My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2005-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
153
>
2300 - Underground Storage Tank Program
>
PR0231389
>
COMPLIANCE INFO 2005-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:31 AM
Creation date
11/4/2018 4:32:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2011
RECORD_ID
PR0231389
PE
2361
FACILITY_ID
FA0003709
FACILITY_NAME
VALERO #3698
STREET_NUMBER
153
Direction
E
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23336607
CURRENT_STATUS
01
SITE_LOCATION
153 E ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\ELEVENTH\153\PR0231389\COMPLIANCE INFO 2005-2011.PDF
QuestysFileName
COMPLIANCE INFO 2005-2011
QuestysRecordDate
5/19/2017 6:00:47 PM
QuestysRecordID
3389699
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
372
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br /> 8. Fill Riser Containment Sump Testing <br /> Test Method Developed By: ❑Tank Manufacturer X❑Industry Standard N Professional Engineer <br /> Test Method Used: N Pressure ❑vacuum NX Hydrostatic <br /> Test Equipment Used: Incon TS STS Leak Detector Equipment Resolution:±0.002 <br /> Fill Sump# 87 Fill Sump# 87s Fill Sump# 91 Fill Sump# <br /> Sump Diameter: 48" 48" 48" <br /> Sump Depth: 27" 27" 28" <br /> Height from Tank Top to Top of 0 0 0 <br /> Highest Piping Penetration: <br /> Height from Tank Top to 19" 23„ 14" <br /> Lowest Electrical Penetration: <br /> Condition of sump prior to Ok Ok Ok <br /> testing: <br /> Portion of Sump Tested: 4" 4" 4" <br /> Sump Material: -- — Fiberglass Fiberglass Fiberglass <br /> Wait time: 15 min 15 min 15 min <br /> Test Start Time: 10:36 10:36 10:36 <br /> Initial Reading: 1.7624 1.4618 0.7184 <br /> t <br /> Test End Time, —— _ 10:51 10:51 10:51 <br /> Final Reading: 1.7616 1.4630 0.7182 <br /> Test Duration(hh:mm) 00:15 00:15 00:15 00:00 <br /> ---- -- 1— — _--- --- <br /> Change in Reading: -0.0008 0.0012 -0.0002 0.0000 <br /> Pass/Fail Threshold or Criteria: lI' ±0.002 ±0.002 ±0.002 ±0.002 <br /> Test Result: Pass O Fail <br /> * Pass O Fail * Pass 0 Fail O Pass O Fai r� <br /> Is there a sensor in the sump? Yes Yes Yes I� <br /> Does the sensor alarm when <br /> either product or water is Yes Yes Yes <br /> detected? <br /> Was sensor removed forO Yes O No O NA Yes O No O NA. *Yes ONO O NA O Yes O No O NA <br /> testing? <br /> Was sensor property replaced <br /> and verified functional after * Yes ONO O NA Q Yes O No O NA *Yes O No O NA O Yes ONO O NA I <br /> i_ testing? _ <br /> Comments: <br /> 6 of 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.