TO POWER CENTER '2'11'21 +8 1P2G N� SRECE RTLE) CONDORS e• ® '1° UNLEADED TANK #1 MONITORING DEVICES (7) BELDEN CABLE #88760 (1) #12 GND. ® (NOT USED) • ® 3/4" FUTURE DISPENSER HOOKS - PREMIUM D 25# PULL CORD < NEW WARBiOIlsE, WIRE PLII_L BY OWNER LS.C#ROUF', I i o
<br /> EXISTING WAREHOUSE ALL PULS BY GC.
<br /> Q9 (NOT USED) ® 2" LOOP TO DISCONNECT (4) 3/0, (4) #4 GND. ee ® 3/4" DISPENSER SENSOR & ISD COMPONENTS (3) BELDEN CABLE #88760 (1) #12 GND. ® (NOT USED) ® 1" FUTURE EQUIPMENT 25# PULL CORD ADDITIONAL WFM_ (S►l Jv
<br /> GNOSTICS
<br /> ++e ® 7" PREMIUM TANK #3 TURBINE POWER (3) #12 THWN, (1) #12 GND.* ® 3/4" FUTURE AIR/WATER REEL 25# PULL CORD e; ® 3/4" DISPENSER SENSOR & ISD COMPONENTS (4) BELDEN CABLE #88760 (1) #12 GND. ® 3/4" VAPOR SAVER LOOP FOR POWER (2) #12 THWN & (2) #12 GRD. ® 3/4" FUTURE PHONE UNE TO VEEDER ROOT PANEL 25# PULL CORD + 09D)PRESSURE SENSOR REOUIREDATDISPENSER
<br /> 12 CAT 5 4PR 24 AWG BELDEN 7928A CLOSEST TO TANKS.CONTRACTOR TO FIELD VERPY
<br /> ++e © 1" PREMIUM TANK #3 TURBINE POWER (SPARE) 25# PULL CORD ® 3/4" FASCIA/SECURITY LIGHTS - A-17, A-27 (3) #10 THWN, (1) #10 GND. ee ® 3/4" DISPENSER SENSOR & ISD COMPONENTS (3) BELDEN CABLE #88760 (1) #12 GND. ® 1-1/4" CAMERA FEEDS TO CANOPY OIL RESISTA ® (NOT USED) LOCATION 'a
<br /> •e ® 1" DISPENSER POWER 4112 THWN; 4114, (2) 114 TM161PD PAR & 1112 GND. ® 1" CANOPY LIGHTS - A-3, A-5, A-9, A-11, A-15 (8) #10 THWN, (1) #10 GND. •• ® 3/4" DISPENSER SENSOR & ISD COMPONENTS (3) BELDEN CABLE #88760 (1) #12 GND. ® 3/4" POWER LOOP TO PHONE PANEL (2) #12 THWN, (2) #12 GND. ® (NOT USED) ++USE W THWN AND W GND FOR RUNS OVER 4710'
<br /> •• ® 1° DISPENSER POWER 4#12 TM; 4114,,(2) 114 TMt51PD PAR & 1112 OND. ® 1" CANOPY LIGHTS - FUTURE 25# PULL CORD w ® 3/4" DISPENSER SENSOR & ISD COMPONENTS (3) BELDEN CABLE #88760 (1) #12 GND. ® 1° FUTURE (POWER/COMM) 25# PULL CORD ® (NOT USED) (TYPO
<br /> •• ® 1" DISPENSER POWER 41121HMN; 4114; (2) 114 TWISLFD PAIR& 1112 CND. ® 3/4° ESO TO DISPENSERS (2) #12 THWN, (1) #12 GND. se ® 3/4" DISPENSER SENSOR & ISD COMPONENTS (3) BELDEN CABLE #88760 (1) #12 GND. ® 1" FUTURE DIAGNOSTIC 25# PULL CORD e• ® t" PREMIUM TANK #3 VAC. MONITORING DEVICES (3) BELDEN CABLE #98760 (i) #12 GND. d N N
<br /> •• ® t" DISPENSER POWER 4112I MN; 4114;(2) 114 TMISIED PAR & 1112 GND. ® 3/4" ESO TO DISPENSERS (2) #12 THWN" (1) #12 GND. •i ® 3/4° DISPENSER SENSOR & ISD COMPONENTS (3) BELDEN CABLE #88760 (7) Al- GND. ® (NOT USED) ee ® 1" UNLEADED TANK #2 VAC. MONITORING DEVICES (3) BELDEN CABLE #88760 (1) #12 GND. a r " W 6,
<br /> s• ® 1" UNLEADED TANK #1 VAC. MONITORING DEVICES (3) BELDEN CABLE #88760 (1) #12 GND. ti
<br />
|