My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2002-2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
COMPLIANCE INFO 2002-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2021 3:50:10 PM
Creation date
11/5/2018 9:14:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2006
RECORD_ID
PR0518288
PE
2361
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
3250 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
WNg
Supplemental fields
FilePath
\MIGRATIONS\G\GRANT LINE\3250\PR0518288\COMPLIANCE INFO 2002-2006.PDF
QuestysFileName
COMPLIANCE INFO 2002-2006
QuestysRecordDate
7/5/2017 7:22:22 PM
QuestysRecordID
3481896
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
238
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page ca of a <br /> SWRCB,January 2002 4 <br /> 4. TANK ANNULAR TESTING <br /> Test Method Developed By: 0 try Standard 0 Professional Engineer <br /> 0 Other(Spec) <br /> Test Method Used: 0 Pressure X Vacuum ❑Hydrostatic <br /> 0 Other(Spec6) <br /> Test Equipment Used See attached testing procedures Equipment Resolution: <br /> Tank# a�jTl Tank ft f� j2 Tank# � -Tank# <br /> Is Tank Exempt From Testing?' , Yes 0 No F�Yes 0 No JaYes ❑No ❑Yes ❑No <br /> Tank Capacity: O- UGU to <br /> Tank Material: 1P r <br /> Tank Manufacturer: 6 r <br /> Product Stored: 4:- <br /> Wait <br /> Wait time between applying <br /> pressure/vacuum/water and 30 minutes 30 minutes 30 minutes 30 minutes <br /> starting test: <br /> Test Start Time: <br /> Initial Reading(R,): <br /> Test End Time: <br /> Final Reading(RF): <br /> Test Duration: <br /> Change in Reading(RF-N: <br /> Pass/Fail Threshold or Criteria: 0.00 0.00 0.00 0.00 <br /> Test Result: 0 Pass 0 Fail 0 Pass 0 Fail 0 Pass 0 Fail 0 Pass 0 Fail <br /> Was sensor removed for testing? 0 Yes 0 No DNA 0 Yes 0 No DNA 0 Yes 0 No 0 NA 0 Yes 0 No DNA <br /> Was sensor properly replaced and 0 Yes 0 No 0 NA 0 Yes 0 No DNA 0 Yes 0 No [INA 0 Yes 0 No DNA <br /> verified functional after testin 7 <br /> Comments—(include information on repairs made prior to testing and reeornmendedfollow-up for failed tests) <br /> SB 989 3-Year Compliance Testing <br /> WO#060310.045 — <br /> COSTCO#200737 — <br /> 3250 W Grant Line/Hwy 205 — <br /> Tracy,CA 95304 <br /> Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containment,such as systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment <br /> testing. {California Code of Reeulations.Title 23. Section 2637(a)(6)) <br />
The URL can be used to link to this page
Your browser does not support the video tag.