Laserfiche WebLink
VICINITY MAP GENERAL CONDITIONS SHEET INDEX <br /> NO SCALE CONTACTS N <br /> ewvale RrJ Kom Ct 'n G---� o0m COORDINATION FIRE DISTRICT <br /> saaft <br /> 7fiVoW Gteil Dr _ OBa Or o yc%ulsDr.: 9g 1 COORDINATE THE WORK: DO NOT DELEGATE THE RESPONSIBILITY FOR PI COVER SHEET AND NOTES <br /> - INTurnsr Rd ETvmerRt i 1. COORDINATION- COORDINATION TO ANY SUBCONTRACTOR, FABRICATOR OR SUPPLIER. P2 SITE PLAN,TANK REMOVAL, & <br /> - - LODI FIRE DEPARTMENT <br /> Palm Ave �" .._ Colvrhia Or ale r» 2 RESOLVE DIFFERENCES OR DISPUTES CONCERNING COORDINATION, 210 WEST ELM STREET INSTALLATION NOTES <br /> Eme!ta Ave - +Denner Or '� INTERFERENCE, OR EXTENT OF WORK. LODI, CA. 95241 P3 TANK SECTION/SLAB PLAN <br /> Lours Avo r 3 USE LARGE-SCALE LAYOUT DRAWINGS OF OTHER AFFECTED WORK, TO <br /> 3 , , 209_333_6735 P4 TANK AND PIPING DETAILS <br /> i Palls Are pica ei or n COORDINATE, AND INTEGRATE THE WORK TO PREVENT <br /> CHECK, <br /> Por,est Ave a„` - isP5 MISCELLANEOUS DETAILS <br /> _. Sonora A,. INTERFERENCES. P6 <br /> TANK ORIENTATION/FITTING LAYOUT <br /> 4 COORDINATE WORK PERFORMED BY SBC AND OTHERS AS IT PERMIT If <br /> Murray St <br /> z �- INVOLVES THE EXECUTION OF THIS WORK. P7 TYPICAL TLS-350 INSTALLATION <br /> 'r_• lg ii n +3 c <br /> :> 5 COORDINATE DELIVERY AND STORAGE OF SBC FURNISHED EQUIPMENT ENVIRONMENTAL HEALTH DEPARTMENT PS PROJECT CLOSE OUT CHECK SHEET <br /> c° rc I AND FUEL FOR TESTING. <br /> ` A .gI Lo`cl:sf�ryl c! z " E4.ocAeto•d 9t lq <br /> Carlo 9yay -- ,�..�.- l fv=.+_ °+FT�ioTdlAv>.�.b+ CUTTING AND PATCHING SAN JOAQUIN COUNTY ENVIRONMENTAL HEALTH DIVISION <br /> x= A L} bst61 }, }"-' 304 EAST WEBER AVE. THIED FLOOR <br /> z z m {. E Lccust . 1 PATCHING SHALL SUCCESSFULLY DUPLICATE UNDISTURBED ADJACENT STOCKTON, CA 95202 <br /> n ....:? z 1E Elm '.t n i FINISHES, COLORS, TEXTURES AND PROFILES. <br /> n E Elm St 209-468-3420 <br /> - 2 COMPLY WITH LOCAL ORDINANCES AND THE REQUIREMENTS OF CCR TITLE <br /> z, m 1V f u e SI S r c - 8, INDUSTRIAL SAFETY ORDERS AND CAL OSHA REGULATIONS. DO NOT <br /> n r- Gi I n c a �? E Pima.St <br /> o g p CUT OR ALTER STRUCTURAL MEMBERS ITHOUT PRIOR WRITTEN APPROVAL <br /> o ' %VE)'k'I c EOsk St{ OF SBC. PERMIT <br /> d i <br /> f; v rn 4VIVvinpj y^r i n s` 3 PERFORM CUTTING, ASSOCIATED STRUCTURAL REINFORCING AND PATCHING IN <br /> s E m E+re smut.:lt A MANNER TO PREVENT DAMAGE TO OTHER WORK AND TO PROVIDE PROPER BUILDING DEPARTMENT <br /> Ave SURFACES FOR THE INSTALLATION OF MATERIALS, EQUIPMENT AND REPAIRS. <br /> - 11 ttlL 'dt AvaLotli ._.... PERFORM DEMOLITION WORK IN SUCH MANNER AS TO PREVENT DAMAGE TO CITY OF LODI COMMUNIi'f DEVELOPMENT DEPARTMENT <br /> N!!bow „ EXISTING FACILITIES TO REMAIN OR TO BE SALVAGED, AND TO PREVENT <br /> rn ,p ED °' n Ti. } ca INJURY TO PUBLIC AND WORKERS ENGAGED ON SITE UNDER THIS OR OTHER BUILDING INSPECTION DIVISION <br /> ry T w $ c, _ CONTRACTS. DEMOLITION DEBRIS SHALL NOT BE ALLOWED TO ACCUMULATE <br /> y „ „ Fr„5t 0 ee 221 WEST PINE STREET, P.O. BOX 3006 <br /> -- a m 6ture fit ON SITE. HAZARDOUS WORK SHALL NOT BE LEFT .STANDING OR HANGING <br /> o b g Connis6t ' 3 nom' - ECen m OVERNIGHT OR WEEKENDS. LODI, CA. 95241 <br /> y 'D B Tae3 Fla n ui � #.� ct a B 4 WHEREVER CUTTING AND REMOVAL OF PORTIONS OF EXISTING WORK IS 209-333-6714 <br /> E.T'c3! - -. $ INDICATED, SUCH WORK SHALL BE SAWN IN A MANNER THAT WILL PRODUCE <br /> ,`5 NTckay St & n. . <br /> H-ao'd 3l - S NEAT AND STRAIGHT LINES, PARALLEL TO ADJACENT SURFACES OR PLUMB PERMIT # <br /> CINIaOr w ut1 i FE" "onct5l 9de9le`} FOR VERTICAL SURFACES. GRIND SMOOTH RESULTING EDGES OF CONCRETE <br /> ^,atm G'al cR2 SLABS OR WALKS, <br /> p';nn'1 Dr Ch?uyS 5 NEATLY REMOVE EXISTING FINISH MATERIALS BACK TO CLEAN STRAIGHT LINE <br /> Efirhardt Dr o ON NEAREST SUPPORT IN ORDER TO FACILITATE INSTALLATION OF NEW <br /> 02001 MapQuz to.m,Ino.:02001 GDT, no. , E 2xne S) _ 3 MATERIALS, PATCHES OR REPAIRS. EXECUTE CUTTING AND DEMOLITION BY <br /> METHODS WHICH WILL PREVENT DAMAGE TO OTHER WORK AND WHICH WILL <br /> PROVIDE PROPER SURFACES TO RECEIVE INSTALLATION OF REPAIRS AND NEW <br /> WORK. <br /> N 6 KEEP AREAWAYS, WALKS, CORRIDORS AND STREETS FREE OF DIRT AND <br /> RUBBISH. <br /> 7 REPAIR OR REPLACE IMPROVEMENTS DAMAGED AS A RESULT OF THIS WORK <br /> ENVIRONMENTAL MANAGEMENT APPROVED UST INSTALLATION CONTRACTORS AT NO ADDITIONAL EXPENSE TO SBC. <br /> 8 PROVIDE WATER DAMS AND OTHER CONTAINMENT PROCEDURES, AS <br /> NECESSARY, FOR CONTROLLING WATER USED FOR CONCRETE SAW CUTTING. <br /> 1.MJK 2.TAIT ENVIRONMENTAL 3. CDM/PCI 4.FULLER EXCAVATING 5. BALCH PETROLEUM 6.FILNER CONSTRUCTION, INC. <br /> ATTN.: MIKE KISSICK ATTN.: JIM STREITZ ATTN.: CARY PARTON ATTN.: MIKE FULLER ATTN.: BILL BALCH ATTIC: STEVE WELGE <br /> 7303 SOMERSET BLVD. 701 N. PARKCENTER DR. 2030 WEST SEVENTEENTH ST. 3283 LUYUNG DR. RANCHO. 930 AMES AVE. 3633 SEAPORT BLVD. <br /> PARAMOUNT, CA. 90723 SANTA ANA, CA. 92705 LONG BEACH, CA. 90813-1084 CORDOVA, CA. 95742 MILPITAS, CA. 95035 W. SACRAMENTO, CA. 95691 <br /> (562) 663-1315 (714) 560-8639 (562) 432-7996 (916) 858-8300 (408) 942-8686 (916) 372-1985 <br /> (562) 663-1320fox (714) 560-8237 fax (562) 495-0695 fax (916) 858-8301 fox (408) 942-0131 (916) 372-0911 fax <br /> ENVIRONMENTAL CONSULTANT- SCOPE OF WORK GENERAL NOTES SCOPE OF NORK SUMMARY <br /> 1. CONTRACTOR TO FURNISH ALL LABOR, MATERIALS, EQUIPMENT AND SERVICES NECESSARY FOR THE I. INSTALL TEMPORARY 500 GALLON ABOVE GROUND DOUBLE WALL STEEL <br /> SATISFACTORY COMPLETION OF ALL WORK CALLED FOR OR REQUIRED BY THE DRAWINGS AND FUEL STORAGE TANK AND STEEL. f,PING TO EXISTING ENGINE ROOM. OR <br /> THE FOLLOWING SCOPE OF WORK WILL BE PERFORMED BY THE ENVIRONMENTAL CONSULTANT UNDER A SPECIFICATIONS. 19. ABOVE GROUND FUEL PIPING SHALL BE SECONDARILY CONTAINED AND MONITORED IF ANY OF THE BRING IN TEMPORARY GENERATOR SEE - - <br /> SEPARATE CONTRACT WITH SBC. 2. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE CURRENT APPLICABLE UNIFORM BUILDING FOLLOWING CONDITIONS EXIST: <br /> CODE, UNIFORM FIRE CODE, NATIONAL ELECTRICAL CODE, CALIFORNIA UNDERGROUND STORAGE TANK A) PIPING RUNS INSIDE IMPORTANT EQUIPMENT ROOMS, SUCH AS SWITCHING 2 AND REMOVE <br /> SOLVATED FUEL,0OPGALLON UUNDERGROUND FUEL STORAGE TANK <br /> NG. <br /> 7. ATTEND (1} METHODS OF PROCEDURE MEETING AT THE SITE PRIOR TO CONSTRUCTION. <br /> REGULATIONS, CAL-OSHA CONSTRUCTION SAFETY ORDERS AND ANY OTHER APPLICABLE STATE, CIN, OR <br /> COUNTY ORDINANCES. EQUIPMENT, CABLE VAULTS, ETC. <br /> 2. TRIPLE RINSE, TRANSPORT, AND DISPOSE OF FUEL STORAGE TANKS IN QUANTITIES SHOWN ON DRAWIN('S. 3. CONTRACTOR SHALL PROTECT ALL EXISTING FACILITIES TO REMAIN UNLESS NOTED OTHERWISE. CONTRACTOR B) PRESSURIZED FUEL PIPING RUNS 3. INSTALL NEW 8;000 GAL. UNDERGROUND TANK IN NEW LOCATION <br /> SHALL REPAIR OR REPLACE ANY EXISTING FACILITIES WHICH ARE DAMAGED BY THE CONTRACTOR'S AFTER NEW RETAINING WALL CONSTRUCTION (BY OTHERS) IS COMPLETED. �1 -� <br /> c <br /> 3. TRANSPORT AND DISPOSE OF RINSATE. OPERATIONS TO THE SATISFACTION OF THE SBC ENVIRONMENTAL MANAGEMENT (SBC). O) ENVIRONMENTALLY SENSITIVE AREAS (NEAR STORM DRAIN INLETS, SCHOOLS, ETC.) VU ARC\?,',..... <br /> D) PIPING EXPOSED ABOVE GROUND. � C>F':• �F` <br /> 4. THE EXISTENCE OF UNDERGROUND UTILITIES IS UNKNOWN. IT SHALL BE THE CONTRACTORS RESPONSIBILITY 4. INSTALL NEW UNDERGROUND AND WALL MOUNTED FUEL SUPPLY AND <br /> 4. TRANSPORT AND DISPOSE OF FUEL PIPING IN QUANTITIES SHOWN ON DRAWINGS. 20. THE CONTRACTOR IS TO COMPLY WITH ALL DUST CONTROL REQUIREMENTS AS SET FORTH BY THE FACILITY FtiC':C <br /> TO DETERMINE THE EXACT LOCATION(S) AND/OR EXISTENCE OF ALL UNDER-GROUND UTILITIES IN WORK RETURN PIPING, . <br /> a 5. COMPILE CLOSURE REPORT AS REQUIRED BY ENVIRONMENTAL MANAGER AND SEND COPIES TO LOCAL AGENCIES AREA. PRIOR TO CONSTRUCTION, CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT FOR FIELD SUPERVISOR OR HIS DESIGNATED REPRESENTATIVE WHEN DRILLING, CORING, OR OTHERWISE MAKING HOLES OR / <br /> PENETRATIONS INSIDE THE FACILITY BUILDING, INCLUDING SCREW HOLES FOR CONDUIT SUPPORTS, ETC. AS A 5. CONNECT NEW PIPING TO GENERATOR IN ENGINE ROOM. C# 192 {r <br /> AND SBC. MARKING OF UTILITY LOCATIONS. MINIMUM EFFORT, THE CONTRACTOR WILL CONTAIN AND COLLECT ALL DUST BY MEANS OF PLASTIC SHEET ' <br /> 5. CONTRACTOR SHALL APPLY AND PAY FOR ALL PERMITS REQUIRED FOR THE COMPLETION OF THIS PROJECT. ISOLATION OF THE WORK AREA AND VACUUMING THE DUST AS IT OCCURS. SEP 0 2061 ' <br /> ° CONTRACTOR TO SUPPLY CERTIFICATE OF INSURANCE, CITY BUSINESS LICENSE, EVIDENCE OF CONTRACTORS 6. INSTALL NEW VEEDER-ROOT TLS 350+ TANK MONITORING SYSTEM AND f •.,. . 10A�,. <br /> LICENSE AND ANY OTHER INFORMATION WHICH THE PERMITTING AGENCY REQUIRES FROM CONTRACTORS. OVERFILL ALARM. . <br /> E 21. NO WORK IS TO BE PERFORMED OVER THE SWITCH EQUIPMENT WITHOUT MOP (METHOD OF PROCEDURES). OF CpL\F��CX <br /> n 6. GENERAL CONTRACTOR SHALL NOTIFY THE ENGINEER PROMPTLY IF SITE CONDITIONS OR DIMENSIONS <br /> H7. REMOVE TEMPORARY TANK OR GENERATOR AND REPAIR ANY PAVING <br /> DISAGREE WITH INFORMATION SHOWN ON THESE DRAWINGS. WORK IS NOT TO PROCEED UNTIL SUCH <br /> o DIFFERENCES ARE RESOLVED. AND/'OR CONCRETE DAMAGED OR REMOVED DURING CONSTRUCTION. REVISIONS / AUTHORIZATIONS <br /> b 7. CONTRACTOR SHALL COORDINATE WITH THE ENVIRONMENTAL CONSULTANT AND SBC FOR DISPOSAL OF TANK, <br /> N PIPING AND RELATED EQUIPMENT AND THE TESTING FOR CONTAMINATION. Na. RensroNs / AUTHORIzaTans DATE ar <br /> ^0 8. CONTRACTOR TO REMOVE TANK AND LOAD ONTO TRUCK IN ACCORDANCE WITH LOCAL REQUIREMENTS. <br /> to 9. SBC ENVIRONMENTAL CONSULTANT SHALL BE RESPONSIBLE FOR ANY SOIL/GROUNDWATER SAMPLING AND SUBMITTED FOR PERMIT 7/17/01 MED <br /> E ANALYSIS. ENVIRONMENTAL CONSULTANT SHALL TRANSPORT AND DISPOSE OF TANK, PIPING AND ANY i CHANGE UNDERGROUND PIPING SPECIFICATION 5/29/01 ME6 <br /> 1= CONTAMINATED SOIL AND GROUNDWATER. CONTRACTOR SHALL DISPOSE OF CLEAN SOIL, CONCRETE DEBRIS <br /> AND MISCELLANEOUS EQUIPMENT, <br /> a 10, CONTRACTOR SHALL PROVIDE A DETAILED METHOD OF PROCEDURE (M.O.P.) TO SBC FOR APPROVAL PRIOR <br /> TO START OF CONSTRUCTION. <br /> 0 CONTACT INFORMATION; 11. CONTRACTOR SHALL SUPPLY SBC WITH A DETAILED WORK SCHEDULE AND UPDATE PROGRESS AND/OR <br /> USYDNEY GEELS - IT CORPORATION CHANGES ON A WEEKLY BASIS. NOT FOR GENPROPRIETARY SBC INFORMATION <br /> N 4005 PORT CHICAGO HIGHWAY GENERAL USE OR DISCLOSURE OUTSIDE OF SBC <br /> 12 CONCORD, CA 94520 12. CONTRACTOR SHALL PROVIDE THREE SETS OF SUBMITTALS ON ALL EQUIPMENT TO THE ENGINEER PRIOR TO ENVIRONMENTAL MANAGEMENT UNDER EXEMPTIONS SET FORTH IN <br /> START OF CONSTRUCTION. THE CALIFORNIA PUBLIC RECORDS ACT. THIS INFORMATION MAY <br /> ONLY BE USED BY AUTHORIZED PERSONNEL OF THE LOCAL <br /> a (925) 288-2119 PHONE 13. CONTRACTOR SHALL BE RESPONSIBLE FOR SUPPLYING THREE COMPLETE SETS OF OPERATION, MAINTENANCE GOVERNMENT AGENCY IN CONNECTION WITH APPLICATION FOR <br /> -°, (925) 827-2029 FAX AND TEST DATA, WHICH SHALL INCLUDE: AND ITORAND AUTHORIZATIONS FOR BUILDINGS, CONSTRUCTION, <br /> E (925) 988-5386 PAGER <br /> in A) ALL MANUFACTURER'S LITERATURE, SUBMITTAL DATA COPIES, INSTALLATION, <br /> s' 24 HOUR EMERGENCY HOTLINE - FOR AFTER-HOURS EMERGENCIES ONLY - (800) 537-9540 OPERATION AND MAINTENANCE DATA ON ALL EQUIPMENT AND DEVICES INSTALLED. DRAWINGS PREPARED FOR <br /> a , THIS IS TO INCLUDE TANKS, SENSORS, WELLS, PIPING, PUMPS, DOUBLE / <br /> SCOPE. CONTAINMENT SYSTEM, SUMPS, AND ALL OTHER INSTALLED ACCESSORIES. ENVIRONMENTAL MANAGEMENT <br /> 1. TRIPLE RINSING OF TANK(S) AND TRANSPORT AND DISPOSE OF RINSATE. B) ALL TEST RESULTS INCLUDING BUT NOT LIMITED TO PRESSURE AND/OR LEAK TESTING. <br /> u, 2. TRANSPORT AND DISPOSAL FOR TANK(S) IN QUANTITIES SHOWN ON DRAWINGS. <br /> PACIFIC REGION <br /> 3. TRANSPORT AND DISPOSAL FOR PIPING/ DISPENSERS QUANTITIES SHOWN ON DRAWINGS. C) ALL PERMITS, COPIES OF SIGNED-OFF PERMITS FROM ALL AGENCIES INVOLVED. <br /> i 4. COMPLETE CLOSURE REPORTING AS REQUIRED BY OVERSIGHT AGENCY AND EM, DISTRIBUTE COPIES TO D) COPY OF CORRESPONDENCE WITH VARIOUS AGENCIES CONCERNING THIS PROJECT. <br /> PROJECT TIME€ <br /> APPROPRIATE PARTIES. PACIFIC BEIM, FACILITY, E) ALL DOCUMENTS AND DATA SHALL BE INSTALLED IN A RING BINDER AND EACH <br /> cp SECTION APPROPRIATELY IDENTIFIED. OUTSIDE COVER SHALL CLEARLY IDENTIFY <br /> n � JOB LOCATION AND DATE. <br /> 124 W. ELM STREET <br /> N <br /> F) AS-BUILT DRAWINGS. LODI, CA <br /> 0,1 14, STOCKPILE OF DIRT SHALL BE COVERED COMPLETELY WITH PLASTIC TARP. ANCHOR AND SECURE <br /> N <br /> CONTRACTOR REQUIREMENTS: PLASTIC TARP FIRMLY TO PROTECT FROM THE ELEMENTS. LODICA01 UE020 <br /> b 6 1. CONTRACTOR MUST NOTIFY ENVIRONMENTAL CONSULTANT AT LEAST 48 HOURS IN ADVANCE TO <br /> 5 - SCHEDULE ACTIVITIES. 15. ALL ELECTRICAL WORK TO BE DONE IN COMPLIANCE WITH CHAPTER 5, ARTICLES 500-50 AND 514 SHEET TniE <br /> iO.O 2, CONTRACTOR MUST PROVIDE A COPY OF THE REMOVAL PERMIT, TANK INSTALL PERMIT (AS APPLICABLE), OF THE NATIONAL ELECTRIC CODE. SEAL ALL CONDUITS AS REQUIRED UNDER THE CODE. <br /> jh aSTATE OF CALIFORNIA FORMS A AND B (FOR EACH TANK) (AS APPLICABLE) TO ENVIRONMENTAL 16. NO GALVANIZED PIPE OR FITTINGS FOR DIESEL SERVICE WILL BE ALLOWED. STAND-BY GENERATOR SUCTION SYSTEM <br /> m CONSULTANT AT TIME OF TANK REMOVAL. COVER SHEET AND NOTES <br /> �1z 3. CONTRACTOR MUST ADVISE CONSULTANT OF THE MOP OR FORWARD INFORMATION REGARDING ANY 17. ALL CONDUIT SHALL BE PVC COATED PER P-2, RIGID TYPE WITH THREADED CONNECTORS AND BE <br /> w . ACCESS CONSTRAINTS FOR TRUCKS. CONTRACTOR SHOULD BE ADVISED OF TIME AND LOCATION CHOSEN FOR WRAPPED FOR CORROSION PROTECTION TO A POINT ABOVE GROUND LEVEL. NO DIE CAST, PVC, OR ESTIMATE/ ROUTINE ORDER. <br /> 'o MOP MEETING AT LEAST ONE A WEEK PRIOR TO ITS SCHEDULED TIME. PLASTIC ELECTRICAL CONDUIT OR FITTINGS SHALL BE USED. USE ONLY STEEL CONDUIT FITTINGS. DATE- 5/2501 SCALE AS NOTED <br /> DRAWN BY: SOW CHECKED BY: MED <br /> i 18. NEW TANKS AND PIPING TO BE TESTED IN ACCORDANCE WITH APPLICABLE REGULATIONS AND SBC AUTHORIZATION: <br /> SPECIFICATIONS. ARCET6CTCRR • ENGDVEBBRING • T.MONWIT'AL SERVIL'(S SHEET: 1 OF. 8 M1EErs FSHEErNO.1137 N. Kc00WELL BLVD. PETALUMA, CA 94954 (707) 765-1660 SBC ORAMNG NO.: <br /> OtmO/ DIC JOHN W. JOHNSON, ARCHITECT JAMES H. RAY, CIML ENGINEER <br />