Laserfiche WebLink
MONI�RING SYSTEM CERTIF TION RECE v ED <br /> For se By All Jurisdictions Within the State of coli ornia 2 d Z��9 <br /> Authority Cited. Chapter 6.7,Health and Safety Code, Chapter 16,Division 3, Title 13, California Code 0%V <br /> e ons <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or repoE.W�6L�'Yit�W Ytir� <br /> monitoring system control Panel by the technician who performs the work A copy of this forth must be provided to the tar Wb1}u 6" r. <br /> The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> FacilityName: CHARTER WAY CHEVRON Bldg.No.: <br /> Site Address: 508 W. Charter Way City: Stockton CA Zip: 95206 <br /> Facility Contact Person: Surinder Singh Saini Contact Phone No.: (209) 465-3440 <br /> Make/Model of Monitoring System: Veeder Root TLS-350 Date of Testing/Servicing: 10/22/2009 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the approvriate boxes to indicatespecific a ui ment inspected/serviced: <br /> Tank ID: T1: 87 Tank ID: T2: 91 <br /> ❑In-Tank Gauging Probe. Model: ❑In-Tank Gauging Probe. Model: <br /> ®Annular Space or Vault Sensor. Model: 794380-420 ®Annular Space or Vault Sensor. Model: 794380.420 <br /> ®Piping Sump/Trench Smsor(s). Model: 794380.208 ®Piping Sump/Trench Sensor(s). Model: 794380-208 <br /> ❑Fill Sump Sensor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> ❑Mechanical Line Leak Detector, Model: ❑Mechanical Line Leak Detector. Model: <br /> ®Electronic Line Leak Detector. Model: 8484 ®Electronic Line Leak Detector, Model: 330376.002 <br /> ❑Tank Overfill/High-Level Sensor. Model: ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: T3: Diesel TankrD: <br /> ❑In-Tank Gauging Probe. Model: ❑In-Tank Gauging Probe. Model: <br /> ®Annular Space or Vault Sensor. Model: 794380-420 ❑Annular Space or Vault Sensor. Model: <br /> ®Piping Sump/Trench Sensor(s). Model: 794380-208 El Piping Sump/Trench Sensor(s). Model: <br /> [I Fill Sump Sensor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> ❑Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> ®Electronic Line Leak Detector. Model: 8484 ❑Electronic Line Leak Detector. Model: <br /> ❑Tank Overfill/High-Level Sensor. Model: ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 112 Dispenser ID: 314 <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ®Shear Valve(s). ®Shear ser Containment <br /> ®Dispenser Containment Floats)and Chein(s). ®Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5/6 Dispenser ID: 718 <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ®Shear Valve(s). ®Shear Valve(s), <br /> ®Dispenser Containment Float(s)and Chain(s). ®Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ❑Shear Valve(s). ❑Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Cham(s). <br /> 'If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certifll,atiOn -I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br /> correct and a Plot Plan showing the layout of monitoring a uipment" For any equipment capable of generating such reports,I have also <br /> attached a copy of the report;(check all that apply): a System set-up ❑ Alarm history report <br /> Technician Name(print): Robert Barnhart Signature: I)fldk_ky�ha <br /> Certification No.: B35969 License.No.: 983706 <br /> Testing Company Name: Reliable Petroleum Service Inc Phone No.:(209) 845-8586 <br /> Testing Company Address: 521 Branding Iron Street Oakdale CA 95361 Date of Testing/Servicing: 10/22/2009 <br /> Page 1 of 4 <br /> UN-036—1/4 <br /> www.unidocs.org <br /> Rev.01/17/08 <br />