My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2002-2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
COMPLIANCE INFO 2002-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2021 3:50:10 PM
Creation date
11/5/2018 9:14:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2006
RECORD_ID
PR0518288
PE
2361
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
3250 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
WNg
Supplemental fields
FilePath
\MIGRATIONS\G\GRANT LINE\3250\PR0518288\COMPLIANCE INFO 2002-2006.PDF
QuestysFileName
COMPLIANCE INFO 2002-2006
QuestysRecordDate
7/5/2017 7:22:22 PM
QuestysRecordID
3481896
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
238
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
v <br /> Alltech <br /> 17759 Buttercup Circle, Sonora, CA 95370 <br /> Phone: 209-532-7320; Fax: 209-533-2650 <br /> California Contractor 623541 A-Haz <br /> Mike@MtechPetro.com Fj% <br /> MONITORING SYSTEM CERTIFICATION <br /> A. General Information <br /> Facility Name: Costco# 658 Tracy Date of Testing/Servicing: September 1, 2004 <br /> Facility Address:3250 W. Grant Line Rd., Tracy CA 95304 <br /> Facility Contact Person: Leo Facility Phone: 209-834-1247 <br /> LIA: San Joaquin Health; Inspector: Steven Shih; LIA Phone: (209) 468-9850; LIA Fax: (209) 468-3433 <br /> Make/Model of Monitoring System: Veeder-Root TLS-350 <br /> B. Inventory of Equipment Tested/Certified: <br /> Tank ID:Regular 1 Tank Tank ID: Regular 2 Tank <br /> ®In-Tank Gauging Probe. Model:Mag 1 0 in-Tank Gauging Probe. Model:Mag 1 <br /> •Annular Space or Vault Sensor. Model:Single-Float Brine 0 Annular Space or Vault Sensor. Model:Single-Float Brine <br /> ®Piping Sump Sensor(s). Model:Discriminating Sensor ®Piping Sump Sensor(s). Model:Discriminating Sensor <br /> ®Fill Sump Sensor(s). Model:Discriminating Sensor JZ Fill Sump Sensor(s). Model:Discriminating Sensor <br /> ®Mechanical Line Leak Detector. Model:Vaproless ®Mechanical Line Leak Detector. Model:Vaporless <br /> ❑Electronic Line Leak Detector_ Model: ❑Electronic Line Leak Detector. Model: <br /> 0 Tank Overfill/High-Level Sensor. Model: ®Tank Overfill/High-Level Sensor. Model:Veeder-Boot Audible <br /> ❑Fillspill Bucket Tested: ®Pass []Fail E Fillspill Bucket Tested: ®Pass ❑Fail <br /> Other Fireextin guiskiers checked and to ed Other Fire a ishesr checked and to ed <br /> Tank ID:Premium Tank; Capacity: Tank ID:None <br /> ®In-Tank Gauging Probe. Model Mag 1 ❑In-Tank Gauging Probe. Model: <br /> •Annular Space or Vault Sensor. Model:Single-Float Brine ❑Annular Space or Vault Sensor. Model: <br /> •Piping Sump Sensor(s). Model:Discriminating Sensor ❑Piping Sump Sensor(s). Model: <br /> ®Fill Sump Sensor(s). Model:Discriminating Sensor ❑Fill Sump Sensor(s). Model: <br /> •Mechanical Line Leak Detector. Model:Vaporless ❑Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model:Veeder-Boot Audible ❑Tank Overfill/High-Level Sensor. Model: <br /> ®Fillspill Bucket Teste&: ®Pass ❑Fail ❑ 1'illspill Bucket Tested: ❑Pass []]Fail <br /> ®Other Fire extinguishers checked and tagged ❑Other Fire etititi uisher,checked and ed <br /> Dispenser ID: 1&2 0 Sump:®Dry❑Water❑Product Dispenser ID:3&4®Sump: ®Dry❑Water❑Product <br /> •Dispenser Containment Sensor(s). Model:Non-Discriminating ®Dispenser Containment Sensor(s). Model:Non-Discriminating <br /> ®Shear Valve(s) (Functional test) ®Shear Valve(s) (Functional test) <br /> •Fire ektnguisher checked and tagged ®Fire extin uisher checked and to ed <br /> Dispenser 1D: 5&6 l�j Sump:®Dry[]Water❑Product Dispenser ID: 7&8 M Sump: ❑Dry❑Water[]Product <br /> ®Dispenser Containment Sensor(s). Model:Non-Discriminating 0 Dispenser Containment Sensor(s). Model:Non-Discriminating <br /> ®Shear Valve(s) (Functional test) ®Shear Valve(s) (Functional test) <br /> ®Fire extinguisher checked and tagged ®Fire extinguisher checked and tagged <br /> Dispenser ID: 9&10®Sump: ®Dry❑Water❑Product Dispenser ID: 11&12® Sump: ®Dry❑Water❑Product <br /> ®Dispenser Containment Sensor(s). Model:Non-Discriminating ®Dispenser Containment Sensor(s). Model:Non-Discriminating <br /> ®Shear Valve(s) (Functional test) Shear Valve(s) (Functional test) <br /> 0 Fire extinguisher checked and tagged Fire extin uisher checked and tagged <br /> Dispenser ID: 13&14®Sump: ®Dry❑Water❑Product Dispenser ID: 15& 16❑Sump: ®Dry❑Water❑Product <br /> ®Dispenser Containment Sensor(s). Model:Non-Discriminating ®Dispenser Containment Sensor(s). Model:Non-Discriminating <br /> ®Shear Valve(s) (Functional test) ®Shear Valve(s) (Functional test) <br /> ❑Fire extinguisher checked and aed ❑Fire extin 'sher checked and tagged <br /> C. Certification-l certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guldetines. Attached <br /> to this Certification is a Piot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,l hatic also attached <br /> a copy of the report; ®System set-up N Alarm history repos! <br /> Technician: Mike Dotten,California Contractor 623541 A-Haz <br /> Certification:Veeder-Root: 006-05-0789;Level 4. <br />
The URL can be used to link to this page
Your browser does not support the video tag.