My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DUCK CREEK
>
3633
>
2300 - Underground Storage Tank Program
>
PR0232461
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2023 3:03:36 PM
Creation date
11/4/2018 3:52:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0232461
PE
2361
FACILITY_ID
FA0003758
FACILITY_NAME
RYDER TRUCK RENTAL #1071
STREET_NUMBER
3633
STREET_NAME
DUCK CREEK
STREET_TYPE
DR
City
STOCKTON
Zip
95215
APN
17331001
CURRENT_STATUS
01
SITE_LOCATION
3633 DUCK CREEK DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\D\DUCK CREEK\3633\PR0232461\BILLING 2015.PDF
QuestysFileName
BILLING 2015
QuestysRecordDate
4/26/2018 7:57:02 PM
QuestysRecordID
3871781
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
122
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
o oo• o0 0�� <br /> �-o <br /> UNIFIED PROGRAM CONSOLIDATED FORM <br /> UNDERGROUND STORAGE TAMC <br /> MONITORING PLAN- Pae I or 2) <br /> TYPE OF ACTION ❑ I.NEW PLAN PIµ 2.CHANGE OF INFORMATION <br /> PLAN TYPE Eal L MONITORING IS IDENTICAL FOR ALL USTS AT THIS FACILITY, 690,z <br /> (Check one item only) ❑ 2.THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEMS) <br /> L FACILITY INFORMATION <br /> FACILITY ID R(Agency Use Only) _ 5 <br /> BUSNESS NAME(Same as FACILITY NAME) I Lq,f T -t,L GI'1 eX(�(t E i L r� 3 <br /> BUSINESS SITE ADDRESS '7 (�kf_If C, 101' CITY '�° <br /> + fC'/"7 <br /> II:EQ7MENT TESTING AND PREVENTIVE MAINTENANCE <br /> Testing,preventive maintenance,and calibration of monitoring equipment(e.g.,sensors,probes,line leak detectors,etc.)must be performed at the frequency <br /> specified by the equipment manufacturers'instructions,or annually,whichever is more frequent,and that such work must be performed by qualified personnel. <br /> 23 CCR 2632 2634,26X 2641 <br /> MONITORING EQUIPMENT IS SERVICED I.ANNUALLY ❑ 99.OTHER(Specify): 690-3e <br /> 490.36 <br /> III.MONITORING LOCATIONS <br /> 1.NEW SITE PLOT PLA /MAP SUBMITTED WITH THIS PLAN. 2.SITE PLOT PLANIMAP PREVIOUSLY SUBMITTED. (23 CCR§2632, <br /> 2634)49 <br /> N.TANKMONTtORING 1$PERFORMED USING TAE FOLLOWING D(S): <br /> I.CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR(INTERSTITIAL)SPACES)OR SECONDARY CONTAINMENT 74K5 <br /> VAULTS)W ITH AUDIBLE AND VISUAL ALARMS.jj223 CCR§2632,2634) <br /> __ SECOND_ARY CONTAINMENT IS: ❑ a.DRY,Q]] b.LIQUID FILLED ❑ c.PRESSURIZED ❑d.UNDER VACUUM <br /> �-_-- <br /> LEAKSENSORMANUFACTURER � <v0-lo <br /> 2.AUTOMATIC TANK GAUGING(ATC)SYS-EEM USED TO MONITOR SINGLE WALL TANKISI.(2J CCR§2643) 490.11 <br /> PANEL MANUFACTURER: 690,12 MODEL k_ 490-13 <br /> IN-TANK PROBE MANUFACTURER: _ __ °90"'+__M_O_DEL : 69°-15 <br /> ------------ <br /> LEAK TEST FREQUENCY: ❑ a.CONTINUOUS ❑ b.DAILYMk_S).______ <br /> IGHTLY ❑ c.WEEKLY 090,.15 <br /> d_MONTHLY _ ❑ e OTHERS n +9o-19 <br /> PROGRAMMED TESTS: ❑ a.0.1911 <br /> g.p.h. ❑ 6.0.2 g.p.h. ❑ c.OTHER(Specify): 40. <br /> 90,-19 <br /> ❑ 3.MONTHLY STATISTICAL INVENTORY RECONCILIATION(23 CCR§2646.1): 490,xo <br /> ❑ 4.WEEKLY MANUAL TANK GAUGING(MTG)(23 CCR§2645). TESTING PERIOD: ❑ a.36 HOURS ❑ b.60 HOURS 490-21 <br /> Ll 5.TANK INTEGRITY TESTING(23 CCR§2643.1): 090.224W.23 <br /> TEST FREQUENCY: [I a ANNUALLY [Ib.BIENNIALLY [I c.OTHER(Specify): =25 <br /> ❑99.OTHER (Specify): 490-26 <br /> 490 <br /> -n <br /> V.PIPE MONITORING IS PERFORMED USING THE FOLLOWING METROD(S){Cheek all;hat apply) . ' <br /> L CONTINUOUS MONITORING OF PIPE/PIPING SUMP(S)AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE AND 49 2s <br /> ISUAL ALARMS (23 CCR§2636) ,,[ <br /> SECONDARY CONTAINMENT IS:6.DRY ❑b.LIQUID FILLED ❑c.PRESSURIZED ❑d.UNDER VACUUM 49 29 <br /> _PANEL MANUFACTURER: I/t'C!_i _Pf 490'50 I MODEL p: 490-31 <br /> LEAK SENSOR MANUFACTURER: ,�,,�...11 EE_1` 090-3_x_ MODEL k(S): _=qqs+� °90.55 <br /> �I<< _Lr_.__.__.. <br /> PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP(i.e.,TURBINE)SHUTDOWN. a.YFS ❑b.NO 490,56 <br /> FAILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. lam.YES ❑b.NO 490.35 <br /> 2.MECHANICAL LINE LEAK DETECTOR(MLLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS AND RESTRICTS OR SHUTS OFF <br /> PRODUCE FLOW WHEN A LEAK IS DETECTED_ 23 CCR 2636 _ <br /> ". �_ H-_�.___ 690,36 <br /> a9o-3i ;__�.__� <br /> MLLD MANUFACTURER(S): --I _L24 <br /> MODEL N(S): (��,�,�-�� 49o-31 <br /> ❑ 3.ELECTRONIC LINE LEAK DETECTO (ELLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS (23 CCR§2636) 490.39 <br /> ELLD MANUFA(nURERSS) °9660' : M_ODEL p(S): <br /> PROGRAMMED N LINE LEAK TEST: ❑ I.MINIMUM MONfHLY0.2 g.P.h. ❑ 2.MINIMUM ANNUAL 0,1 g.p.h. +9002 <br /> ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑a.YES ❑b.NO 49043 <br /> ELLD FAILURE/DISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑a.YES ❑b.NO 490.44 <br /> 4.PIPE INTEGRITY T S INC 49045 <br /> TEST FREQUENCY a.ANNUALLY b.EVERY 3 YEARS c.OTHER(Specify) 490.464904) <br /> 5.VISUAL PIPE MQNITORINC. Cy;j t= + Qh �./ <br /> FREQUENCY n��[a.DAILY ❑ b.WEEKLY ❑c.MIN.MdNT14LY&EACH TIME SYSTEM OPERATED- 4y 9 <br /> 'Allowed far mm,m ofwbuneJ amv morfuel i in onl NSC 25211.5 l <br /> ❑ 6.SUCTION PIPING MEETS EXEMPTION CRITERIA(23 CCR§2636(x)(3)). ago-so <br /> 7.NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 20,CHAPTER 6.7 IS CONNECTED TO THE TANK SYSTEM <br /> 490.51 <br /> ❑ 99.OTHER(Specify) 49052 <br /> 49x.53 <br /> UPCF UST-D(12/2007)1/4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.