Laserfiche WebLink
16- V Tanks subject to float. [Section 2635 (a) (7)I <br /> A- Anchored by de.adnan or stab.. <br /> ®- Anchors to be installed as specified by manufacturer. <br /> e- Installation details provided on plans. <br /> O. Calculations provided. <br /> 1T. <br /> SPILL AND OVERFILL PREVENTION <br /> ` underground storage tank equipped with spill container and an overfill prevention system- <br /> / <br /> container(s)/piping sutp(s) required, including tank fill and all openings)- <br /> (detail drawing of spill <br /> t A- Spill container (Section 2635 (b) (1)). <br /> If made of metal, exterior wall protected from galvanic corrasion- <br /> - Capacity. (miniauru of five gallons) 5 ZallOn8 <br /> Equipped with a drain valve which allows drainage of spill into primary container_ <br /> V/ ?4anufacturer. PHIL—TITS MODEL #PT—SC-3600—TSC-2-1—NV—TBP <br /> $- Overfill prevention system does not allow for manuat override and meets one of the f011owiflg requiretttents. <br /> (1) Alert tratufer operator at 902 full by restricting the flow into the tank or triagerirlg an audib[c <br /> and visual atarw (section 2635(b)(2)(A)] . <br /> Manufacturer:, VEEDER ROOT tel. 790091-001 <br /> (2) Restrict delivery flow to the tank 30 minutes before overfill when tattle is filled at no more than <br /> 95% capacity and activates an audible alarm at least five minutes before overfill (Section 2635 <br /> (b) (2) (6)l_ <br /> Manufacturer- Model- <br /> o (3) Provide positive shut off at no more than 95% capacity (Section 2635 (b) (2) (C)]. <br /> Manufacturer_ OPW M,(_ 233VM-4433 W/53 VML-0120 . <br /> (4) Provide positive shut-off of flow to the tank so that the fittings on top of the tank are not <br /> exposed to the Product overfilling (Section 2635 (b) (2) (D)]. <br /> Manufacturer- Model <br /> 1b. PIPING INFORMATION <br /> PIPING INFORKATION TANG 1 TANI& 2 TAmu 3 <br /> TANKS <br /> DISTAMX <br /> DISPERSER ftroTAN1C 110' 143' 155' <br /> o <br /> MANUFACTURER ENVIERON <br /> SYSTEM TYPE ]'RESSM <br /> CONSTRUCTION ` DOUBLE 'WALL <br /> MATERIAL . SLE (HDPE) <br /> LEAK DETECTION SYSTEM continuous turbine s sensor w audible S istial alarms <br /> 1002 METHANOL CCIMPATIOILiTT g YES Nl7 <br /> CORROSION PROTECTION g TES NO <br /> System Type; suction, pressure, and gravity <br /> Construction: single wailed, double-walled, lined-trench, etc. <br /> Material Type; steel with cathodic protection, stainless steel, fiberglass reinforced plastic. <br /> 7 <br />