My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2006 - 2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
800
>
2300 - Underground Storage Tank Program
>
PR0231349
>
COMPLIANCE INFO 2006 - 2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/21/2021 4:57:32 PM
Creation date
11/5/2018 3:55:32 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006 - 2007
RECORD_ID
PR0231349
PE
2351
FACILITY_ID
FA0003633
FACILITY_NAME
ARCO 07049
STREET_NUMBER
800
Direction
E
STREET_NAME
KETTLEMAN
STREET_TYPE
Ln
City
Lodi
Zip
95240
APN
06206042
CURRENT_STATUS
01
SITE_LOCATION
800 E Kettleman Ln
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\K\KETTLEMAN\800\PR0231349\COMPLIANCE INFO 2006 - 2007.PDF
QuestysFileName
COMPLIANCE INFO 2006 - 2007
QuestysRecordDate
2/16/2018 6:39:17 PM
QuestysRecordID
3798594
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
123
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br /> f <br /> i <br /> . t # <br /> i <br /> iWMEUNDERGROUND STORAGE TANK <br /> MONUORING PLANT—PAGE 2 <br /> ,..AREAS BENEATH DISYA`I5ER(S)TS PERFORMED(TSINU THE FOI LOWING A2EITi00(S)(Check all that apply)USELECTROMCMONIIORINGCTtJNDERDISPENSERCONTAINMENT(UDC)ANUFACIURER:__.—VVeederRoo Msr MODEL#: TTS350 .. M54ENSOR MANUFACTURERR: Veeder Ront � MODE.I(S):. 74-380-323M�TECTION OF A LEAK INTO THE UDC TRIGGER AUDIBLE AND VISLJAI ALARMS? 0 a YES ❑b NO adss <br /> WILI AUDCIEAKALARMIRIGGfiRAUT'OMAIICPUMPSHUTDOWN? a YES El b NO Ms6 <br /> WILL FAILUREXISCONIVECHONOF UDC MONITORING SYSTEM TRIGGER AUTOMAIIC PIJMFP SHUIDOWN7 iq 01 a YES ❑ b I MS3 <br /> E7 2 MECEANIICAL ASSEN113L Y(e g,FLOAT AND CHAIN ASSEMBI Y)IN UDC IRIPS SHEAR VALVE IN CASE Of TEAK ! <br /> M5a MODEL u59 j <br /> ASShMBLYMANItFACIURER_ _— _--_---- (}.—_ ---— reap <br /> L]3VISUAL MONITORINGDONE: Ej aDALY ❑ b WEEKIYIttequirae¢geoerapp—J) 1 <br /> ❑ 4 NO DISPENSERS Mdl i <br /> ❑ <br /> 99.OTHER(Specify) _ --- — — — + <br /> �•,::....�..!_r. 7�!��_:'}:i�'�i.•. -. ��L�(,�LL„ 1sL", .����4+�!1-lk •? <br /> ..: .::. <br /> -❑ 1 WE HAVE BFEN NOTIFIED BY THE STATE`NATER RESOTIRCES CONTROL BOARD THAT WE MUST IMPLEMENT ENHANCED LEAK <br /> DETECTION(ET D)F'OR THE UST(S)COVERED BY IIRS PLAN PER 23 CCR§2644 I,ELD IS PERFORMED EVERY 36 MONIES AS REQUIRED <br /> rtao <br /> REFERENCE DOC(JMEfiTS MAINTAINED AT FACTLIT�'(Check all that apply) <br /> 1 THIS UNDERGROUND STORAGE TANK MONITORING PLAN(Required) <br /> 2 OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENI(Regaired)* <br /> 3 ® THE FACILITY'S BEST MANAGEMENT PRACTICES(.Required as of XNVDD)YY) <br /> 4 ❑ CALIFORNIA UNDERGR.OUND STORAGE TANK REGULATIONS r <br /> 5 ❑ CALIFORNIA UNDERGROUND S IORAGE TANK T,AW <br /> 6 [] STATE WATER RESOURCES CONTROL'BOARD(SWRCB)PUBI KATION: HANDBOOK FOR TANK OWNERS MANUAL AND <br /> STAIISITCA1 INVENTORY RECONCILIATION" <br /> 7. ❑ SWRCB PIJBISCATION:,,WEEKI yMANUAL TANK GAUGING FOR SJ,f L UNDERGROUND STORAGE I ANKS Mat <br /> 99 ❑ OIHER(Specify): _ <br /> Pcgonncl with USI monitoring rrsponstbilities are fhmiliar with all of the above documents relevant to their job duties and can access those documents when needed <br /> By 1/]/2405,this facility will have a"Designated UST Operator who has passed the operator exam administered by the International Code Council XC). By July I, <br /> 2005,and annually thereafter,the `Designated UST Operator'will train facility employees in the proper operation and maintenance ofthe UST systems This training <br /> will include,but is not limited to,the following: <br /> Operation of ffie UST systems in a manner consistent with the facility s best management practices <br /> ''-The facility crnployee's rele with regard to the leak detection equipment _ <br /> A Ihefkcility employee's role with regard to spills and overfills <br /> Whom to contact for emergencies and leak detection alarms <br /> F or facility employees hired on orallorJuly 1,2005,the initial training will be conducted within 30 days of the date of hire — <br /> x _ O N $/AD ITIONAL INFORl'ATI <br /> IO <br /> Please .:use this section to include any additional UST system monitoring-related information(e S,additional information required by your local agency): <br /> e <br /> *Monitoring systems manual maintained by contracted,licensed pump and tank technicians <br /> *Best Management Practices are maintained in the H.S.S,.F.Retail Facility Programs Manual(Green Binder). - <br /> *Tank Overfill Protection Type: Overfill Alarm,Visible and Audible alarm at tank fill point(s)and operates alarm <br /> trigger at 90%. <br /> 'Et9QlrTLP£ NSBI : . ::. <br /> -THE FACLITY OPERATOR DESIGNATED IN SECTION XI BEI OW 1S RESPONSIBLE FOR PEFORMING MONITORING BP lA'ESi COAST PR.ODIICTS <br /> I <br /> IZC I9 RESPONSTT3LE FOR MAINTATNPi 1G AND TESTING ALL MONITORING EQUIPMENT. —_ --. <br /> _'�gi?^ Y �•�{i 5�:?7� 1'1� C7lGitn <br /> CERTIFICATION.I ertify a he_information provided heteln is true and accurate to the best of my knowledge. H91 <br /> 0 IERJOPERAT ATU REPRFSEN IQ DATE: <br /> ❑Owner wo /f <br /> ®Operator _ <br /> hf42- Y193 <br /> O`iJNERK]PERAT RNAME(pnn OWNER/OPERATOR,TIrLi.- <br /> PROMOD K TREHALA FRANCHISEE <br /> (49---y Use Only) This plan has been reviewed and: .Approved ❑A?paved With Conditions ❑Disapproved <br /> Date: <br /> Local Agency Sigasttire _� � —--— —•—�' — — <br /> Comments/Special Conditions -- <br /> f <br /> Page 2 of 5 <br /> Arco02M,Selshife Envtfonnantal Servics <br />
The URL can be used to link to this page
Your browser does not support the video tag.