My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
15688
>
2300 - Underground Storage Tank Program
>
PR0527026
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/28/2021 11:40:43 AM
Creation date
11/5/2018 12:57:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0527026
PE
2361
FACILITY_ID
FA0018313
FACILITY_NAME
JOES TRAVEL PLAZA
STREET_NUMBER
15688
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
19620077
CURRENT_STATUS
02
SITE_LOCATION
15688 S HARLAN RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\H\HARLAN\15688\PR0527026\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
5/14/2013 8:00:00 AM
QuestysRecordID
159488
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
04/17/2007 09:24 916-373-1172 <br /> WALTON ENGINEERIM1(G O 9�S-��IOPAGE�KIZ ���D,7, <br /> UNIFIED PROGRAM CONSOLIDATED FORM [ll <br /> TANKS <br /> UNDERGROUND STORAGE WANKS - TANK PAGE 2 <br /> ;'.';VUi•YI 1NG'CONS7'R'FI(,Td(ON' urli9rc', P 2of2 <br /> UNDEROROUND PIPING ABOVEGROUND PIPING <br /> SYSTEM TYPE ❑1,PRESSURE Q 2,SUCTION ❑3.GRAVITY 459. ❑ [,PRESSURE ❑2,STICTION ED.GRAVITY 459. <br /> CONSTRUCTION/ Q I.SINGLE WALL Q 3,LINED TRENCH ❑99,OTHER 460, Q I,SINGES WALL ❑95. 462. <br /> UNKNOWN <br /> MANUFACTURER <br /> 2.DOUBLE WALL ®95.UNKNOWN Q 2.DOUBLE WALL Q 99.OTHER <br /> MANUFACTURER Unknown 4M1I. MANUFACTURER 4m. <br /> 0 1.BARE STEEL 116,FRP COMPATIBLE W/100%METHANOL ❑L BARE STEEP ❑4 FRP COMPATIBLE W/100%METHANOL <br /> 0 2,STAINLESS STEEL Q 7.GALVANIZED STEEL 0 2,STAINLESS STEEL Ll 7.GALVANIZED STEEL. <br /> ❑3.PLASTIC COMPATIBLE"TIT CONTENTS [195.UNKNOWN ❑3.PLASTIC COMPATIBLE W/CONTENTS ©a.FLEXIBLE(HOPE) ❑99.OTHER <br /> ❑4.FIBERGLASS ❑8,FLEXIBLE(HOPE) Q 99.OTHER Q 4.FIBERGLASS ©9.CATHODIC PROTECTION <br /> ❑5.STEEL W/COATING Q 9.CATHODIC PROTECT70N 454, Q 5,STEEL W/COATING Q 96.UNKNOWN 465. <br /> VII'.'PIPING'L '.'Y{i' F'iT'ECTION'EiNRNII YhnI:A I.'A21 Yro69Tmemcmic' ro' Po'd1inll5ebmirieede dte taal'- <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WAIL PIPING 466, SINGLE WALL PIPING 467, <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> ❑L ELECTRONIC LINT LEAK DETECTOR 3,0 OPH TEST WITk3 AUTO PUMP Q I. F;LECTRONIC LINE LEAK DETECTOR 3.0 GPM TEST V=AUTO PUMP <br /> SHUT-OFF FOR LIjAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION SHUT OFF FOR LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION <br /> +AUDIBLE AND VISUAL ALARMS. +AUDIBLE AND VISUAL ALARMS. <br /> E12. MONTHLY 0,2 OPH TEST ❑2. MONTHLY 0.2 GPM TEST <br /> 03. ANNUAL INTEORITYTEST(0.1 GPM) ❑3, ANNUAL INTEGRITY TEST(0.I QFH) <br /> ❑4. DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS CONVENTIONAL SUCTION SYSTEMS(Chock all that apply) <br /> Q 5. DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIAL PIPING Q5. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> INMORITY TEST(0.1 GPM) <br /> SAFE SUCTION RVSTEMS(NO VALVES IN BELOW GROUND PIPING): Q 6. TRIENNIAL INTEGRITY TEST(0.1 GPM) <br /> Q 7 SELF MONITORING SATE SUCTION SYSTEMS(NO VALVES M EFLOW GROUND PIPING): <br /> GRAVITY FLOW Cl 1, SELF MONITORING <br /> Q% OIENNIAL TNTEGRITY TEST(al GPM) GRAVITY FLOW(Check all That APply)i <br /> 08. DAILY VISUAL MONITORING <br /> C39. BIRNNIAL INTEGRITY TEST(0.1 GPM) <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(rhook all that apply): PRESSURIZED PIPING(Check an that apply): <br /> 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ID. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL <br /> ALARMS AND(Check one) ALARMS AND(Check one) <br /> Q p, AUTO PUMP SHUT OFF WHEN A LEAK OCCURS Q a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> [3b AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE.AND SYSTEM Q b.AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM <br /> DISCONNECTION DISCONNECTION <br /> NO AUTO PUMP SHUT OFF r3e, NO ALTO PUMP SHUT OFF <br /> 011. AUTOMATIC LINE LEAK DETECTOR(3.0 OPH TEST)0W FLOW SHUT 011 AUTOMATIC LEAK DETECTOR <br /> OFF OR RESTRICTION <br /> [112, ANNUAL INTEGRITY TTST(0,1 GPM Q 12,ANNUAL INTEGRITY TTST(O,I GPM) <br /> SUCTION/GRAVITY SYSTEM SUCTION/GRAVITY SYSTEM <br /> ❑U. CONTINUOUS SUMP SENSOR+AUDn3f F.AND VISUAL ALARMS ❑13.CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check PIT that apply) EMERGENCY GF.NRRATORS ONLY(Check all that apply) <br /> Q14. CONTINUOUS SUMP SENSOR I)tg'TJgW AUTO PUMP SHUT OFF Q14. CONTINUOUS SUMP SENSOR WITMOIlT AUTO PUMP SHUT OFF <br /> AUDIBLE AND VISUAL AI..ARMS AUDIBLE AND VISUAL ALARMS <br /> 015. AUTOMATIC LINE LEAK DETECTOR (AO OPH TEST) Y/J.ULQU2 FLOW Q 15. AUTOMATIC LINE LEAK DFTFCTOR(3,O GPH TEST) <br /> SHUT OFF OR RESTRICTION <br /> 010, ANNUAL INTEGRITY TEST(0.1 OPH) Q 16. ANNUAL INTEGRITY TEST(D.I GPH) <br /> Cl 11, DAILY VISUAL CHECK Cl 17, DAILY VISUAL CHECK <br /> 'W'h'.I:If1SPE'1VJE1k'!�f11!1T'AdTVMCY41`I'. <br /> DISPENSER CONTAINMENT 461. QI. FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE 04. DAILY VISUAL CHECK 4w. <br /> DATE INSTALUiO Q2. CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS Q5. TRENCH/LINER MONITORING <br /> N/A ❑3. CONTINUOUS DISPENSER PAN SENSOR WM AUTO SHUT OFF FOR 06 NONE <br /> DISPENSER+AUDIBLE AND VISUAL ALARMS <br /> 174 OIVNMOPETUTOR.SI0'NATIIRP, <br /> I certify that c infomaort prnvided her9in is trot gd accurate to the ben of my knowledge <br /> SIGNATt1RF: F DATE:4/16/07 °N1 <br /> NAME OF ANERIOPERAToR(pdat); Michael E. Walton TITLE OF OWNER/OPERATOR: Contractor <br /> Ponnit Number(Agency car only) 473, Ponnii Approved By(Agency ace only) 474. Permit Eapustion Date(Agency use only) 475. <br /> UPCP hwfwmb(It")-314 http://m w.Pnidom.oig Rev 02/16/00 <br />