My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HOOD
>
5655
>
2300 - Underground Storage Tank Program
>
PR0540345
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/17/2021 2:44:41 PM
Creation date
11/5/2018 1:13:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0540345
PE
2351
FACILITY_ID
FA0023065
FACILITY_NAME
FedEx Ground - Tracy
STREET_NUMBER
5655
STREET_NAME
HOOD
STREET_TYPE
Way
City
Tracy
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
5655 Hood Way
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\H\HOOD\5655\PR0540345\COMPLIANCE INFO 2016 - PRESENT.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
297
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1866 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web-'www.si0ov ora/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Fauuty Address Data: <br /> FedEx Ground-Tracy 5655 Hood Way. Tracy August 26, 2616 <br /> On Site Records <br /> 204 CCR 2712(1) Current monitoring plan approved by the EHD not found on ale o V a R o COS <br /> 205 CCR 2712(1) Failure to have an approved UST response plan available onarte o V OR o COS <br /> 206 CCR 2712 Failure to comply with UST operating permit conditions o V a R o COS <br /> 207 HSC 28294 Failed to record unaulhor¢ed release from pnrtatry containment a V o R a COS <br /> 208 CCR 2650(e) Failed to notify the EHD of a reportable unauthorized release o V a R a COS <br /> 209 CCR Z715(c) Designated obis r did not inspect all required items and/or Oro Inspection reports not completed o V o R a COS <br /> 210 CCR 2715(e) Designated operator monthly inspection reports not maintained on site for at heat 12 months o V o R o COS <br /> 211 CCR 2715(f) Designated operator employee training not performed or log not kept o V o R a COS <br /> 212 CCR 2715(0(2) Unstaffed facility faded to have or Implement a training program approved by the EHD a V a R o COS <br /> 213 MSC 25281.5(b)(2) Unburied fuel piping at marrow not visually inspected at least daily or log not kept o V o R o COS <br /> 214 HSC 25281 5(b)(3) Unburied emergency generator fuel piping not visually inspected at least monthly or log kept o V c R o COS <br /> UST System Observations <br /> 3Ul HSC 25292 t UST system is not operated to prevent unaumonzed release,including spills and overfills a V o R c COS <br /> 302 MSC 25291(b) UST system incapable of detecting leek from primary into secondary containment(pre-Jul 2003) o V a R o COS <br /> 303 HSC 25290.2(d) Monitoring system not maintained to detect entry into secondary containment(Jul 200&Jun 2004) a V a R a COS <br /> 304 HSC 252N I(d) Monitoring system not membered to bell entry Into Secondary containment(after Jul 2004) o V a R o COS <br /> 305 HSC 25290.1(a) VPH monitoring of the Interstitial spaces of the UST system is not maintained a V o R o COS <br /> 306 CCR 2830(d) Monitoring equipment is not installed or maintained to select a leek at Me sorriest opportunity o V o R c COS <br /> 307 CCR 2632(c) Monitoring system of the interstitial space of a double walled system not maintained o V u R o COS <br /> 308 CCR 2838(0 Failed to maintain a continuous monitonng system that activates an audible and visual alarm a V o R a COS <br /> 309 CCR 2636n)(1) Monitoring in sump I UDC failed to activate an audible and visual alarm or stop the Eva product o V o R o COS <br /> 310 CCR 2836(f)(5) Piping is not fail-sale outside DOCS or fails to atop Bow of product at dispenser inside UDCs o V a R a COS <br /> 311 CCR 2538(a).26410) Failed M property program or operate leak detection equipment a V o R o COS <br /> 312 CCR 2838(0 Failed to aMx a tag sticker on monitoring equipment penciled repaired,or replaced o V a R a COS <br /> 313 HSC 25290.1.25290 2, Failure to construct,operate,and maintain primary containment as product-tight o V o R o COS <br /> 25291 <br /> 314 HSC 252901.25290 2, Failed to have secondary containment or secondary containment not tight o V o R o COS <br /> 25291 <br /> 315 HSC 25291(a) Water in secondary containment nit removed,analyzed,and properly disposed of(pre-Jul 2003) o V o R o COS <br /> 316 HSC 25290.1(c3), Secondary containment not constructed to prevent water intrusion(after Jul 2003) a V o R a COS <br /> 25290.2(c3) <br /> 317 CCR 2838(0(2) Line leak detector nit installed o V o R o COS <br /> 318 CCR 2638(0(2) Leak detector failed to detect a 3.0 gich leak at 10 poi o V is R a COS <br /> 319 CCR 2635(b) No spill bucket failed to contain five gallons,or failed to pmvde a moans to keep it smpty, o V o R o COS <br /> 320 CCR 2635(b)(2) Overfill prevention system not present or failed to meet oveTill requirement o V a R or COS <br /> 321 CCR 2635(b)12; Overall prevention was overridden o V a R o COS <br /> Page 2 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.