My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2007 - 2010
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DUCK CREEK
>
3633
>
2300 - Underground Storage Tank Program
>
PR0232461
>
COMPLIANCE INFO 2007 - 2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:11 PM
Creation date
11/4/2018 3:46:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007 - 2010
RECORD_ID
PR0232461
PE
2361
FACILITY_ID
FA0003758
FACILITY_NAME
RYDER TRUCK RENTAL #1071
STREET_NUMBER
3633
STREET_NAME
DUCK CREEK
STREET_TYPE
DR
City
STOCKTON
Zip
95215
APN
17331001
CURRENT_STATUS
01
SITE_LOCATION
3633 DUCK CREEK DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\D\DUCK CREEK\3633\PR0232461\COMPLIANCE INFO 2007 - 2010.PDF
QuestysFileName
COMPLIANCE INFO 2007 - 2010
QuestysRecordDate
4/25/2018 11:45:33 PM
QuestysRecordID
3869854
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
277
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
From: 01/27 2009 17:03 #347 P.0061011 <br />6. PIPING SUMP TESTING <br />'lest Method Developed By: <br />_1 Sump Manufacturer X Industry Standard <br />- Professional <br />Engineer <br />J Other (Specify) <br />Test Method Used: <br />0 Pressure <br />:_ 'Vacuum <br />X Hydrostatic <br />€.l Other (Speeifi) <br />Test Equipment Used: Ronan/Caldwell Hydrostatic Sump Tester <br />Equipment Resolution: <br />0.0000'' <br />Waste Oil <br />New Oil <br />Maio Diesel <br />Reserve Diesel <br />Sump Diameter: <br />47'• <br />42" <br />42„ <br />42„ <br />Sump Depth: <br />42" <br />80" <br />79" <br />I 79" <br />Sunip Material. <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Height from Tank Top to Tap of <br />Highest Piping Penetration: <br />-12" <br />„12" <br />-14" <br />-12" <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />1'" <br />-14" <br />-17" <br />_15" <br />of sump prior to testing: <br />Dirty <br />Clean <br />Clean <br />Clean <br />Portion of Sump Tested' <br />17' <br />-20" <br />_1811 <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />Yes E No NA <br />1u° Yes `0 No x NA <br />x Yes i� No :.', NA <br />x Yes 'O No ! _1 NA <br />product and water)'?' <br />Turbine shutdown response time <br />NiAA <br />N/A <br />--6 sec <br />-6 sec <br />Is system programmed for fail-safe <br />shutdown?' <br />Yes ::1 No x NA <br />D'� Yes i_ No x NA <br />x Yes 7_' No NA <br />x Yes C No C i NA <br />Was fail-safe verified to be <br />o erational?' <br />Yes 1.1 No x NA <br />DI Yes No x NA <br />x Yes D No ;-1 NA <br />x Yes t� No (l NA <br />Wait tinge between applying <br />pressure/vacuum/water and starting <br />5 min <br />5 min <br />5 min <br />5 min <br />test: <br />Test Start Time: <br />8:30 am <br />8:30 am <br />9:15 am <br />9:15 am <br />Initial Reading (R,); <br />Test End Time: <br />9:00 am <br />9:00 am <br />9:45 am <br />9:45 am <br />Final Reading (Rr): <br />Test Duration: <br />30 min <br />30 min <br />3Q min <br />30 min <br />Change in Reading (Rr-Rt): <br />Q <br />0 <br />Q <br />Pass/Fail Threshold or Criteria: <br />PASS = No Loss or Loss of 0.0020" or less in 30 minutes <br />Test Result: <br />x Pass ` 0 Pail <br />x Pass 0 Fall <br />x Vass 0 Fail <br />x Pass 0 Fail <br />Was sensor removed for testing? <br />x Yes Ll No 10 NA <br />x Yes _- No 11 NA <br />x Yes No L NA <br />x Yes No �] NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />x Yes ':! No :INA <br />x Yes No .-1 NA <br />x Yes F: No D NA <br />x Yes No ':INA <br />Comments - (include ir?ffi"n ttion on repairs made prior ro reminrg, ai2c� recontnserrrled,f�iliaiv-u .for fittlad resr�) <br />Note: Caldwell Sump Tester used for hydrostatic test. <br />' If the entire depth of the sump is not tested, specify ]tow much was tested. if the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />