My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2002
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
INSTALL_2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/28/2023 1:00:14 PM
Creation date
11/5/2018 9:19:37 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2002
RECORD_ID
PR0518288
PE
2361
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
3250 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
WNg
Supplemental fields
FilePath
\MIGRATIONS\G\GRANT LINE\3250\PR0518288\INSTALL 2002.PDF
QuestysFileName
INSTALL 2002
QuestysRecordDate
7/5/2017 9:39:11 PM
QuestysRecordID
3482255
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
250
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
06/27/2002 12:58 FAX 425 251 8782 BARGHAUSEN Z007 <br /> California Edition:3anuary 2UO2 <br /> Marley Pump Co. <br /> Red Jacket FX1, FX2, FX1V, FX2V Flexline <br /> (for Flexible Pipelines) <br /> AUTOMATIC MECHANICAL LINE LEAK DETECTOR <br /> Certification: Leak rate of 3.0 gph with Pp= 100% and PFA=0%. <br /> Leak Threshold: 2.0 gph. A pipeline system should not be declared tight if the test result indicates a loss <br /> that equals or exceeds this threshold. <br /> Applicability; Gasoline, diesel, aviation fuel. <br /> Other liquids may be tested after consultation with the manufacturer. <br /> Specification: System tests pressurized flexible pipelines. <br /> Pipeline Capacity: Maximum of 49 gallons. <br /> Waiting Time: None between delivery and testing. <br /> None between dispensing and testing. <br /> Test Period: Response time is less than 3 minutes. <br /> System Features: Permanent installation on pipeline- <br /> Automatic testing of pipeline. <br /> Preset threshold. <br /> Single test to determine if pipeline is leaking. <br /> Restricted flow to dispenser if leak is declared. <br /> Calibration; Equipment must be checked annually for capability of detecting a line leak of 3.0 <br /> gph and, if necessary, calibrated in accordance with manufacturers instructions. <br /> Comments: Envirofiex pipeline with a bulk modulus'of 1,280 psi was used during this evaluation. <br /> To perform a valid test,time delays must be integrated into electronic dispensing <br /> equipment or retrofitted in junction box. Without this delay,there is no guarantee that a <br /> nozzle will be closed for sufficient time to allow leak detector to perform pipeline test and <br /> provide uninterrupted service. <br /> *See glossary. <br /> Marley Pump Co. Evaluator. Kien Wilcox Associates <br /> 500 East 59th St., P.Q. Box 3888 Tel: (816)443-2494 <br /> Davenport, IA 52807 Date of Evaluation: 03/22/94 <br /> Tel: (888)262-7539 <br /> 136 <br /> Appearance on this list is not to be conu"ed as an endorsement by any regulatory ardency nor Is It any guarantee of the performanca of <br /> the method or equipment_ Equipment should be installed and operated In accordance with all applicable laws and regulations. <br />
The URL can be used to link to this page
Your browser does not support the video tag.