Laserfiche WebLink
SWRCB,January 2002 <br /> • • Page of <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: O Sump Manufacturer X Industry Standard D Professional Engineer <br /> D Other(Spec) <br /> Test Method Used: D Pressure D Vacuum X Hydrostatic <br /> D Other(Specify) <br /> Test Equipment Used: See attached testing results Equipment Resolution <br /> s. �y � l'keav, _;� .4r+^y. ' .a...:e-�xi�_ •o-.ux:.,._ :....-��_wx�a� ._. -:?..s-.s s _ .,..ems ._'_.; .. _ ;�r.,..y <br /> t h � <br /> Sump# cl7r Sump# X97Sum # 9( Sump# <br /> Sump Diameter: <br /> Sump Depth: Jr 5 S� Jr <br /> Sump Material&Manufacturer. r ,i6l9sS TG �� ,tom, <br /> Height from Tank Top to Top of <br /> Highest iping Penetration: G <br /> Height from Tank Top to Lowest J j 4 Z 3 /571, <br /> /51, <br /> Electrical Penetration: <br /> Condition of sump prior to testing: 41F4041P L <br /> Portion Of$lnn Tested' Above highest Above highest Above highest Above highest <br /> Sump nebetion penetration peneftittion enetration <br /> Does turbine shut down when <br /> sump sensor detects liquid(both D Yes D No X NA O Yes O No X NA D Yes D No X NA D Yes O No X NA <br /> induct and water)? <br /> Turbine shutdown response time <br /> Is system programmed for fail-safe O Yes O No X NA O Yes O No X NA O Yes O No X NA O Yes O No X NA <br /> shutdown?, <br /> Was fail-safe verified to be O Yes D No X NA O Yes D No X NA Dyes ONO XNA O Yes ONO X NA <br /> operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and starting 30 minutes 30 minutes 30 minutes 30 minutes <br /> test: z Q <br /> Test Start Time: 12- 1. 11 3• :O I <br /> Initial Reading(Ri): b.Al jA5 3.9%) O t+3 <br /> Test End Time: 12.%. 29 3 '. 1 / 2 , <br /> Final Reading(RF): 6A446 <br /> Test Duration: / 'n' t^ ` <br /> Change in Reading(RF-R): 0.00010 D, voo 9 3 <br /> Pass/Fail Threshold or Criteria: 0.002 0.002 0.002 0.002 <br /> Test Result: jUass D Fail ass D Fail (Pass O Fail D Pass D Fail <br /> Was sensor removed for testing? X Yes D No DNA X_Yes D No DNA X Yes O No [INA X Yes D No DNA <br /> Was sensor properly replaced and X Yes D No DNA X Yes O No DNA X Yes O No DNA X Yes O No DNA <br /> verified functional after testing? — — — <br /> Comments— (include information on repairs made prior to testing and recommended follow-up for failed tests) <br /> SB 989 6 mo. test <br /> WO#: 040920-117 <br /> Costco#38 <br /> 1616 E. Yammer Lane &West <br /> Stockton, CA 95210 <br /> If the entire depth of the sump is not tested,specify how much was tested. If the answer to M of the questions indicated with an <br /> asterisk(')is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />