My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELM
>
230
>
2300 - Underground Storage Tank Program
>
PR0231330
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/16/2021 11:24:16 PM
Creation date
11/4/2018 4:53:40 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231330
PE
2361
FACILITY_ID
FA0003964
FACILITY_NAME
LODI PUBLIC SAFETY BUILDING
STREET_NUMBER
230
Direction
W
STREET_NAME
ELM
STREET_TYPE
ST
City
LODI
Zip
95240
APN
04303109
CURRENT_STATUS
02
SITE_LOCATION
230 W ELM ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\ELM\230\PR0231330\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
4/3/2013 8:00:00 AM
QuestysRecordID
87072
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
l MED PROGRAM CONSOLIDATED FORM ANx: rw0133003 <br /> ✓ I PR#: PRO231330 <br /> UNDERGROUND STORAGE TANKS -TANK PA I FAC#: FA0003964 <br /> y 3 03 (two pages per tank) <br /> TYPE OF ACTION ❑ 1NEW SITE PERMIT ❑ 4AMENDED PERMIT.y it vny) ❑ SCHANGE OF INFORMATION ❑ 67EMPORARY SITE CLOSURE <br /> _ " .. ;' ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ❑3RENEWAL PERMIT (SP=eJrS TOrbcei us Nvl (*drytgsw-fn loci ry) <br /> A ❑8TANK REMOVED 430 <br /> BUSINESS NAME($men FACRITY NAME Q DBA-Poing Bwiros As) FACILITY ID: pR#: t <br /> LODI PUBLIC SAFETY BUILDING 31 <br /> FA00039f I PR0231330 <br /> LOCATION WITHIN SITE(o W) 230 W ELM ST,LODI <br /> al <br /> PHONE <br /> 1.TANK DESCRIPTION(A scaled plot plan with the location otihe UST syskm including bw7dings and lanMmrks shop be suhrmned to Ole Io;al agelcy.) <br /> TANK ID# rank#: 3 4J2 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK <br /> ❑Yes ❑No 434 <br /> TA0133003 <br /> PERKINS WELDING SACRAMEN 1r Yo',®pw w p g m,nm�np„a ea <br /> DATE INSTALLED,YEAR/MO) 435 TANK CAPACITY IN GALLONS 4336 NUMBER OF COMPARTMENTS <br /> 43) <br /> 12.000 <br /> ADDITIONAL DESCRIPTION(Fwloul nc Wy) <br /> 439 <br /> H.TANK CONTENTS <br /> TANK USE 439 P OLEUM TYPE <br /> ® 1.MOTOR VEHICLE FUEL la.REGULAR UNLEADED ❑ 2.LEADED ❑ 5.JET FUEL sW <br /> pr�akra wnPwe earolean rSPe) y <br /> ❑ Ib.PREMNM UNLEADED t�1p 3.DIESEL ❑6.AVIATION FUEL <br /> ❑2.NON-FUEL PETROLEUM ❑ Ic MIDGRADE UNLEADED <br /> ❑ 3.CHEMICAL PRODUCT ❑ 4.GASOHOL ❑ 99.OTHER <br /> COMMON NAME(m xamsmn M.leiaw mvmnryg8e) 141 CAS#(aom xasasmw Matcmis lmeto page) 443 <br /> F1 4.HAZARDOUS WASTE <br /> (IrcIa UsMOa) <br /> ❑95.UNKNOWN <br /> ID.TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1.SINGLE WALL ❑3.SINGLE WALL WITH ❑ 5.SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (r,Txkercimnony) EXTERIOR MEMBRANE LINER 095.UNKNOWN <br /> ®2.DOUBLE WALL ❑ 4.SINGLE WALL IN VAULT [:199.OTHER <br /> TANK MATERIA.-prin s,tank ® 1.BARE STEEL ❑ FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑95.UNKNOWN a44 <br /> lChxk oM/mnnnN) ❑2.STAINLESS STEEL E] STEEL CLAD W/FIBERGLASS ❑ 8.FRP COMPT®LE W/I00%METHANOL <br /> REINFORCED PLASTIC(FRP) <br /> ❑ 99.OTHER <br /> TANK MATERIAL-secondary taM LBARE STEEL ❑ ERGLASS/PLASTIC ❑ S.CONCRETE ❑ 95.UNKNOWN 445 <br /> (caeaaK can Dory) ❑ 2.STAINLESS STEEL 4.STEEL CLAD W/FIBERGLASS ❑ 8.FRP COMPTIBLE W/100%METHANOL 7 <br /> REINFORCED PLASTIC(FRP) ❑ 10.COATED STEEL ❑ ".OTHER , <br /> ❑ 5.CONCRETE <br /> TANK INTERIOR LINING ❑ I.RUBBER LINED 3.EPDXY LINING <br /> OR COATING ❑ ❑ 5.GLASS LINING ❑95.UNKNOWN H6 DATE INSTALLED 447 <br /> (CMt onei�®y) ❑ 2 ALKYD LINING ❑4 PHENOLIC LINING ®6 UNLINED ❑ 99.OTHER <br /> (Pe lonl neaJy) <br /> OTHER CORROSION I MANUFACTURING CATHODIC ❑ 3FIBERGLASSREINFORCED PLASTIC ❑95 UNKNOWN H8 DATE INSTALLED M9 <br /> PROTECTION IF APPLICABLE PROTECTION <br /> (CMsko ..nl3.) ❑ 4 IMPRESSED CURRENT El "OTHER <br /> [:12 SACRIFICIAL ANODE (Fabmt nc e8y) <br /> SPILL AND OVERFB.L/ YEAR NSTALLE450 TYPE Oo .c Y) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> (Chmkae mt qty) L`-1/ SPILL CONTAINMENT ❑ i ALARM FILL TUBE SHUT OFF VAL` <br /> RQ 2DROPTUBE ❑ 2BALL ❑ 4EXEMPT <br /> ❑ 3STRIKER PLATE FLOAT <br /> IV.TANK LEAK DETECTION(A a�iplinnormemonboshgps�.nswn x simmiueem Iactwl egmsY7 <br /> IF SINGLE WALL TANK(�all wtappy) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> I VISUAL(EMSED PORTION ONLY) (arck�ttao only) <br /> ❑ ❑ SMANUAL TANK GAUGING <br /> ❑ 2 AUTOMATIC TANK GAUGING(ATG) ❑6VADOSE ZONE ❑ I VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑ 3 CONTINUOUS ATG ❑7 GROUNDWATER ®2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑4 STA71SUCAL NVENTORY RECONCU IATION ❑ 8 TANK TESTING <br /> (SIR)BIENNIAL TANK TESTING 990THF32 E]3 MANUAL MONITORING <br /> ❑ <br /> V.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MOMAY) 455 ASTUTATED QUANTITY OF SUBSTANCE REMAINING 456 1 TANK FILLED WITH VERT MATERIAL? 457 <br /> ❑Yes ❑ No <br /> UPCF(12/99 revised) <br />