My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3003
>
2300 - Underground Storage Tank Program
>
PR0503426
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/11/2021 5:13:18 PM
Creation date
11/5/2018 11:22:22 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0503426
PE
2381
FACILITY_ID
FA0004400
FACILITY_NAME
STOCKTON STEEL CO
STREET_NUMBER
3003
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95212
APN
12618002
CURRENT_STATUS
02
SITE_LOCATION
3003 E HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\H\HAMMER\3003\PR0503426\COMPLIANCE INFO.PDF
QuestysFileName
COMPLIANCE INFO
QuestysRecordDate
5/9/2013 8:00:00 AM
QuestysRecordID
163600
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
72
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Herrick SEP <br /> EN FIE Mt7�SERVIC STAL TH <br /> September 29, 1987 <br /> Dan Moe, R.S. <br /> ENVIRONMENTAL HEALTH DIVISION <br /> San Joaquin Local Health District ��//�� <br /> P.O. Box 2009 300-3 {~ . XlaWV77 i /1'1 <br /> Stockton, CA 95201 <br /> RE: UNDERGROUND FUEL STORAGE <br /> TANK TIGHTNESS TESTING <br /> Dear Dan, <br /> Attached please find test date and results performed by Integrity Tank Testing <br /> Systmes on our underground fuel storage tanks for 1987. <br /> Please note that initial test, 7/6/87, showed failure of the 10,000 gallon <br /> gasoline and 10,000 gallon diesel tanks. These tanks were uncovered and in- <br /> spected to determine the reason(s) for failure. It was determined that im- <br /> proper venting was creating air pockets which could not be relieved that <br /> accounted for the gains. The tanks were revented and 4 inch risers attached <br /> to center bungs. Tanks were then covered and re-testing performed on 9/21/87. <br /> Re-test results show tanks within tank tightness parameters. <br /> Regards, <br /> GGGtG►'i� <br /> G y Scheuring o,(��' <br /> Purchasing Agent <br /> Stockton Steel, Inc. <br /> GS:dc <br /> ATTACHMENTS <br /> STOCKTON <br /> STEEL <br /> The Herrick Corporation,PO.Box 8429,Stockton,California 95208(209)931-4751 DIVISION OF THE HERRICK CORPORATION <br />