Laserfiche WebLink
D. Alternate cons ;ion for new underground storage tanks contah motor vehicles fuel {section 26331- <br /> (1) Monitoring and response plan (Section 26343- <br /> (2) Underground storage tank composed of.... <br /> (a) Fiberglass reinforced plastic- <br /> (b) Cathodically protected steel. <br /> (c) Steel clad with fiberglass reinforced plastic- <br /> (d) other material that complies with section 2631 and 2632- <br /> ` (3) floor of leak interception and detection system constructed on a firm base and sloped to a <br /> collection sump (use of membrane liners comply with section 2631 (d) (6) requirements-) <br /> (4) Access casings installed in the collection sump of the secondary contairwrnent system with <br /> backfill in the interstitial space- The access casing shall meet all of the following: <br /> Designed and installed to allow the liquid to flow into the casing- <br /> _ Sized to allow removal of collected liquid and able to withstand all anticipated applied <br /> stresses. <br /> - Constructed of material that trill not be structurally weakened. <br /> - Screened along entire vertical zoite of permeable materiat. <br /> - Capable of preventing leakage of any hazardous substance from the casing. <br /> - Extend to the ground surface and covered with a locked waterproof cap. <br /> - Capable of meeting s_J_ Co_ PNS-END deli Standards. <br /> Leak interception and detection system shalt prevent the leaked hazardous substance from <br /> entering ground water. <br /> 14. INTERSTITIAL SPACE MONITORING <br /> A. V`sual monitoring [Section 2632 (c) (1)1 <br /> (a) Exterior surface and floor beneath tank monitored by direct viewing <br /> - (b) Daily visual inspections <br /> (c) Liquid level in tank to be recorded at time of inspection <br /> - (d) If liquid observed around or beneath primary tank, owner will determine if an unauthorized release <br /> has occurred. <br /> ll_ Kechanical or electronic monitoring (Section 2632 (c) (2)1 <br /> Ca) Contfnuous monitoring system connected to an sudib(e and visual alarm system. <br /> Monitoring equipment to be installed <br /> Manufacturer: FEEDER ROOT <br /> — Mode[ l(uotrer: 794380-352 TANK C1MPS) 794380-301 (ANNULAR) <br /> Sensor Type: — Vapor % Liquid— goth_ 794380-208 (DISPENSERS) <br /> Sensor/Pane( specifications_—ATTACHED <br /> Location(s) for sensors: <br /> Tank-_Interstitial Piping: In tUrbine cusp <br /> Dispenser: In dispen-ner Sinop <br /> C- Monitoring and response plan submitted (Section 2632 (d) (1) L <br /> 15. Any special accessories, fittings, coat; lint e tank or <br /> . or linings not inherent within the initial design of the i <br /> dole wall UST. coatings.(Section 2631 (b)I <br /> A- Approved by a nationatty recognized indeperaientt testing organization_ <br /> B_ Demborzstration of integrity with the Prrsmaory and/or secondary containment- <br /> 6 <br /> ortsirment_6 <br />