My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0000150
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
ASHLEY
>
7644
>
3500 - Local Oversight Program
>
PR0543394
>
ARCHIVED REPORTS XR0000150
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/5/2018 3:57:17 PM
Creation date
11/5/2018 10:23:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0000150
RECORD_ID
PR0543394
PE
3528
FACILITY_ID
FA0003967
FACILITY_NAME
AT&T California - UE132
STREET_NUMBER
7644
Direction
N
STREET_NAME
ASHLEY
STREET_TYPE
Ln
City
Stockton
Zip
95212
CURRENT_STATUS
02
SITE_LOCATION
7644 N Ashley Ln
P_LOCATION
99
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
o ICRP Systems <br /> 4 <br /> The inductively coupled argon plasma systems are calibrated <br /> daily by an external standard calibration process. Specific <br /> methods may impose variations and/or different acceptance <br /> criteria upon this calibration. These specific requirements are <br /> found in the CHCMUCST SCP covering the particular method in <br /> question. <br /> o Daily Cxternal Standard Calibration Procedure: <br /> For each analyte, or group of analytes, to be analyzed, <br /> initial calibration standards are prepared by adding aliquots <br /> of one or more stock standards to volumetric flasks and <br /> diluting to volume with an appropriate solvent. These <br /> standards should be at concentrations that define the maximun <br /> range of the method. Continuing calibration standards, <br /> containing the sane analytets> as the calibration standards, <br /> are prepared in the same manner, but at approximately SOX of <br /> 1 the calibration standard concentrations . <br /> The appropriate initial calibration standard, followed by an <br /> appropriate blank solution, arc introduced into the xCnp <br /> system in duplicate using the technique used for the <br /> introduction of actual aamples . The ICRF system calculates a <br /> response factor based on the sytem response to both the <br /> standard and blank . This is followed by duplicate <br /> introductions of the appropriate continuing calibration <br /> standard . The continuing calibration standard is analyzed <br /> after every ten samples . <br /> o Results from the duplicates of each sample or standard <br /> must have a percent relative standard deuiation (XRSO) <br /> less than or equal to 20X. <br /> o If this criteria is not net, the sample Or <br /> standard analysis must be repeated . <br /> o Results from the continuing calibration standards must <br /> fall within f/- 13X of the expected value . <br /> o If this criteria is not net, the standard <br /> analysis must be repeated . <br /> o If the standard still does not meet the criteria, <br /> the entire standardization procedure is repeated . <br />�i <br /> 21 <br />
The URL can be used to link to this page
Your browser does not support the video tag.