My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1992 - 2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
88 (STATE ROUTE 88)
>
14000
>
2300 - Underground Storage Tank Program
>
PR0231631
>
COMPLIANCE INFO_1992 - 2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 9:21:32 AM
Creation date
11/4/2018 5:25:21 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1992 - 2006
RECORD_ID
PR0231631
PE
2361
FACILITY_ID
FA0000091
STREET_NUMBER
14000
Direction
E
STREET_NAME
STATE ROUTE 88
City
LOCKEFORD
Zip
95237
CURRENT_STATUS
01
SITE_LOCATION
14000 E HWY 88
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\HWY 88\14000\PR0231631\COMPLIANCE INFO 1992 - 2006 .PDF
QuestysFileName
COMPLIANCE INFO 1992 - 2006
QuestysRecordDate
3/16/2017 4:23:12 PM
QuestysRecordID
3355446
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
295
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page 5 of 8 <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: U Sump Manufacturer N Industry Standard U Professional Engineer <br /> U Other(Specify) <br /> Test Method Used: 0 Pressure 0 Vacuum X1 Hydrostatic <br /> 0 Other(Spec) <br /> Test Equipment Used: Caldwell Equipment Resolution: <br /> Sump# 1 -R Sump# 2-S Sump# 3-P Sump# <br /> Sump Diameter. n 4911 4911 <br /> Sump Depth: 45" 4511 4411 <br /> Sump Material: —Fiberglass iber lass Fiberglass <br /> Height from Tank Top to Top of 1611 1 5" 1 6" <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 1811 1 8" 18" <br /> Electrical Penetration: <br /> Condition of sump prior to testing: Dirty/Dry in /Dry Dirt Dr <br /> Portion of Sump Tested' 1811 1 7" 1 8" <br /> Does turbine shut down when IXYes U No U NA <br /> sump sensor detects either product INYes U No U NA XJ Yes UNo UNA U Yes U No U NA <br /> or water? <br /> Turbine shutdown responsedmez' 2 seconds 2 seconds 2 seconds <br /> Is system programmed for fail-safe LXYcs U No U NA XYes UNo UNA Xl Yes UNo UNA U Yes UNo UNA <br /> shutdown?' <br /> Was fail-safe verified to be tXYes UNo UNA XYrs UNo UNA XlYes UNo UNA UYes UNo UNA <br /> operational?' <br /> Wait time between applying t i 1 hr.. <br /> pressure/vacuum/water and starting z hr. hr. , <br /> test: <br /> Test Start Time: 10:4 5 10:0 0 10 :3 0 <br /> Initial Reading(R,): 0 0 <br /> Test End Time: 11 - 15 10. 30 10:30 <br /> Final Reading(R,): -,05 -.025 -.03 <br /> Test Duration: t hr. 1 hr. i hr.. <br /> Change in Reading(P)-R,): .05 . 025 .0 3 <br /> Pass/Fail Threshold or CAteria: -2 . 5"24 hrs. 1 .25"24 hrs. -1 . 5"24 hrs. <br /> Test Result: U Pass IXF211 U Pass XI Fall U Pass INF811 U Pass U Fall <br /> Was sensor removed for testing? IXYes U No U NA NYes UNo UNA XI Yes UNo UNA U Yes U No U NA <br /> Was sensor properly replaced and IXYes UNo UNA tit Yes UNo UNA XJ Yes UNo UNA U Yes U No U NA <br /> verified functional after testing?, <br /> Comments- (include information on repairs made prior to testing, and recommended follow-up forfailed tests) <br /> If the testing method does not test the entire depth of the sump,specify how much of the sump was tested. Methods not testing the <br /> entire sump should only be used if the monitoring system provides fail-safe turbine shutdown. (See SWRCB LO-160) <br /> 2 With the submersible pump running,place the sensor in product(discriminating sensors should also be placed in water). The time <br /> between placing the sensor in product and the turbine shutting down is the response time. This should be done if the secondary <br /> containment testing method used does not test the entire volume of the sump. <br /> This information is not needed if the entire sump is tested. <br />
The URL can be used to link to this page
Your browser does not support the video tag.