My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FRONTAGE
>
1002
>
2300 - Underground Storage Tank Program
>
PR0231604
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/10/2022 3:22:51 PM
Creation date
11/5/2018 10:30:18 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231604
PE
2361
FACILITY_ID
FA0000650
FACILITY_NAME
GAS & SHOP
STREET_NUMBER
1002
STREET_NAME
FRONTAGE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
26102012
CURRENT_STATUS
01
SITE_LOCATION
1002 FRONTAGE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\F\FRONTAGE\1022\PR0231604\BILLING 2010-2015.PDF
QuestysFileName
BILLING 2010-2015
QuestysRecordDate
11/30/2017 8:57:54 PM
QuestysRecordID
3740259
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
139
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA <br /> STATE WATER RESOURCES CONTROL BOARD iy <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM R <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> MARK ONLY 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑ 8 TANK REMOVED 1 <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: 7I MO1D Tl.-c}C K PC-P12-P�, <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-- SPECIFY IF UNKNOWN <br /> A. OWNER'S TANK 1.0.# B. MANUFACTURED BY: M008—f-1,/ W61_DIILI <br /> C. DATE INSTALLED(MODAYNEAR) A-Pgp I �CJ D. TANK CAPACITY IN GALLONS Om <br /> II.TANK CONTENTS IF A-1 IS MARKED,COMPLETE ITEM C. <br /> A� ,K 1 MOTOR VEHICLE FUEL ❑ 4 OIL B. C ❑ 18 REGULAR UNLEADED ❑ 3 DIESEL ❑ 6 AVIATION GAS <br /> El1b PREMIUM UNLEADED ❑ 4 GASAHOL 7 METHANOL <br /> 2 PETROLEUM F7 80 EMPTY �"1 PRODUCT E:1 1c MIDGRADE UNLEADED � 5 JET FUEL ❑ 8 M85 <br /> ❑ 3 CHEMICAL PRODUCT El 95 UNKNOWN 1--] 2 WASTE ❑ 2 LEADED 99 OTHER(DESCRIBE IN ITEM D.BELOW) <br /> 0. IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C A S 0: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY iN BOXES A.B,AND C,AND ALL THAT APPLIES IN BOX D AND E <br /> A TYPE OF 1 DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER ❑ 5 INTERNAL BLADDER SYSTEM E 95 UNKNOWN <br /> SYSTEM ❑ 2 SINGLE WALL ❑ 4 SINGLE WALL IN A VAULT ❑ 99 OTHER <br /> B. TANK ❑ 1 BARE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS �4 STEEL CLAD WI FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ 8 14C% METHANOL COMPATIBLE W/FRP <br /> (Primary Tank) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> C.INTERIOR ❑ 1 RUBBER LINED ❑ 2 ALKYD LINING ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> LINING OR F-15 GLASS LINING � 6 UNLINED 0 95 tlfIKNOWN ❑ 99 OTHER <br /> COATING IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? YES_ Np_ <br /> D.EXTERIOR ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 VINYL WRAP 4 FIBERGLASS REINFORCED PLASTIC <br /> CORROSION <br /> CORKPROTCYTON ❑ 5 CATHODIC PROTECTION ❑ 91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> E.SPILL AND OVERFILL,etc. SPILL CONTAINMENT STALLED(YEAR) OVERFILL EVENTION EQUIPMENT INSTALLED(YEAR) <br /> DROP TUBE YES NO STRIKER PLATE YES NO DISPENSER CONTAINMENT YES NO <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A&2 PRESSURE A U 3 GRAVITY A U 4 FLEXIBLE PIPING A U 99 OTHER <br /> B, CONSTRUCTION A U 1 SINGLE WALL AG 2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)AU04 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL WI COATING A U B 100% METHANOL COMPATIBLE WiFRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A U 95 UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION 1 MECHANICAL ONE LEAK E 2 LINE TIGHTNESS 3 CONTINUOUS INTERSTITIAL 4 ELECTRONIC LINE M 5 AUTOMATIC PUMP <br /> DETECTOR TESTING MONITORING LEAK DETECTOR SHUTDOWN ❑ 99 OTHER <br /> V.TANK LEAK DETECTION <br /> ��❑,/��(/1 <br /> VISUAL CHECK 2 MANUAL ANNUAL <br /> RECONCIL ATION INVENORY3 MONITORING VADOZE4 GA GING IC TANK El5 MROON7 TORINGTER ❑ 6 TESTINGTANK <br /> 7 CONTINUOUS MONITORING INTERSTITIAL ❑ 8 SIR O 9 WEEKLY MANUAL ❑ 10 TMONTHLY TANK O 95 UNKNOWN ❑ 99 OTHER <br /> TANING <br /> V1.TANK CLOSURE INFORMATION(PERMANENT CLOSURE IN-PLACE) <br /> I.ESTIMATED DATE LAST USED(MO/DAYNR) J 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> "' <br /> SUBSTANCE REMAINING GALLONS INERT MATERIAL? Y <br /> THIS FORM HAS BEEN COMPLETED UNDER ALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br /> TANK OWNER'S NAME DATE <br /> (PRINTED a SIGNATURE�M I�� L os- ( �L� <br /> r, rl <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY* JURISDICTION# FACILITY It TANK# p <br /> STATE I.D.# <br /> PERMIT NUMBER PERMIT APPROVED BY(DATE PERMIT EXPIRATION DATE <br /> I <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION-FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. FORM C MUST BE COMPLETED FOR INSTALLATIONS. THIS FORM <br /> SHOULD BE ACCOMPANIED BY A PLOT PLAN. FILE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THE UNDERGROUND STORAGE TANK REGULATIONS <br /> FORM B (6-95) <br />
The URL can be used to link to this page
Your browser does not support the video tag.