My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1992 - 2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
88 (STATE ROUTE 88)
>
14000
>
2300 - Underground Storage Tank Program
>
PR0231631
>
COMPLIANCE INFO_1992 - 2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 9:21:32 AM
Creation date
11/4/2018 5:25:21 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1992 - 2006
RECORD_ID
PR0231631
PE
2361
FACILITY_ID
FA0000091
STREET_NUMBER
14000
Direction
E
STREET_NAME
STATE ROUTE 88
City
LOCKEFORD
Zip
95237
CURRENT_STATUS
01
SITE_LOCATION
14000 E HWY 88
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\E\HWY 88\14000\PR0231631\COMPLIANCE INFO 1992 - 2006 .PDF
QuestysFileName
COMPLIANCE INFO 1992 - 2006
QuestysRecordDate
3/16/2017 4:23:12 PM
QuestysRecordID
3355446
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
295
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page 6 of 8 <br /> 7. UNDER-DISPENSER CONTAINMENT C TESTING <br /> Test Method Developed By: U UDC Manufacturer N Industry Standard U Professional Engineer <br /> U Other(Specify) <br /> Test Method Used: U Pressure U Vacuum IINHydrostatic <br /> U Other(Specify) <br /> Test Equipment Used: Caldwell Equipment Resolution: <br /> UDC# 1 &2 UDC# 3&4 UDC# 5&6 UDC# 7&8 <br /> UDC Manufacturer: Bravo Bravo Bravo Bravo <br /> UDC Material: Steel Steel Steel Steel <br /> UDC Depth: 9" 9" 911 911 <br /> Height from UDC Bottom to Top <br /> of Highest Piping Penetration: Bottom Bottom Bottom Bottom <br /> Height from UDC Bottom to <br /> Lowest Electrical Penetration: Bottom Bottom Bottom Bottom <br /> Condition of UDC prior to <br /> testing: Oily Oily Oily Oily <br /> Portion of UDC Tested 41V 411 All " <br /> Does turbine shut down when U Yes U No IXNA <br /> UDC sensor detects either UYes UNo ISI NA UYes UNo DENA UYes UNo NNA <br /> product or water?* <br /> Turbine shutdown response time N/A N/A N/A <br /> Is system programmed for fail- U Yes U No IXNA U Yes UNo NNA U Yes "UNo UNA U Yes UNo UNA <br /> safe shutdown?' <br /> Was fail-safe verified to be UYes UNo 1XNA uYes L1No xINA UYes UNo MYNA Li Yes UNo KNA <br /> operational? <br /> Wait time between applying <br /> pressure/vacuum/water and '2 hr. z hr. z hr. z hr. <br /> startingtest a <br /> Test Start Time: 1 1 . 2 5 9 00 11 :30 9 : 2 0 <br /> Initial Reading(R,): 0 0 0 0 <br /> Test End Time: 11 : 55 9:30 12 : 00 9 : 50 <br /> Final Reading(Rr): 0 0 0 0 <br /> Test Duration: ' <br /> Change in Reading R, R,): 0 0 0 0 <br /> Pass/Fail Threshold or-Criteria: Loss 0 Loss <br /> Test Result: LX Pass U Fall XI Pass U Fall N Pass U Fail HI Pass U FaB <br /> Was sensor removed for testing? U Yhs 0 No 1XNA U Yes U No HI NA U Yes UNo NNA U Yes UNo NNA <br /> Was sensor properly replaced and p Yes 0 No 1XNA U Yes U No BI NA U Yes UNo NNA U Yes UNo NNA <br /> verified functional after testing? <br /> Comments— (include information on repairs made prior to testin&and recommended jollowaip forfailed tests) <br /> ' If the testing method does not test the entire depth of the UDC,specify how much of the UDC was tested. Methods not testing the <br /> entire UDC should only be used if the monitoring system provides fail-safe turbine shutdown. (See SWRCB LG-160) <br /> 2 With the submersible pump running,place the sensor in product(discriminating sensors should also be placed in water). The time <br /> between placing the sensor in product and the turbine shutting down is the response time. This should be done if the secondary <br /> containment testing method used does not test the entire volume of the UDC <br /> This information is not needed if the entire UDC is tested. <br />
The URL can be used to link to this page
Your browser does not support the video tag.