My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FRONTAGE
>
1002
>
2300 - Underground Storage Tank Program
>
PR0231604
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/10/2022 3:22:51 PM
Creation date
11/5/2018 10:30:18 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231604
PE
2361
FACILITY_ID
FA0000650
FACILITY_NAME
GAS & SHOP
STREET_NUMBER
1002
STREET_NAME
FRONTAGE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
26102012
CURRENT_STATUS
01
SITE_LOCATION
1002 FRONTAGE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\F\FRONTAGE\1022\PR0231604\BILLING 2010-2015.PDF
QuestysFileName
BILLING 2010-2015
QuestysRecordDate
11/30/2017 8:57:54 PM
QuestysRecordID
3740259
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
139
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�/ � oUnCG4 <br /> STATE OF CALIFORNIA �. <br /> STATE WATER RESOURCES CONTROL BOARD sy b o <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM, <br /> MARK ONLY I NEW PERMIT 3 RENEWAL PERMIT �❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ONE ITEM ❑ 2 INTERIM PERMIT O 4 AMENDED PERMIT 6 TEMPORARY TANK CLOSURE 8 TANK REMOVED f <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: -3-I MGp TSL-L1c K— P(_.AZLt 1 <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-- SPECIFY IF UNKNOWN <br /> A OWNER'S TANK I.D.$ B. MANUFACTURED BY; /YI D069—) tA✓EZUI A)G� <br /> C. DATE INSTALLED(MO/DAYNEAR) (( r�� D. TANK CAPACITY IN GALLONS: I ZA DOC) <br /> II.TANK CONTENTS IF A-1 IS MARKED,COMPLETE TEM C. <br /> A �1 MOTOR VEHICLE FUEL ❑ 4 OIL B. C. <br /> Ta REGULAR UNLEADED ❑ 3 DIESEL L_] 6 AVIATIONGAS <br /> O 1b PREMIUM UNLEADED ❑ 4 GASAHOL ❑ 7 METHANOL <br /> ❑ 2 PETROLEUM ❑ 80 EMPTY �1 PRODUCT ❑ 1c MIDGRADE UNLEADED 5 JET FUEL❑ ❑ <br /> 8 M65 <br /> ❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 2 LEADED ❑ 99 OTHER(DESCRIBE IN ITEM D.BELOW( <br /> D, IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C.A.S.# <br /> Ill. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A,B.AND C.AND ALL THAT APPLIES IN BOX D AND F <br /> A, TYPE OF 1 DOUBLE WALL 3 SINGLE WALL WITH EXTERIOR LINER ❑ 5 INTERNAL BLADDER SYSTEM E_] 95 UNKNOWN <br /> SYSTEM ❑ 2 SINGLE WALL ❑ 4 SINGLE WALL IN A VAULT ❑ 99 OTHER <br /> B. TANK ❑ 1 BARE STEEL 2 STAINLESS STEEL a 3 FIBERGLASS 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ 8 100% METHANOL COMPATIBLE W1FRP <br /> (Primary Tank) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> C.INTERIOR ❑ 1 RUBBER LINED 2 ALKYD LINING ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> LINING OR ❑ 5 GLASS LINING 6 UNLINED ❑ 95 UyiKNOWN ❑ 99 OTHER <br /> COATING IS LINING MATERIAL COMPATIBLE WITH 100'/a METHANOL? YES_ NO_ <br /> D.EXTERIOR ❑ 1 POLYETHYLENE WRAP F-1 2 COATING ❑ 3 VINYL WRAP 4 FIBERGLASS REINFORCED PLASTIC <br /> CORROSION <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> E.$PILL AND SPILL CONTAINMENT I FI <br /> TALLED(YEAR) OVERFILL EVENTION EQUIPMENT INSTALLED(YEAR) <br /> DROP TUBE YES NO STRIKER PLATE YES NO DISPE <br /> OVERFILL,etc. NSER CONTAINMENT YES NO <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION U 2 PRESSURE A U 3 GRAVITY A U 4 FLEXIBLE PIPING A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALL A 2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A 04 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL W/COATING A U 8 100% METHANOL COMPATIBLE WIFRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A U 95 UNKNOWN A U 99 OTHER <br /> 1 MECHANICAL LINE LEAK 2 UNE TIGHTNESS 3 CONTINUOUS INTERSTITIAL 4 ELECTRONIC LINE71 5 AUTOMATIC PUMP 99 OTHER <br /> D. LEAK DETECTION pETECTOR TESTING MONITORING ❑ LEAK DETECTOR SHUTDOWN ❑ <br /> V.TANK LEAK DETECTION <br /> 1 VISUAL CHECK ❑ 2 RMANUAL ECONCILIATION <br /> '❑ 3 VADMON`IITORING 4 AUTGAUOGINGIC TANK ❑ 5 MOOrONTNORINGTER ❑ 6 TESTINGTANK <br /> 7 MONITORING INTERSTITIAL F-18 SIR E7:] 9 WEEK LY MANUAL ❑ 10 MO TINGY TANK F-] 95 UNKNOWN Ll 99 OTHER <br /> VI.TANK CLOSURE INFORMATION(PERMANENT CLOSURE IN-PLACE) <br /> 1.ESTIMATED DATE LAST USED(MO/OAY/YR) � 2.ESTIMATED OUANT1 Y OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING GALLONS INERT MATERIAL? <br /> THIS FORMS HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br /> TANK OWNER'S NAME DATEib <br /> (PRINTED S SIGNATURE) M5! Ci/�i �, I <br /> LOCAL AGENCY USE ONLY THE ST .NUMBER I OMPOSED OF THE FOUR NUMBERS BELOW Y <br /> COUNTY# JURISDICTION# FACILITY# TANK# OCi% <br /> STATE LCI.# m u 17 8 9 '7 <br /> PERMIT NUMBER PERMIT APPROVED BYtOATE PERMIT EXPIRATION DATE <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION-FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. FORM C MUST BE COMPLETED FOR INSTALLATIONS. THIS FORM <br /> SHOULD BE ACCOMPANLED BY A PLOT PLAN. FILE THIIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THE UNDERGROUND STORAGE TANK REGULATIONS <br /> FORM B (6-95) <br />
The URL can be used to link to this page
Your browser does not support the video tag.