My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2002-2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
COMPLIANCE INFO 2002-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2021 3:50:10 PM
Creation date
11/5/2018 9:14:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2006
RECORD_ID
PR0518288
PE
2361
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
3250 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
WNg
Supplemental fields
FilePath
\MIGRATIONS\G\GRANT LINE\3250\PR0518288\COMPLIANCE INFO 2002-2006.PDF
QuestysFileName
COMPLIANCE INFO 2002-2006
QuestysRecordDate
7/5/2017 7:22:22 PM
QuestysRecordID
3481896
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
238
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page S of 3 <br /> SWRCB,January 2002 <br /> 5. SECONDARY PIPE TESTING <br /> Test Method Developed By: ❑Piping Manufacturer X Industry Standard ❑Professional Engineer <br /> ❑Other(Specify) <br /> Test Method Used: X Pressure ❑Vacuum . ❑Hydrostatic <br /> 0 Other(Specify) <br /> Test Equipment Used: See attached testing procedures Equipment Resolution 3 <br /> piping Run# rJ Piping Piping Run GY?Ia Piping Run <br /> Piping Material: <br /> Piping Manufacturer: VIA9 OA/ *' M S/`Z/nr <br /> Piping Diameter: <br /> Length of Piping Run: T— <br /> Product Stored: ( /��3L/••� �/ - ✓-- <br /> Method and location of <br /> piping-run isolation: <br /> Wait time between applying 30 minutes 30 minutes 30 minutes 30 minutes <br /> pressure/vacuum/water and <br /> starting test <br /> Test Start Time: <br /> Initial Reading(R): S/ <br /> Test End Time: ` /S 2 U Iola? <br /> Final Reading(RF): S /S / Pf <br /> Test Duration: 1 hour 1 hour 1 hour 1 hour <br /> Change in Reading(RF &): fid_ - -4&-- <br /> Pass/Fail Threshold or 0.00 0.00 0.00 0.00 <br /> Criteria: <br /> Test Result: I A Pass ❑Fail .?�Pass l7 Fail XPass ❑Fail ❑ Pass 0all <br /> Comments— (include information on r�Eirs made prior to testing and recommended follow-up for failed tests) <br /> IlAodg& 51-'C'o'u 'g ;;07cC21-, 5 CO AJOw9te Yy/,�� �'.r'�iAee7� FYr 22/-C <br /> SB 989 3-Year Compliance Testing <br /> WO#060310-045 <br /> COSTCO#200737 <br /> 3250 W Grant Line/Hwy 205 <br /> Tracy,CA 95304 <br />
The URL can be used to link to this page
Your browser does not support the video tag.