Laserfiche WebLink
UST SYSTEM p/RRAVING INFORMATION <br /> I- V/ <br /> three complete sets of plans (include manufacturer's specification sheets for proposed IgLlipnent to be installed). <br /> 2- V Vans drawn to scale in non-erasable print. <br /> 3. Plot plan to show location of tanks and all associated piping- <br /> _ Striker plates or drop tube-mcxnted bottom protectors illustrated below all accessible openings- <br /> 5. lank cross-sectional diagram_ <br /> 6- Detail of tank, associated piping, excavation and cover. <br /> 7- lank(s) and piping approved by a nationally recognized independent testing organization. [Title 23, Chapter 16, <br /> Article 3, section 2631 (b) L 26351 <br /> g- ✓ Verification of product ccapatibitity with the tank(s), piping, monitoring <br /> device(s), epoxy or silicone glues, etc_ <br /> Manufacturer's written irtstallation instructions for tarak(s), piping, monitoring devices, etc. <br /> 10. ✓ At the installation site, prior to installation, a tightness test shall be performed on both primary (1`) snd <br /> secondary (2°) contairmrent systems before covering. [section 2635 (a) (3) L (G)] <br /> 11- IL lank integrity test required upon completion of installation with tame in operating condition. Test results to be <br /> submitted directly to PIIS-EMD from the testing company or owner of facility. [Health t Safety Code, Alvisfon 20, <br /> Chapter 6_7, Section 25291 (h)] <br /> 12. TANr COPF OSITIOM <br /> TANK f i 1 0 2 A 3 / s <br /> CAPACITY 20.000 20,000 2©,000 <br /> NA"ACTMU Containment Solutions <br /> C,OWOS111(w Fiberglass/Plastic <br /> P130EL DWT-6 TYPE II <br /> PRODUCT 87 octane $7 octane 92 octane <br /> CORROSION PROTECTION Fiber -s Reinforced Plastic <br /> U_l_ LISTED Yes Yes Yes <br /> COMPATiBILITY WITH 100% Yes Yes YES <br /> WIXAMX 1: <br /> 13_ TAfr(s) To ME INSTAL ED <br /> A. Steel-clad with ffberglass reinforced plastic coatings, ctwpusites, or equivalent roan-metallic exterior <br /> coatings or coverings. <br /> (1) Tested at the installation site using an electric resistance holiday detector. <br /> (2) Vacuum applied to interstitial space. <br /> 8. fiberglass <br /> (1) Installation instructinrss require an air test and soap btfe test prior to installation. <br /> (2l Vecuura applied to interstitial space. <br /> V (3) Hydrostatic annular (priafary tank pressure test)_ <br /> C. Icon-clad steel tank [Section 2635 (a) (2) (A)] <br /> (1) Cathodic protection provided for entire tank, piping and ccaporients (ruts, bolts, washers, <br /> etc_)_ <br /> (2) field installed cathodic protection systems desigried and certified as adequate by a <br /> corrosion specialist- <br /> _ Tw{rressed current systems to be impccttd no less than every 60 days- <br /> 5 <br />