Laserfiche WebLink
I" FUEL OIL SUPPLY NOTES <br /> & 1 1/2" FUEL OIL RETURN <br /> 1. ALL UNUSED TANK OPENINGS SHALL BE TIGHTLY SECURED WITH PIPE PLUGS AND SHALL BE COVERED WITH A FIBERGLASS CAP <br /> (HAT) INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS UTILIZING WET RESIN. ANNUALR TO BE AT FILL END (LOW <br /> END) OF TANK. <br /> 2. ALL TANK RISERS TO BE FACTORY SCOTCHKOTE #206N FUSION BONDED EPDXY COATED SCH. 40 BLACK STEEL PIPE. FIELD <br /> 12 PATCH ALL EXPOSED OR DAMAGED AREAS & FITTINGS WITH SCOTCH #312 COATING. (MATERIAL SUPPLIER: FLETCHER COATING CO. <br /> 2" SCH. 40 BLACK STEEL714/637-4763). ALL VERTICAL RISER THREADS SHALL BE WRAPPED IN FIBERGLASS 3" MIN. ABOVE EXPOSED THREADS IN <br /> NOTE: ALL FILL BOXES HOLD THIS DIMENSION ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. <br /> A 5 PRIMARY & 3" FIBERGUSS TO BE INSTALLED ON TO ASSURE (5) GALLON SECONDARY VENT 3. TANKS SHALL BE TESTED AND INSTALLED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AS WELL AS LOCAL <br /> CENTERLINE OF TANK CAPACITY OF SPILL <br /> B ORDINANCES. <br /> 15 COLLECTOR 4. ALL CONTAINMENT BOX ASSEMBLIES SHALL BE FIBERGLASSED TO TANK RING AND MUST BE HYDROSTATIC TESTED, <br /> C 5. TANKS TO SLOPE DOWN TOWARD FILL END AND ANNULAR SPACE SENSOR 1/2" MIN., 2" MAX., MEASURED OVER THE LENGTH <br /> ❑ 6F TANK,CONDU TS TRANSIT TO DETERMINE SLOPE. <br /> TO SEAL-OFFS ALLPER LATEST EDITION OF THE NATIONAL ELECTRIC CODE. ALL J-BOXES TO BE EXPLOSION <br /> E PROOF. KILLARK #GRSS-20R CROUSE-HINDS GUA SERIES. ORIENT ALL J-BOXES SUCH THAT THE SCREW LID IS ACCESSIBLE <br /> WITHIN THE FILL BOX OR CONTAINMENT SUMP. <br /> 7. ALL PENETRATIONS OF THE SUMP BOXES TO BE SEALED BY THE APPROPRIATE SIZE WESTERN FIBERGLASS GROMMET OR <br /> AMERICAN LINING COMPRESSION FITTING <br /> "> 8. USE CABLE CONNECTOR FITTINGS (CROUSE-HINDS CG B OR EQUIVALENT) AT MONITOR & LEVEL GAUGE CABLE CONNECTIONS TO <br /> ❑ N J-BOXES & PIPE FITTINGS IN SUMP BOXES. <br /> PLAN VIEW SHOWS SUGGESTED PIPING 1" BALL 13 9. ALL UNDERGROUND CONDUITS AND CONDUITS INSTALLED OUTDOORS TO BE PVC COATED RIGID. ALL CONDUITS INSTALLED INSIDE <br /> BELOW, SOME PIPING HAS BEEN DELETED <br /> ORIENTATION. ELEVATION VIEW VALVE BUILDING MAY BE EMT. ALL CONDUIT FITTINGS TO BE COMPRESSION TYPE. <br /> FOR CLARITY 10. PRIMARY & SECONDARY PIPING FOR VENT LINE TO BE SCH. 40 SCOTCHKOTED BLACK STEEL (PRI.) & AMERON DUALOY 3000L <br /> FIBERGLASS (SEC.). REDUCING BOOT IN CONTAINMENT SUMP TO HAVE TEST PORT. <br /> NOTE: 11. BULKHEAD REDUCERS IN CONTAINMENT SUMPS, PIPING VAULTS & TRENCHES TO HAVE TEST PORTS, <br /> ORIENT 12" ACCESS OPENING IN ITEM O6 3 <br /> OVER SUMP SENSOR J-BOX. 4 12, ALL CONCRETE TO BE 6 SACK MIX, 2500 PSI (MIN.) AT 28 DAYS, <br /> SUMP SENSOR MUST BE ABLE TO 13. VENT PIPING TO SLOPE DOWN TO UNDERGROUND TANK 1/8" TO 1/4" PER FOOT MIN. <br /> BE EASILY REMOVED VERTICALLY. PLAN VIEW 14. ALL EQUIPMENT, HARDWARE AND SYSTEM COMPONENTS MUST BE INSTALLED IN STRICT CONFORMANCE WITH MANUFACTURER'S <br /> INSTRUCTIONS AND SPECIFICATIONS. <br /> 15. INSTALL PRODUCT TAG IN FILL BOX, ATTACHED TO RISER. <br /> IMPORTANT SUCTION SYSTEM MATERIAL LIST <br /> MAINTAIN SLOPE AWAY FROM ALL MANWAY <br /> COVERS 3" IN 6' OR TO EDGE OF SLAB O1 8,000 GALON DOUBLE WALL STEEL, FIBERGLASS COATED COMPOSITE TANK. MODERN <br /> (WHICHEVER IS CLOSER) TOP OF LID TO GAUGE PROBE RISER WELDING, ENMRO 16. <br /> TOP EDGE OF <br /> ADAPTOR OTANK & PIPING LEAK MONTOR/ELECTRONIC PRODUCT LEVEL GAUGE CONTROL BOX <br /> WITH GAUGE PROBE & 2 SUMP SENSORS. ALL PROBES USED SHOULD BE FOR <br /> 5 8 8 16 (TYP.) 10 5 8 7 9 17 SET BOX TO ALLOW <br /> LIQUID DETECTION. VEEDER-ROOT #TLS-350 WITH PRINTER. <br /> ACCESS TO J-BOX LID 01 1/2" DOUBLE POPPET FOOT VALVE & EXTRACTOR ASSY. OPW #86 & 233E-4240 <br /> FOR LIQUID SENSOR OR E-MCO A439-005 AND A677-003 <br /> •� iv MAINTENANCE <br /> #4 ® 12" O.C. BOTH WAYS ®VENT LINE 4"0"x2" 150# MALLEABLE IRON EXTRACTOR FITTING WITH PLUG. <br /> ° ° _ ° — • - �— — — ° — — — z <br /> &2) PIECE CONTNNMENT SUMP WITH FIBERGLASS KIT PHIL-TITEFG-4261-S-2. <br /> — — — — — — — — — — — — — — —�— — — — • — — — — — ° °O °p SUMPS TO BE INSTALLED BY PhL-TITE ENTERPRISES USING CHOP GUN <br /> N � <br /> (530-223-7400), <br /> SLOPE SIDES OF TANK <br /> HOLE USE SHORING 036" DIA. MANHOLE. WITH ONE 13" ACCESS COVER PHIL-TITE #iC 3600-DAO. <br /> FOR ALL <br /> TANK EXCAVATIONS WATERTIGHT SUMP BACKFILL LEVEL <br /> \\ \ 036" DIA. SPILL CONTAINMENT MANHOLE WITH 5 GALLON SPILL BUCKET. PHIL-TRE <br /> \//\\//\\// oa <br /> IN ACCORDANCE WITH CAL/OSHA �— SHIELD ADAPTOR (TYP.) \ #SC-3600-SCA-2.-��\-��\-� m <br /> CONSTRUCTION SAFETY ORDERS. 2 1/2" THREADED PVC o ? <br /> I" C I �_ <br /> 1" C. 3/4" C. DT' <br /> CAP HAND-TIGHT ONLY �j ®WATERTIGHT SUMP SHIELD ASSEMBLY PhIL-TITE 4FG-3433-WTSS INCLUDES <br /> TO LEAK MONITOR/LEVEL GAUGE CONTROL 4WTC-1300 WTR-1013 VTC-8000 & WTR-0608 INSTALL PER MFR. INSTALLATION <br /> PANEL. (AFTER BUILDING PENETRATION, 3 10" LG. (OR AS NEEDED) FoEL m INSTRUCTIONS. <br /> 3/4" CONDUIT MAY BE USED) FACTORY THREADED x <br /> 4 NIPPLE, PROVIDED BY C.C. �� O9 4" TOP SEAL FILL CAP & SWIVEL ADAPTOR. MORRISON BROS. 305C (CAP) <br /> RISER FROM TANK o PHIL-TITE ENTERPRISES #SWF-100 (ADAPTOR). " .-c,�Ll ItCyV <br /> O DISCRIMINATING 72 19 1p CONDUIT PENETRATION-SEALING GROMMET, AMERICAN LINING COMPRESSION FTG. OR <br /> SENSOR LOCATED AT 73 CONCRETE SLAB MUST m OWESTERN FIBERCLA55 (MUST WITHSTAND HYDROSTATIC TESTING . "6 ��•: <br /> SUMP LOW POINT 2 I EXTEND 12' PAST11 ) <br /> EXCAVATION PERIMETER ALL �O 201 i Vr <br /> g 2 1/2" PLUG IN UNUSED ANNULAR I 2 1/2" SCH. 40 AROUND it 18" DIA. X 12" SKIRT LOCKABLE &. WATERTIGHT FILL BOX. PHIL-TTE #M1800 r <br /> SEP 'T 2ml <br /> o SEE NOTE (1)� 18 STEEL PIPE—SCOTCHKOTED BLACK 12 BULKHEAD FITTING AND REDUCING BOOT. WEAVER #BSER - 37x24 10.0 ;✓'C <br /> 13 <br /> gT`UF CAL\ <br /> E m ® s m 2" z 24" FEMALE x MALE SWIVEL STAINLESS BRAID FLEX CONNECTOR TITEFLEX� <br /> X _ < <br /> 110165-32-0240. ilS <br /> g I I NOTE: FOR OPTIMUMI INSTALLATION O REVISIONS / AUTHORIZATIONS <br /> o I I RESULTS MANUFACTURER SUGGESTS I DISCRIMINATING 14 4" ALUMINUM DROP TUBE QPW #61 T SERIES <br /> USING ONLY FACTORY THREADED PLUG SENSOR LOCATED NT0 <br /> I NIPPLE RISERS I I I I SUMP LOW POINT 15 RETURN UNE 4"0"x2" 150# MALLEABLE IRON EXTRACTOR FITTING WITH PLUG. OPW <br /> N0. REVISIONS / AUTHORIZ70NS DATE BY <br /> a pA I I I I I I qI 233-4420. <br /> EXTRACTOR CAP UNIVERSAL #412 OR EBW #760.i6 SUBMITTED FOR PERMIT 7/17/01 MED <br /> E I I I I I I I <br /> 1 CHANGE UNDERGROUND PIPING SPECIFICATION 8/29/01 MED <br /> E I I 1 1/2" SCH. 40 17 17 OVERFILL VALVE, EMCO WHEATON 01100. <br /> a <br /> BUCK STEEL PIPE 18 UNIVERSAL SENSOR MOUNTING KIT, VEEDER-ROOT #330020-012. <br /> PROPRIETARY SBC INFORMATION <br /> 14 NOT FOR GENERAL USE OR DISCLOSURE OUTSIDE OF SBC <br /> �^ I ENVIRONMENTAL MANAGEMENT UNDER EXEMPTIONS SET FORTH IN <br /> I I I THE CALIFORNIA PUBLIC RECORDS ACT. THIS INFORMATION MAY <br /> FILTER FABRIC ! I ONLY BE USED BY AUTHORIZED PERSONNEL OF THE LOCAL <br /> (WHEN REOb WITH UNSTABLE GOVERNMENT AGENCY IN CONNECTION WITH APPLICATION FOR <br /> oSOIL AND/ OR HIGH WATER / <br /> N / PER ITS AND AUTHORIZATIONS FOR BUILDINGS, CONSTRUCTION, <br /> E ABLE CONDITIONS) AND OR ZONING CHANGES. <br /> \�� b /� WESTERN FIBERGLASS MATERIAL LISP (THIS SHEET ONLY) DRAWINGS PREPARED FOR <br /> 3 1 1/2" PRIMARY FLEX PIPE - (RETURN LINE) - P14500 ENVIRONMENTAL MANAGEMENT <br /> 1 2 45 II // O 1" PRIMARY FLEX PIPE - (SUPPLY LINE) - P13500 PACIFIC REGION <br /> / 4" FLEX IBLE SECONDARY CONTAINMENT PIPE (WESTERN FIBERGLASS) - P14526 PROJECT TIRE: <br /> DO BULKHEAD FITTING - AC843 PACIFIC BELL FACILITY <br /> 7 <br /> SENSORPLUG FORTWITH 2USED TANK 1/2" SOLID <br /> _ _ - _ / " 0 REDUCING BOOT - P14677 124 W. ELM STREET <br /> SQUARE HEAD PLUG. (SEE NOTE 1) <br /> _ LODI, CALIFORNIA <br /> �\\ SLOPE TANK DOWN TOWARD FILL - / / LODIf A01 <br /> Y' e DEADMAN..NOT SHOWN `FOR .CLARITY. - END 1/2" MIN., 2" MAX. MEASURED 0744390 420 - UE020 <br /> 5 \\-! LEAK SENSOR . SHEET TME. <br /> — — — — OVER LENGTH OF THE TANK - - — — — — STAND-BY GENERATOR SUCTION SYSTEM <br /> -1 T� I I -� -1 1-� -1 1=1 11- TANK SECTION/SLAB PLAN <br /> o CLEAN, WASHED NATIVE t 2. TYP ESTIMATE/ ROUTINE ORDER: DQE: 5/25/01 SCW.E, AS NOTE) <br /> w I COMPACTED SAND SOIL DRAWN BY: SOW CHECKED BY.. MED <br /> BED AND <br /> BACKFILL SBC AUIHORPATION: SHEET: 3 W': 8 SHEETS SHEET NO. <br /> ARC�TBCfURB • &NGQ188RING • &IVV@ONYfl1'fAL 36RYICFS <br /> 1 TYPICAL TANK PRODUCT SUCTION SYSYTEM 1177 N. MAOWIIL BLVD. PE ALUMA CA 9H. R . CIVIL <br /> 785INEER sec ORAWNC NO.: P3 <br /> SCALE: NONE fhDU! INC JOHN W. JOHNSON, ARCHITECT JAMES H. RAY, CIVIL ENpNEER <br />