Laserfiche WebLink
Flying J Travel Plaza #618, 1501 N. Jack Tone Rd., Ripon CA, 95366 — SR0068444 <br /> Response received: Signed buoyancy calculation to be submitted with this resubmittal. <br /> t <br /> Deficiency corrected. <br /> 8. The installing technician's manufacturer training certifications for all components being <br /> installed, as well as, any other worker who may install components and is required to be <br /> certified by the manufacturer (i.e., spill containers, primary and secondary piping, double <br /> walled UST and sumps, sump penetrations, overfill prevention, flex piping, and liquid <br /> sensors) were not submitted. All required applicable certifications for an individual <br /> certified by The International Code Council (ICC). <br /> First response received: None <br /> The contractor for this project has not been chosen. In order for an approval letter to be <br /> issued, information for the contractor that will be utilized for this proposed project must <br /> be received. Provide a complete package of all of the required certifications of the <br /> t: <br /> installing contractor. MRB does not have all of the required certifications and the <br /> approval letter cannot be issued to them. See item #9. <br /> Certifications for Jones Covey Group, Inc. were submitted. However, certifications are <br /> still required for Xerxes, OPW, NEF (If available), Bravo, and Veeder Root, as well as, <br /> any other certifications offered by manufacturers of equipment being utilized on this <br /> project. <br /> 9. A Hazardous Substances Certification as required by the California Business and <br /> a <br /> Professionals Code, section 7058.7(e) was not found for the contractor's license for <br /> MRB General Contracting Inc., license 817269. r <br /> Response received: None. <br /> A Hazardous Substances Certification for Jones Covey Group, Inc. was submitted. ; <br /> 10. Sheet PP1.1 lists the tank interstitial sensor as a "301" and sheet PP4 lists it as a "303. <br /> The EHD requires that a high/low level sensor such as the "303" be utilized. <br /> Response received: Design is for a VR-303 sensor to be used. Item number error is on <br /> sheet PP2.1 and will be updated to VR-303 dual level sensor. <br /> The corrected sheet was received. <br /> 11. Further review and consultation with the California State Water Resources Control Board <br /> will be requested for the final approval of this project. The EHD will notify you <br /> immediately if other revisions and/or changes will need to be made to the plans. <br /> No information has been received from the CA State Water Resources Control Board. <br /> 5 <br />