My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2007-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DR MARTIN LUTHER KING JR
>
749
>
2300 - Underground Storage Tank Program
>
PR0231060
>
COMPLIANCE INFO 2007-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/26/2024 2:39:10 PM
Creation date
11/4/2018 3:20:31 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2012
RECORD_ID
PR0231060
PE
2361
FACILITY_ID
FA0003870
FACILITY_NAME
SRH FOOD & GAS
STREET_NUMBER
749
Direction
E
STREET_NAME
DR MARTIN LUTHER KING JR
STREET_TYPE
BLVD
City
STOCKTON
Zip
95206
APN
14734309
CURRENT_STATUS
01
SITE_LOCATION
749 E DR MARTIN LUTHER KING JR BLVD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\D\DR MARTIN LUTHER KING JR\749\PR0231060\COMPLIANCE INFO 2007-2012.PDF
QuestysFileName
COMPLIANCE INFO 2007-2012
QuestysRecordDate
3/29/2018 3:42:52 PM
QuestysRecordID
3839705
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
389
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
7 <br /> SWR <br /> CB,January 2002 Page_of_-.,. <br /> 7. UNDER-DISPENSER CONTAINMENT UDC TESTING <br /> Test Method Developed By: D UDC Manufacturer D Industry Standard Professional Engineer <br /> D Other(Specify) —- <br /> Test Method Used: D Pressure D Vacuum Hydrostatic <br /> D Other(Spec) _ <br /> Test Equipment Used: Equipment Resolution: <br /> UDC UDC# UDC# UDC# <br /> UDC Manufacturer: <br /> UDC Material: <br /> UDC Depth: <br /> Height from UDC Bottom to Top <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to <br /> testing: - <br /> Portion of UDC Tested <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both Yes No DNA Yes No DNA Yes No DNA Yes No DNA <br /> product and water)? <br /> Turbine shutdown response time <br /> Is system programmed for fail- Yes D No D NA Yes D No D NA Yes D No D NA Yes D No DNA <br /> safe shutdown? <br /> Was fail-safe verified to be Yes No DNA Yes No DNA Yes No DNA Yes No DNA <br /> operational? -- -- <br /> Wait time between applying <br /> water and starting test — <br /> Test Start Time: <br /> Initial Reading(Rj): — <br /> Test End Time: - <br /> Final Reading RF): - <br /> Test Duration: — <br /> Change in Reading(RF-Ri): --- <br /> Pass/Fail Threshold or Criteria: <br /> Test Result: Pass D Fail Pass D Fail Pass CI Fail Pass D Fail <br /> Was sensor removed for testing? Yes D No D NA Yes D No D NA Yes D No DNA Yes D No D NA <br /> Was sensor properly replaced and Yes D No DNA Yes D No D NA Yes D No ❑NA Yes D No D NA <br /> verified functional after testis ? -__ <br /> Comments- (include information on repairs made prior to testing and recommended follow-up forpiled tests) <br /> Not Tested with this event! <br /> If the entire depth of the UDC is not tested,specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(*) is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.