BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
153
>
2300 - Underground Storage Tank Program
>
PR0231389
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:22 AM
Creation date
11/4/2018 4:35:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231389
PE
2361
FACILITY_ID
FA0003709
FACILITY_NAME
VALERO #3698
STREET_NUMBER
153
Direction
E
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23336607
CURRENT_STATUS
01
SITE_LOCATION
153 E ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\ELEVENTH\153\PR0231389\BILLING 2012-2015.PDF
QuestysFileName
BILLING 2012-2015
QuestysRecordDate
5/19/2017 9:44:43 PM
QuestysRecordID
3390673
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
152
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> illillillillillllllllIIIIIIIIIIIIIIillillililllllllllllllIllillillinspONSE PLAN-PAGE 2 <br /> We will reporVmcord any ovehll,spill,or unaudrld REPORTINGSAINDa[RECORD 101cated in this plan. <br /> KEEPING <br /> Recordable Releases: Any unauthorized release from <br /> detected or should reasonable have Primary containment which the UST operator is able to clean up within eight(8)hours after the release was <br /> Y been detected,and which does no[escape from <br /> not cause any deterioration secondary containment,most be recorded in the facility's monitoring records. Monitoring records must include: <br /> secondary containment,does not increase the hazard of fire or explosion,and does <br /> The UST operator's name and telephone number; <br /> ➢ A list of the types,quantities,and concentrations of hazardous substances released <br /> ➢ A description of the actions taken to control and clean up the release; ; <br /> The method and location of disposal of the released hazardous substances,and whether a hazardous waste manifest was Or will be used; <br /> ➢ A description Of acfions taken to repair the UST and to prevent future releases; <br /> D A description of the method used to reactivate interstitial monitoring after replacement or repair of primary containment. <br /> Reportable Releases: Any overfill, spill,or unauthorized release which escapes from secondary containment(or prima <br /> exists),increases the hazard Of fire or explosion,or causes any deterioration of secondary containment,is a reportable release. Reportable releases are also recordable. <br /> Primary containment if no secondary containment <br /> Within 24 hours after a reportable release has been detected,or should have been detected, we will notify the local agency administering the UST program n the <br /> be removed fromtheUST to Prevent further releases or facilitate iate corrective action.s to stop the release. IIf an emergency exists,we will notify the State Office of Emergency Services. <br /> ary,or if required by the local agency,remaining stored product/waste will <br /> Within five(5)working days of a reportable release,report <br /> will submit to the local agency a full written report containing all of the following information to the extent <br /> that the information is known at the time of filing the report: <br /> ➢ The UST owners or operators name and telephone number; <br /> D A list of theoxi type,quantities and concentrations of hazardous materials released; <br /> The approximate date of the release; <br /> D The date on which the release was discovered; <br /> ➢ The date on which the release was stopped; <br /> ➢ A description of actions taken to control and/or stop the release; <br /> A description Of corrective and remedial actions,including investigations which were undertaken and will be conducted to determine the nature and extent of <br /> Mil,ground water or surface water contamination due to the release; <br /> ➢ The method(s)of cleanup implemented to date,proposed cleanup actions,and a schedule for implementing the proposed actions; <br /> ardous materials and <br /> Copiesofany hazardouscOltruniria <br /> manifests used for off-sitOf released e[transport of hazardous my <br /> associated soils,ith clean-up activity; <br /> A description of proposed methods for anrepgroundwater,iv surface water. <br /> ➢ A description of additional actions taken to Prevent future releases.acementof UST system primary/second <br /> ary containment systems; <br /> We will follow the reporting procedures described above if any of the follng conditions occur: <br /> Released h <br /> ➢ A recordable unauthorized release can not be cleaned up or is still under investigation within eight(8)hours of detection; <br /> azardous substances are discovered at the UST site or in the surrounding area; <br /> ➢ Unusual operating conditions are observed,including erratic behavior of product dispensing equipment,sudden loss of product,or the unexplained presence of <br /> water in the tank,unless system equipment is found to be defective and is immediately repaired or replaced,and no leak has occurred; <br /> ➢ Monitoring results from UST system monitoring equipment/methods indicate that a release may have occurred,unless the monitoring equipment is found to be <br /> defective and is immediately repaired,recalibrated,or replaced,and additional monitoring does not confirm the initial'results. <br /> Record Retention: Monitoring records and written reports of unauthorized releases must be maintained on-site(or off-site at a readily available location,if approved <br /> by the local agency)for at least 3 years. Hazardous waste shipping/disposal records(e.g.,manifests)must be maintained for at least 3 years from the date of shipment. <br /> VII. OWNER/OPERATOR SIGNATURE <br /> CERTIFICATION:I certify that the information provided herein is true and accurate to the best of my knowledge. <br /> OWNER/OPERATOR SIGNATURE <br /> OWNER/OPERATOR NAME(print) DATE _n /I/ R,n. <br /> Rn. <br /> Sandy Huff OWNER/OPERATOR TITLE R72 <br /> Compliance Coordinator <br /> (Agency Use Only) This plan has n reviewed and: pproved <br /> ❑Approved With Conditions El Disapproved <br /> Lac[Agency Signature: <br /> Date: —U00 <br /> UN-0226.3/3 <br /> www.unidocs.org <br /> Rev.04/02/08 <br />
The URL can be used to link to this page
Your browser does not support the video tag.