My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0000150
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
ASHLEY
>
7644
>
3500 - Local Oversight Program
>
PR0543394
>
ARCHIVED REPORTS XR0000150
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/5/2018 3:57:17 PM
Creation date
11/5/2018 10:23:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0000150
RECORD_ID
PR0543394
PE
3528
FACILITY_ID
FA0003967
FACILITY_NAME
AT&T California - UE132
STREET_NUMBER
7644
Direction
N
STREET_NAME
ASHLEY
STREET_TYPE
Ln
City
Stockton
Zip
95212
CURRENT_STATUS
02
SITE_LOCATION
7644 N Ashley Ln
P_LOCATION
99
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br /> o An Systems <br /> 1 The atonic absorption systems are calibrated daily by an <br /> i <br /> external standard calibration process . Specific nethods may <br /> t impose variations and/or different acceptance criteria upon this <br /> calibration. These specific requirements are found in the <br /> CNrMUCST SRP covering the particular method in question . <br /> 1 o Daily External Standard Calibration Procedure: <br /> ror each anaivte. or group of analytes, to be analyzed, <br /> Initial calibration standards„ at three to four different <br /> concentrations, are prepared by adding aliquots of one or more <br /> stock standards to uolunetric flasks and diluting to volume <br />» with an appropriate solvent. One of the standards should be <br /> at concentrations near the detection limits of the method . <br /> Continuing calibration standards, containing the same <br /> analyte(s) as the calibration standards, are prepared in the <br /> same manner, but at approximately the mid-point of the <br /> w calibration standard concentration ranges . <br /> Each of the appropriate Initial calibration standards, <br /> followed by an appropriate blank solution, are introduced into <br /> the !1A system in replicate using the technique used for the <br /> introduction of actual samples. The nn system calculates a <br /> set of response factors based on the syten response to both <br /> the standards and blank, and displays the results as a <br /> calibration curve . This is followed by replicate introductions <br /> of the appropriate continuing calibration standard . The <br /> continuing calibration standard is analyzed after every ten <br /> samples . <br /> r <br /> o Acceptability of system generated calibration curves <br /> is made by visual inspection of the curves . <br /> o If the curves are judged unacceptable, the <br /> calibration standards are reanalyzed . <br /> 1 <br /> o Results from the replicates of each sample or standard <br /> must have a percent relative standard deviation (XRS0) <br /> less than or equal to 2OX. <br /> o If this criteria is not net, the sample or <br /> 1 standard analysis i+ust be repeated . <br /> o Results from the continuing calibration standards must <br /> fall within F/- 13% of the expected value . <br /> o It this criteria is not net, the standard <br /> 1� analysis must be repeated . <br /> o If the standard still does not meet the criteria, <br /> the entire standardization procedure is repeated . <br /> 22 <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.