Laserfiche WebLink
Man-Out-of-Hole (MOH) Straps Instructions <br /> 1.GENERAL 2.3.1.2. If using deadmen other than Xerxes deadmen,check align- <br /> 1.1.These instructions for installation of anchors and straps do not ment of all anchor points to insure that they are within a tolerance of <br /> require a person to enter the hole while installing the anchor straps. ±1 inch. <br /> They supplement the Anchoring Tanks Section of the Xerxes Note:The anchor point must be a minimum of 3 inches over <br /> Installation Manual and Operating Guidelines(subsequently referred the top of the deadmen to accommodate the strap hook. <br /> to as"Installation Manual"). 2.3.1.3.Always provide sufficient clearance to allow the deadmen to <br /> 1.2.Before beginning the tank installation and installing tank hold- be set outside of the tank"shadow."See Tank Spacing subsection in <br /> down straps,read through the entire Installation Manual. Installation the Excavation Parameters section of the Installation Manual.(See <br /> instructions are also laminated onto each tank. FIGURE 2-1.) <br /> 1.3.It is the responsibility of the owner,installer and operator to <br /> comply with all federal,state and local laws,regulations,codes and <br /> safety precautions. <br /> 1,4.It is important to follow the procedures and instructions in the <br /> Tank <br /> Installation Manual in order to safely and properly install a Xerxes ---MOH strap <br /> underground storage tank and accessories. Failure to follow those <br /> instructions will void the tank warranty and may cause tank failure, <br /> death,serious personal injury or property damage. an s eAncno ofnt <br /> 1.5.Xerxes must authorize, in writing and prior to tank installation, a p; si as <br /> any variation to,or deviation from,the Installation Manual and the a- eaaman <br /> Man-Out-of-Hole Straps Instructions. <br /> 1.6.All correspondence regarding variations must be retained for <br /> any warranty claim to be valid. <br /> 1.7.If you have questions or encounter situations not covered in FIGURE 2.1 <br /> these installation instructions,contact technical support at Xerxes 2.3.1.4. The top of the deadmen should be aligned to the bottom of <br /> Minneapolis,952-887-1890. the tank. <br /> 2.ANCHORING TANKS 2.3.3. Position the deadmen so they are parallel with the centerline <br /> CAUTION of the tank.(See FIGURE 2-2.) <br /> Failure to follow this document's instructions on proper place- Load binder <br /> went of hold-down straps,deadmen and anchor slabs may dam- —� assembly <br /> I I I I- �I <br /> age the tank,cause property damage and void the tank warranty. I I <br /> 2.1.Hold-Down Straps —VIII I=VII <br /> 2.1.1.Only Xerxes straps may be used when anchoring a Xerxes <br /> tank. Ill=III str°P I IIII <br /> 2.1.2.The only allowed locations for hold-down straps on each tank I I 1 ,� III—III I <br /> are marked on the tank by the arrowhead symbols ►�. IIII I 11;€ <br /> 2,1.3. Straps must be used on all marked hold-down locations. —I IIII I II m- II II <br /> CAUTION I—IIII $� hook ;%. IIII <br /> 8'°� d aEBoq.•°°•°�e`B`°`°'°`°°"°`°'°`&o0 08 <br /> n d °..866886888:8°8°"988 t7 bed °88=6 <br /> Do not place straps between ribs(except on 4-faot-diameter I 115 8868 8888 88H•8o8aFe686°.°. 4^8=.�e8d <br /> �— � — � <br /> tanks).Failure to properly place straps may result in tank damage. <br /> 2.2.Backfill Material FIGURE 2-2 <br /> 2.2.1.Xerxes tanks must be installed with backfill material as 2.3.4. Place backfill between deadmen,and level backfill so it is 12 <br /> described in the Backfill Material Section of the Installation Manual. inches deep. <br /> 2.2.2. Using other than approved backfill material without prior writ- 2.3.5.When setting the tank,make sure that the tank is aligned with <br /> ten authorization from Xerxes will void the tank warranty. the deadmen. <br /> 2.3.headmen 2,4.Anchor Slab <br /> 2.3.1.Align the deadmen with the tank. 2.4.1. If an anchor slab is used,align(within a tolerance of±1 inch) <br /> 2.3.1.1. If using Xerxes deadmen,align(within a tolerance of±1 inch) the anchor points on the anchor slab with the marked arrowhead <br /> all anchor points with the marked arrowhead symbols►t on the tank. symbols ►J on the tank. <br /> AEMES® <br /> CORPORATION <br /> 7901 Xerxes Avenue South, Minneapolis, MN 55431-1288 a (952)887-1890 ■ Fax(952)887-1882 ■ wvvw.xerxescorp.com <br /> 2007 Xerxes Corporation xmhl 1/07ih <br />