Laserfiche WebLink
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd/unitiii.htmi <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> Facility name: Designated Operator: Exp.date: Inspection <br /> Date: <br /> Facility add ss: UST# �. <br /> D rL �✓�- Product <br /> Titl <br /> Facility contact: e: Phone: <br /> Mori ring panel: �. Piping system: Overfill prevention: <br /> ♦a.— ressurized ❑Suction ❑Gravity echanicel ❑Audiblelvisual <br /> Inspection type: — 6,114 Violations: <br /> Routine G Monitoring Certification C Installation Other: jr` ❑M1-RDetect C M2-RPrev ❑M-3 Both <br /> On site Techniciank-�'s Name: ICC Service Technician Exp.Date: Manufactu er's Training: <br /> /` <br /> De'.P- oll - !© � y-4111 <br /> # Code Section VIOLATI N(S) HSC=Califomia Health&Safety Code;CCR=California Code of Regulations V R <br /> V=Violation;RV=Re eat Violation V <br /> 1 HSC 25284 No permit to operate <br /> 2 CCR 2637 Secondary containment: (a)test not performed;(e)test report not submitted within 30 days; (f)test notification not <br /> provided to the EHD at least 48 hours prior to conducting the test <br /> 3 CCR 2711(b)&(c) Current Unified Program Consolidated Forms not on file with the EHD(Facility and tank form) <br /> 4 HSC 25292.2 Current financial responsibility documents not on file with the EHD <br /> 5CCR 2632(b) Monitoring Program(Monitoring&Response Plan)is not current or approved by the local agency <br /> 6 CCR 2712(i) Monitoring and/or response plan is not onsite <br /> Maintenance&monitoring records not maintained 3 years,cathodic protection records for 6%years, (M1) <br /> written performance claims pertaining to release detection systems for 5 years,or records of repairs,linings,and <br /> 7 CCR 2712(b) upgrades for the life of the tank. Monitoring records include:(1)date and time of all monitoring or sampling; (2) <br /> monitoring equipment calibration and maintenance records;(3)results of any visual observations;(4)results of <br /> sample analysis performed a lab or in the field;(5)logs of all readings of gauges or other monitoring equipment, <br /> round water elevations,or other test results; 6 results of inventory readings and reconciliations. <br /> 8 CCR 2643(d) Daily monitoring of suction piping(pre-January 1, 1984)not performed 11 <br /> 9 HSC 25292.1 UST system is not operated to prevent unauthorized release,including spills and overfills <br /> 10 CCR 2632(c)(2) Monitoring system is not present in the interstitial space of a double walled UST/piping (Mt) <br /> 11 CCR 2630(d) UST monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity (M1) <br /> 12 HSC 25291(b) UST system monitoring equipment is not operational (Mt) <br /> 13 CCR 2636(f)(1) Failed to maintain a continuous monitoring system for underground piping&UDC that to activates an (M1) <br /> audible and visual alarm or stops flow of product at the dispenser when it detects a leak <br /> 14 CCR 2631(a) Primary containment is not product tight <br /> 15 HSC 25291(a)(2) Secondary containment for UST system is not tight <br /> 16 CCR 2636(c)(1) All releases in secondary piping do not If to a collection sump <br /> 17 HSC 25291(f) Line leak detector(s)not installed (M1) <br /> 18 CCR 2635(b)(1) Spill container not installed,failed to contain a minimum rapacity of five gallons,or failed to provide (M2) <br /> a means to keep the spill container empty <br /> 19 CCR 2635(b)(2) Overfill prevention system was overridden or failed to meet overfill requirements in this section (M2) <br /> 20 CCR 2636(a) Failed to have secondary containment or continuous monitoring(includes conventional suction piping) <br /> 21 HSC 25291(e) Water in 21 containment not removed,analyzed&property disposed of <br /> Unauthorized release that: (c)did not escape secondary containment and cleaned up within eight hours (M1) <br /> 22 CCR 2650 was not recorded;(e)escaped secondary containment,not cleaned up after eight hours,or a sudden loss of <br /> product was not reported to the EHD within 24 hours <br /> 234 I CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days <br /> 23b CCR 2715(b) Designated operator did not possess a current ICC UST System Operator certification <br /> Designated operator monthly inspection:(c)(1)alarms not documented;(c)(2-4)spill containers,UDCs,and <br /> 23c CCR 2715(c).(d),(e) sumps(if necessary)not inspected;(c)(5)required test dates not checked or noted;(c)(6)employee training not <br /> verified; (d)(e)monthly inspection reports not maintained on site for at least 12 months <br /> 23d CCR 2715(f) Designated operator employee training:(1)not performed; (2)not current for at least one employee on site;(3) <br /> log not ke t <br /> EHD INSP R: IVED Y: TITLE- <br /> EHD 23-02-002 REV 12109 Page 1 UST INSPECTION REPORT <br />