My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
153
>
2300 - Underground Storage Tank Program
>
PR0231389
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:22 AM
Creation date
11/4/2018 4:35:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231389
PE
2361
FACILITY_ID
FA0003709
FACILITY_NAME
VALERO #3698
STREET_NUMBER
153
Direction
E
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23336607
CURRENT_STATUS
01
SITE_LOCATION
153 E ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\ELEVENTH\153\PR0231389\BILLING 2012-2015.PDF
QuestysFileName
BILLING 2012-2015
QuestysRecordDate
5/19/2017 9:44:43 PM
QuestysRecordID
3390673
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
152
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNIFIED PROGRAM CONSOLIDATED FORM <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN-(Pae I of 2) <br /> awl-I <br /> TYPE OF ACTION ❑ I.NEW PLAN ® 2.CHANGE OF INFORMATION 4W).2 <br /> PLAN TYPE M ].MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. <br /> (Check one item only) ❑ 2.THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEMS). <br /> I. FACILITY INFORMATION <br /> _ I <br /> FACILITY ID#(Agency Use Only) FE - <br /> BUSINESS NAME(Sam as FACILITY NAME)Valero 03698 <br /> 105. uu. <br /> BUSINESS SITE ADDRESS 153 E. 11 Street CITY Tracy <br /> II.EQUIPMENT TESTING AND PREVENTIVE MAINTENANCE <br /> Testing,prevemive main[emrlce,and ealibmtion of monimdng equipment(e.g.,sensors,probes,line leak detectors.etc)must be performed at the frequency <br /> specified by the equiplrlent manufacturers'instructions,or annually,whichever is more frequent,and that such work must be performed by qualified personnel. <br /> �23 CCR§2632,_634,2638,2641) _- ---'"-- --awo. <br /> -_-. .__-- ._-_-________-__-_._____-___---.--.-----_-.-- <br /> MONITORING EQUIPMENT IS SERVICED ® 1.ANNUALLY ❑ 99.OTHER(Specify): 4wlah <br /> III.MONITORING LOCATIONS <br /> ®1.NEW SITE PLOT PLANIMAP SUBMITTED WITH THIS PLAN. X❑2.SITE PLOT PLAN/MAP PREVIOUSLY SUBMITTED. (23 CCR§2632, <br /> 2634)491r <br /> IV.TANK MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S): 4915 <br /> I.CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR(INTERSTITIAL)SPACES)OR SECONDARY CONTAINMENT <br /> VAULTS)WITH AUDIBLE AND VISUAL ALARMS. (23 CCR§2632,2634) 491.6 <br /> SECONDARY CONTAINMENT IS: ® a.DRY ❑ b.LIQUID FILLED ❑ c.PRESSURIZED ❑d.UNDER VACUUM <br /> -- <br /> x913-("--------- <br /> --.-_-.----__- _MODEL#_:_ EMC, _ <br /> PANEL MANUFACTURER: Gilbarco_ __ --- 4%W <br /> _ _-_____________ awl-9. MODEL#(S):- - 420--_ <br /> LEAK SENSOR MANUFACTURER: Veeder Root grNc1,F.WAT. TIS ANKfS)•(23 CCR§2643) awl"I <br /> 2.AUTOMATIC TANK GAUGING(ATG)SYSTEM USED TO MONITOR- 491.12 Owl-❑ <br /> PANELMANUFA(TURER: MODEL <br /> 4vn-14. x9115 <br /> _-- IN-TANK PROBE MANUFACTURER: _-- _- MODEL#(S): -- <br /> -_-_____ --_-4q).16 <br /> LEAK TEST FREQUENCY: ❑ a.CONTINUOUS ❑ b.DAILYINIGHTLY ❑ a WEEKLY 4W,17 <br /> ❑ d.MONTHLY ❑ e.OTHER( ify): ________--._----_-- <br /> -----PROGRAMMEDTESTS:------[j a.0.1 g.p.h. ❑ IT.0.2 g.p.h. ❑ c.OTHER(Specify): 49.19 <br /> 491-m <br /> ❑ 3.MONTHLY STATISTICAL INVENTORY RECONCILIATION(23 CCR§2646.1): 21 <br /> 4. <br /> ❑ 4.WEEKLY MANUAL TANK GAUGING(MTG)(23 CCR§2645). TESTING PERIOD: ❑ a.36 HOURS ❑ IT.60 HOURS 490-32 <br /> 49 23 <br /> 5.TANK INTEGRITY TESTING(23 CCR§2643.1): 490.24 <br /> TEST FREQUENCY: ❑ a.ANNUALLY ❑ b.BIENNIALLY ❑ c.OTHER(Specify): 49''2.5 <br /> 4w 26 <br /> ®99.OTHER (Specify): 36 month secondary containment testing 49o27 <br /> V.PIPE MONITORING IS PERFORMED USING THE FOLLOWING METHODS)(Check allUral apply) 4w zx <br /> 1.CONTINUOUS MONITORING OF PIPE/PIPING SUMPS)AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE AND <br /> VISUAL ALARMS. (23 CCR§2636) 491-29 <br /> SECONDARY CONTAINMENT IS:®a.DRY-❑b.LIQUID FILLED 0c.PRESSURIZED 5❑d.UNDER VACUUM^__ __-_. 4901 <br /> -_ <br /> --- , MODEL#: EMC <br /> PANEL MANUFACTURER:_GilberCo ---'------ x9135 <br /> -- -�----------------- MODEL#(S). 2_08__ <br /> LEAK SENSOR MANUFACTURER:_Veeder Root _-_�----- - - - 490-Mw <br /> a.YES ❑ T.NO <br /> PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP(i.e..TURBINE)SHUTDOWN. ® 491-35 <br /> FAILUREIDISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ®a.YES ❑b.NO <br /> FW_2.MECHANICAL LIVE LEAK DETECTOR(MLLE)THAT ROUTINELY PERFORMS 3.0 g.p-h.LEAK TESTS AND RESTRICTS OR SHUTS OFvF x <br /> PRODUCT_FLOW WHEN A LEAK IS DETECTED 2DS 3 CCR§2636) --_-_--_^_--_-.-_______-------------------- aw45N <br /> -_---- -- -49in MODEL#(S): Fik:. <br /> MLLD MANUFACTURER(S):Red Jacket a9o-59 <br /> z5.VISUALrwEM0NrrORING. TIME <br /> RONIC LINE LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS 3.0 g.ph.LEAK TESTS (23 CCR§2636) <br /> _ANUFACTURER(S) --.__._______-.-._ .i MODEL#(S): __-____ avli-iz <br /> AMMED IN LINE LEAK TEST: ❑ 1.MINIMUM MONTHLY 0.2 g.p.h. ❑ 2.MINIMUM ANNUAL 0.1 g.p.h. <br /> 4%143 <br /> ETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑n.YES ❑b.NOAILUREIDISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑a.YES ❑b.NO4w1-aaTEGRITY TESTING 4ww5 491.46 41947 <br /> R UENCY ® a.ANNUALLY ❑ b.EVERY 3 YEARS ❑ c.OTHER(S if ) 49-18 <br /> L PIPE MONITORING. 491.49 <br /> FREQUENCY ❑ a.DAILY ❑ b.WEEKLY ❑c.MIN.MONTHLY&EACH TIME SYSTEM OPERATED- <br /> •AIIaw.0 for muniwrin of unLurwJ cm.r me crcramr rva i in unl •r Hti g252NL5(M11p iw1-511 <br /> ❑ 6.SUCTION PIPING MEETS EXEMPTION CRITERIA[23 CCR§2636(x)(3)]. <br /> 7.NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 20,CHAPTER 6.7 TS CONNECTED TO THETANK SYSTEM <br /> 490.51 49452 <br /> 4915] <br /> ❑ 99.OTHER(Specify) <br /> UPCF UST-D(12120M)114 <br />
The URL can be used to link to this page
Your browser does not support the video tag.