My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HOOD
>
5655
>
2300 - Underground Storage Tank Program
>
PR0540345
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/17/2021 2:44:41 PM
Creation date
11/5/2018 1:13:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0540345
PE
2351
FACILITY_ID
FA0023065
FACILITY_NAME
FedEx Ground - Tracy
STREET_NUMBER
5655
STREET_NAME
HOOD
STREET_TYPE
Way
City
Tracy
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
5655 Hood Way
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\H\HOOD\5655\PR0540345\COMPLIANCE INFO 2016 - PRESENT.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
297
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
v Alert <br /> lat <br /> San Joaquin County <br /> Environmental Health Department <br /> East Hazelton <br /> e. Stockton, <br /> MT <br /> f ILE(l t elephone 209 )468 3420 Fax:(209) 468-3 331fornia 95205-6232 <br /> Web:vvv siaov ora/ehd <br /> �I Underground Storage Tank Program Inspection Report <br /> Facility Name: Facilhy Phone: Date: <br /> FedEx Ground-Tracy (2 09)839-2000 August 26, 2016 <br /> Facility Address: CERS to <br /> 5655 Hood Way, Tracy, CA 95377 10689070 <br /> Inspection Contact: Title: Phone: <br /> Gaylyn Frosini Manager-Env Services (412)262-7375 <br /> Inspection Type: Program: <br /> ROUTINE INSPECTION-Operating Permit 2351 - UST FACILITY-2481 COMPLIANT <br /> Consent For I Consent Given By: <br /> ❑ Inspection ❑ Photos Sample <br /> Service Technician Ck ib: Exp.Dab: =atedl Operator. Exp.Data: <br /> Dafen Saume 06!09/2018 Shawn Rodriguez 05/0 412 01 8 <br /> Service Technician Nanubchoai s Training: <br /> Veeoer Root, 05/04/17 <br /> CCR=Calmme Code of Regulations HSC=Hea,.n and Salary Cafe CFR:Code of Fednel Rng.lfncrs <br /> V-V,.I.tlon R Repeat vidistort COS a Corrected on are during rape.,. <br /> Fills Review <br /> 101 HSC 25264 No permit to operate to V o R o COS <br /> 102 HSC 25284(x)(3) No written agreement Definition tank carrier and tank operator to monitor the tank system o V a R a COS <br /> 103 HSC 25292 2 Current financial responsibility documents rot submitted o V to R c COS <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current a V a R c COS <br /> 105 CCR 2832(d)(1) Failed to have an approved UST monitoring plan o V o R a COS <br /> 106 CCR 2632(d)(2) Failed to have an approved UST response plan o V o R a COS <br /> 107 CCR 2632(d)(1)(C) Plot planlste map not submitted or tatted to compost show where monitoring is performed a V a R a COS <br /> 108 CCR 2637(n.2838(e) Failed o notify the EHD 48 hours prior to conducting testing o V c R o COS <br /> 109 CCR 2637 Failed to test secondary containment to V o R o COS <br /> 110 CCR 2837x) Failed to submit secondary containment test report within 30 days to V o R to COS <br /> 111 CCR 2838(a) Failed to fast monitoring and leak detection equipment annually o V a R to COS <br /> 112 HSC 25294.2 Failed to test spill containers annually o V a R a COS <br /> 113 CCR 2838(d) Failed to submit monitoring system cartdication test report within 30 days o V a R in COS <br /> 114 CCR 2836(f) Failed to perform 0.1 gph annual ilne test for pressured piping without fail sale or shut down o V a R o COS <br /> 115 CCR 2715(a) Failed to inform the EHD of designated operelor identification or change within 30 days o V o R o COS <br /> 116 CCR 2715 Designated operator,service tech or Installer did not possess current ICC tartificancn a V o R a COS <br /> 117 CCR 2983 Failed to Inspect alined or repaired steel tank within 10 years of lining and every 5 years after o V o R o COS <br /> 118 CCR 2663 Failed to submit lank lining certification within 30 days or to conduct proper teats _.V o R o COS <br /> 119 HSC 25299 Documents were falsifed or misrepresented o V n R o COS <br /> 120 CCR 2635(d) Failed to submit UST Certification of InstallatiorWo irfici is n o V a R o COS <br /> 121 CCR 2712(0 Fattao to submit a written response within 30 days of ritaaiving an inspection report a V o R o COS <br /> 122 CCR 2631 U) Failure to submit UST system component statement of mmpalioll,y for substance stored o V o R o COS <br /> On Skit Reeorfh <br /> 201 CCR 2712(b) Failed to maintain alarm logs andlor records of it up actions n V to R a COS <br /> 202 CCR 2712(b) Felled o ma ratan cathodic protection test records on Ste for at least 6 112 year _i V to R a COS <br /> 203 CCR 2712(b) Faded to maintain records of monitoring,repairfining,and upgrades on site V o R o COS <br /> Page 1 of 4 <br /> 071 96W 0935 0118 0895 04 <br />
The URL can be used to link to this page
Your browser does not support the video tag.