My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013 - 2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARDING
>
244
>
2300 - Underground Storage Tank Program
>
PR0231137
>
COMPLIANCE INFO 2013 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/13/2019 2:50:46 PM
Creation date
11/5/2018 12:44:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2015
RECORD_ID
PR0231137
PE
2361
FACILITY_ID
FA0001554
FACILITY_NAME
MIRACLE MILE MARKET
STREET_NUMBER
244
Direction
W
STREET_NAME
HARDING
STREET_TYPE
WAY
City
STOCKTON
Zip
95204
APN
13708014
CURRENT_STATUS
01
SITE_LOCATION
244 W HARDING WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\H\HARDING\244\PR0231137\COMPLIANCE INFO 2013 - 2015.PDF
QuestysFileName
COMPLIANCE INFO 2013 - 2015
QuestysRecordDate
7/21/2016 11:31:35 PM
QuestysRecordID
3150426
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
103
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
v SAN JOAQUIN COUNTY ...i <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sioov.orcl/ehd <br />CONTINUATION FORM <br />Page: 4 of 5 <br />OFFICIAL INSPECTION REPORT <br />Date. 05/30/14 <br />Facility Address: 244 W. Harding, Stockton <br />Program: UST <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Comply) <br />109, 110, & 111. Annual monitoring system certification, leak detector testing, and spill container testing <br />were last performed on and was due by January 2014. Testing has not been completed and is 4 <br />months past due. These tests are required once every 12 months. Immediately schedule these tests <br />and provide 48 hours notification to the EHD. Please be aware that a follow up inspection will be <br />charged at our current hourly rate. <br />119 & 317. This UST system was found to be illegally abandoned. No person shall abandon an UST <br />system without complying with the requirements of HSC 25298. Sukhwinder Singh, the current tank <br />owner, states the UST system will be reused. Immediately obtain a permit from the EHD to temporarily <br />close this UST system. A permit application to temporarily close the UST system has been submitted to <br />EHD on May 29, 2014. <br />201. Maintenance and monitoring records were not found on site. These records shall be kept on site <br />for at least 3 years. Immediately locate and maintain the on site and submit copies to the EHD. <br />204. Facility does not have a designated operator since March 2014, and has not documented any <br />alarms nor checked that they were responded to appropriately since that time. During the monthly <br />inspection, the designated operator shall review the alarm history for the previous month, check that <br />each alarm was documented and responded to appropriately, and attach a copy of the alarm history with <br />documentation taken in response to any alarms to the monthly report. Ensure that designated operators <br />performing monthly inspections at this facility are including all of the required information on the reports. <br />205. Designated operator monthly inspection reports were not found on site. Designated operator <br />monthly inspection reports for the previous twelve months shall be retained on site. Locate the previous <br />twelve months of reports, maintain them on site, and submit a copy to EHD immediately. <br />206. The designated operator employee training was not performed . The designated operator shall <br />train facility employees for which he or she is responsible in the proper operation and maintenance of <br />the UST system once every 12 months. The training shall include, but is not limited to: <br />1. Operation of the UST system in a manner consistent with the facility's best management practices <br />2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br />3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br />4. Name of the contact person(s) for emergencies and monitoring equipment alarms <br />Ensure that employees have been trained by the designated operator, maintain the list on site, and <br />immediately submit a copy of the training records to the EHD. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANYTIME AT EHD'S CURRENT HOURLY RATE. <br />EHD Inspector: <br />Received B : <br />Title: <br />Jeffrey Wong (209)468-0335 <br />EHD 23-02-003 Rev 04/19/12 CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.