EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
15688
>
2300 - Underground Storage Tank Program
>
PR0527026
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/28/2021 11:40:43 AM
Creation date
11/5/2018 12:57:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0527026
PE
2361
FACILITY_ID
FA0018313
FACILITY_NAME
JOES TRAVEL PLAZA
STREET_NUMBER
15688
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
19620077
CURRENT_STATUS
02
SITE_LOCATION
15688 S HARLAN RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\H\HARLAN\15688\PR0527026\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
5/14/2013 8:00:00 AM
QuestysRecordID
159488
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
04/17/2007 09:24 916-371-1172 <br /> WALTON ENGINEERING PAGE 03 <br /> D°� SI3(o7 M�ryjt�ank) <br /> 7IB`7UNIk'IEA PROGRAM CONSOLIDATED FORMTANKS `� Ji07 UNDERGROUND STORAGE TANKS - TANK (Two Pagn?P <br /> Page I of <br /> TYPE OF ACTION ❑ 1.NEW PERMIT ❑ 4,AMENDED PERMIT ❑ 5,CHANGE OF INFORMATION ❑ 6.TEMPORARY TANK <br /> cw$vISE 45n <br /> (Check ors nam onlyl ❑ 3.RENEWAL PERMIT ❑ 7.PERMANENTLY CLOSED ON SITE <br /> (.sm-Ify mnnan) (Spwy ranean) ® 8.TANK REMOVF,O <br /> BUSINESS NAME 15"m FACILITY NAME or DBA-Deng 0.11..,M) 3 FACILITY ID' <br /> Joe's Travel PlazaI <br /> LOCATION <br /> a <br /> O� D� 451. <br /> I. TANK D.tSCR;IMOrit - <br /> �7od l6l 19n vJithil rhe YJ57'' <br /> P TANKIMANUFACTURF?R g idiN hn-433 <br /> d'�Ikntl1518hM ARTMENTALIZmm N1 1agE6 <br /> TA <br /> TANK ID it d71, g stein mcludln bU'i„ gY 'rothN IoCh <br /> K Yet; No 434, <br /> na5le1ulilcIOW13 (Y."eomplme one pn9a It"eachp4nmmn. <br /> DATE INSTALLED 4,15, TANK CAPACITY IN GAI.,LONS 476_ NUMBER OF COMPARTMENT- <br /> -(YEAR/MO) 431, <br /> Unknown 500 1 <br /> ADDITIONAL DESCRIPTION(Far l.iJ me only) 418 <br /> TANK USE mo. PETROLEUM TYPE . <br /> ❑ 1. MOTOR VEH)CLEFUEL ❑ In. REGULAR UNLEADRD ❑2. LEADED +4n <br /> ❑5. TET FIJEI. <br /> (Ifeheekad,mmplete Pmrolmm Type) ❑Ib. PREMTIM UNLEADED 03. DIESEL <br /> [:12. NON-FUEL PETROLEUM ❑6. AVIATION GAS <br /> ❑1c, MIDGRADE UNLEADED ❑4, GASOHOL 099.OTHER;Unknown <br /> ❑ 3. CHEMICAL PRODUCT COMMONNAME (hill 1441,1RINlMmerinle lnv tmy pegs) 441. CA'SO Hnznrdeun Mmndnl,,lmmnwry paW:J 447. <br /> ❑ 4. HAZARDOUS WASTE URICnown <br /> (Includes used ol6 <br /> ® 95.UNKNOWN <br /> ' �'Akll�CfINS"iiRl#7ETION. <br /> TYPE•OF TANK <SI 1. SINGLE WALL ❑3. STNOI,E WALL WITH EXTERIOR ❑V SINGLE WALL WITH INTERNAL BLADDER SYSTEM 141. <br /> (Check me item only) MEMBRANEL(NER CI 05. UNKNOWN <br /> [32 DOUBLE WALL ❑4, SINGLE WALL 1N A VAULT El 99. OTHER <br /> TANKMATBRIAL_pdmmymrk 201, BARE STEEL LJ 3. FIBERGLASS/PLASTIC 0 3. CONCRETE El 95.UNKNOWN 444. <br /> (Cheep one imm only? ❑2. STAINLESS STEEL ❑4, STEEL CLAD W/FIBERGLASS ❑a, FRP COMPATIBLE ❑99,OTHER: <br /> REINFORCED PLASTIC(FRP) W/100%h4ETNANOL <br /> TANK MATERIAL-8ccondnry look 1, BARE STEEL ❑3. FIBERGLASS/Pl„ASTIC S, FRPCOMPTIBLE W/IoOak METHANOL CI 96,UNKNOWN 445. <br /> (Check one itcm only) ❑2. STAINLESS STEEL ❑4. STEEL CLAD W/FMERGLASS ❑9. FRP NON-CORRODABLE JACKET ❑99,OTHER <br /> REINFORCED PLASTIC(FRP) ❑10. COATED STEEL <br /> ❑S. CONCRETE <br /> TANK INTERIOR LINING ❑1.RUBBER LINED ❑3.EPDXY LINING S.CLASS LINING 95.UNKNOWN 446, DATE NSTALI..F.O ul. <br /> OR COATING ❑2,ALKYD LINING ❑4.PHENOLIC LINING ❑6,UNLINED [199.OTHr; <br /> Check one item only) <br /> OTHER CORROSION ❑L MANUFACTURED CATHODIC 0.1.FIBERGLASS REINFORCED PLASTIC ®95.UNKNOWN as. DATE INSTALLED a9. <br /> PROTECTION PROTECTION 04.IMPRESSED CURRENT CI 99.OTHER <br /> I(A liublc ❑2.SACRIFICIAL ANODE <br /> SPILI.AND OVERFILL YEAR INSTALLED 450. TYPE del. OVERFILL PROTECTION EQUIPMENT: YEARINSTALLED 45X. <br /> (Check all that apply) ❑ I.SPILL CONTAINMENT Unknown ❑I.ALARM ❑3,FILL TUBE SHUT OFF VALVE Unk <br /> ❑2.DROP TUBE Unknown ❑2.BALL FLOAT Q 4.EXEMPT <br /> ❑3.STRIKER PLATE Unknown <br /> .TAN LSA I1ETIE CT£ION <br /> ..... ' (.hAb4ctl�fibR nf,rhd nmitiitoindgpr '911NL'ElrisBhlnitiid:�aTlre:rom131 � ;.:; <br /> IF SINGLE WALL TANK 453. TF DOUBLE WALL TANK OR TANK WRH BLADDER 454 <br /> (Cbxk all that apply) (Cbmk me Item only) <br /> ❑I. VNIIAL(EXPG$ED PORTION ONLY) El 3.MANUAL TANK OAUGNO(INTO) ❑I,VISUAI,.(SINGLE WALL IN VAULT ONLY) <br /> ❑2. AUTOMATIC TANK GAUGING(ATG) ❑6,VADOSE ZONE ❑2,CONTINUOUS INTERSTITIAL.MONITORING <br /> ❑3.CONTINUOUS ATG ❑7.OROUNDWATER ❑3.MANUAL MONT rORING <br /> ❑4, $TATM. ICAC.INVENTORY RECONCILIATION 0 S.TANK TF_STINO <br /> (SIR)+BIENNIAL TANK TESTING ®99.OTHER Unknown <br /> ty TANI9 CLOSM- NI ORMATION L ANENT CL09UIii!)E IN PLACR <br /> 1?FII1 ' <br /> ESTIMATED DATE LAST USED(YRM10/DAY) 455ESTIMATED OUANTITY OFSURgTANCE REMAINING 4stt 1 TANK FILLrD WITH INERT MATERIAL? 457 <br /> g.111.` ❑Yes ❑ No <br /> UPCFhwrwrc-b(1/99)-1/4 httpOwww.anldoucirg Rev.02/16/MI <br />