Monitoring <br /> Hydrostatic Monitoring System helps <br /> guard against leaks and liabilities. <br /> Normal Conditions coNCRETETRAfFICPAD- Containment Solutions recommends the Hydrostatic <br /> The reservoir liquid -,�. -.E o, Monitoring System for double-wall tanks because of its <br /> level will be stable if OPTTNAL RESERVOIR superior leak detection capability. By filling the cavity <br /> both the inner and LICUM LEVEL SENSOR <br /> between the inner and outer tank walls with a non- <br /> STABLE RfSFAVOIR <br /> outer tanks are tight. Llau6OLEVEL hazardous liquid, hydrostatic pressure is continuously <br /> The reservoir sensor k= applied to both the primary and secondary tank. This <br /> will activate an alarm STORED system is capable of detecting tank leaks in either the <br /> if the reservoir drains PRooucr primary or secondary tank walls for all installed <br /> or overfills. DauBCE-WALL. conditions, <br /> r a c UND1. <br /> The Hydrostatic Monitoring System, with a stand pipe, <br /> can also serve the dual function of a precision tank test. <br /> Inner Wall Breach The system has been independently tested and <br /> Monitor fluid drainsfl <br /> statistically validated to meet the EPA and National Fire <br /> into the primary tank Protection Association's criteria as a precision tank test. <br /> causing the reservoir Using a stand pipe, the system has been shown to be <br /> liquid level to drop '. <br /> x capable of detecting leaks as small as 0.10 gallons per <br /> and activate alarm. ` hour with a 99.9% probability of detection and less than <br /> No petroleum product BREACH'u a 12% probability of a false alarm, <br /> v o <br /> escapes from the pri- <br /> mary tank to conta- ,f t n All the fiberglass double-wall tanks in this brochure can <br /> curinate the annular include the optional fiberglass reservoir necessary for <br /> space. the Hydrostatic Monitoring System. <br /> ' <br /> The Hydrostatic Monitoring System provides <br /> Outer Wall Breach <br /> Groundwater <br /> continuous leak detection while avoiding false alarms <br /> Below Tank Top caused by changes in product temperature, product <br /> If the groundwater is level, tank deflection under loads, or groundwater <br /> below the tank top,the conditions. <br /> monitor fluid drains -Accessories <br /> into the ground, caus- <br /> ing the reservoir liquid Antifreeze Mixtures <br /> level to drop and In areas where ambient temperatures or delivered <br /> activate the alarm. '` °W products may be subjected to freezing conditions, an <br /> antifreeze solution must be used with our Hydrostatic <br /> Outer Wall Breach <br /> Tank Monitor to avoid potential tank damage. <br /> �-�� ��� _ <br /> Groundwater Brine Antifreeze Solution <br /> Over Tank Top GROUNDWATER Our pre-mixed and blended calcium chloride solution <br /> VCI <br /> If the groundwater is �— OV B ILS provides freeze protection to -40°F.This non-toxic brine <br /> OVERFILLS p <br /> over the tank top, the antifreeze can be factory-installed into tanks measuring <br /> reservoir will fill up up to 10' diameter and 30,000-gallon capacity. Its color <br /> with groundwater and tracer helps detect hidden damage from shipping or <br /> activate the high level <br /> OUTER TANK jobsite handling. <br /> alarm on the reservoir �--~BREACH <br /> sensor. - --- <br /> �o <br />