WESTIC TECHNOLOGIES, INC. <br /> All excavated soils ( spoils ) shall be placed s minimum <br /> of two feet back from the edge of the excavation. <br /> The use of heavy and/or vibrating equipment (with the <br /> exception of the excavating equipment itself) adjacent <br /> to excavations shall be prohibited. <br /> All excavated areas shall be clearly marked and/or <br /> fenced to prevent unauthorized and/or accidental entry <br /> into work areas . <br /> Necessary foot and vehicle traffic shall be directed <br /> away from and around excavation work areas, and the <br /> routes clearly marked• <br /> Excavations shall be protected from intrusion of water. <br /> 8. 3. 6 CONFINED SPACE ENTRY <br /> The scope of work does not require personnel to enter into <br /> tanks, excavations , or other confined spaces. Field <br /> personnel are strictly forbidden to enter any confined <br /> spaces , for any reason, as a safety mandate of this SHP. <br /> Therefore, the SHP does not currently address confined space <br /> entry hazards and/or safety procedures. The SHP shall be <br /> revised , reviewed, and approved prior to any confined space <br /> entry work, should this operation become necessary. <br /> 8 . 3. 7 HOT WORK: <br /> Hot work may be defined as any operation which may <br /> potentially create a source of ignition. This operation is <br /> extremely dangerous when conducted anywhere that a flammable <br /> and/or explosive atmosphere (or fire hazard) may be present . <br /> because the tanks and pipelines to be removed and scrapped <br /> are expected to contain at least some residues ( if not <br /> measurable Quantities) of gasoline (i . e. , flammable or <br /> Combustible, depending on the substance) . sources of <br /> Ignition shall be eliminated during all operations that mey <br /> interact with tank atmosphere. <br /> For tank removal operations, all tanks shall be inerted <br /> using dry ice at 30 lbs. per 1. 000 gallons , tank <br /> atmospheres shall be checked using a properly calibrated <br /> combustible gas meter for percent oxygen (% Oz ) Prior to <br /> removal from the ground. AND prior to opening and scrapping. <br /> Representative samples Shall be taken from various <br /> locations/levels within each tank to ensure that the <br /> environment is consistant. Prior to lifting and cutting. <br /> atank atmospheres must be less than 10 percent LEL (<10% <br /> LEL) and less than 12 percent oxygen (<12% Oma ) . <br />