My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1630
>
2300 - Underground Storage Tank Program
>
PR0518624
>
COMPLIANCE INFO_2016-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/11/2021 11:13:49 AM
Creation date
11/5/2018 11:20:23 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016-2018
RECORD_ID
PR0518624
PE
2371
FACILITY_ID
FA0024496
FACILITY_NAME
Costco Wholesale #38 (Gas Station)
STREET_NUMBER
1630
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95210
APN
09428011
CURRENT_STATUS
01
SITE_LOCATION
1630 E Hammer Ln
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\H\HAMMER\1630\PR0518624\COMPLIANCE INFO 2016-PRESENT .PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
202
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax: (209) 468-3433 Web:www.siaov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Costco Wholesale#38 1 1616 E Hammer Ln, Stockton March 02, 2017 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 316 HSC 25290.1(c3), 25290.2(c3) Secondary containment not constructed to prevent water intrusion (after Jul 2003). <br /> Brine and water were found in the fuel additive sump, and water was found in the 87-product(A)fill sump and <br /> 87-product(B)fill sumps. Secondary containment shall be constructed to prevent any water intrusion into the <br /> system by precipitation, infiltration, or surface runoff. The service technician removed approximately one-quarter <br /> cup of brine and one-quarter cup of water from the fuel additive sump, approximately one-quarter cup of water from <br /> the 87-product(B)fill sump and approximately one-eighth cup of water from the 87-product(A) sump and returned <br /> the sensors to their proper locations. Continue to monitor the fuel additive, 87-product A and B fill sumps and if the <br /> liquid returns, immediately contact a properly licensed, trained, and certified contractor to address the water <br /> intrusion. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the Environmental Health <br /> Department (EHD)with a statement documenting the corrective actions that have been or will be taken for each <br /> violation, and any supporting paperwork, by April 1, 2017. <br /> The 87 product(A tank), 87 product(B tank) and 91 product spill containers failed to contain a five-gallon <br /> capacity. When these three spill containers fail they shall be replaced with a spill container that has a minimum <br /> capacity of five gallons, is protected by galvanic corrosion, and has either a drain valve which allows drainage of <br /> the collected spill into the primary container or provides a means to keep the spill containers empty pursuant to <br /> CCR, Title 22, section 2635(b)(1). <br /> Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br /> Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br /> applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br /> Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br /> THIS FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: March 02, 2017 Inspector: Inspector Phone: <br /> Printed Name and Title: VICKI MCCARTNEY, Senior REHS (209)468-9852 <br /> Sayeed Mohammed, Gas Station Attendant <br /> FA0001705 PRO518624 SCO01 03/02/2017 <br /> EHD 23-01 Rev.09/22/16 Page 4 of 4 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.