My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2006 - 2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
800
>
2300 - Underground Storage Tank Program
>
PR0231349
>
COMPLIANCE INFO 2006 - 2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/21/2021 4:57:32 PM
Creation date
11/5/2018 3:55:32 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006 - 2007
RECORD_ID
PR0231349
PE
2351
FACILITY_ID
FA0003633
FACILITY_NAME
ARCO 07049
STREET_NUMBER
800
Direction
E
STREET_NAME
KETTLEMAN
STREET_TYPE
Ln
City
Lodi
Zip
95240
APN
06206042
CURRENT_STATUS
01
SITE_LOCATION
800 E Kettleman Ln
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\K\KETTLEMAN\800\PR0231349\COMPLIANCE INFO 2006 - 2007.PDF
QuestysFileName
COMPLIANCE INFO 2006 - 2007
QuestysRecordDate
2/16/2018 6:39:17 PM
QuestysRecordID
3798594
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
123
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i • <br /> I <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN—PAGE 1 <br /> Moi <br /> TYPE OF ACTION N 1.NEW PLAN ❑ 2.CHANGE OF INFORMATION f <br /> PLAN TYPE N MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY Moz <br /> (Check one item only) ❑ IHIS PLAN COVERS ONLY THE FOLLOWING USI SYS TEMP: i <br /> r, <br /> ,. <br /> _ <br /> FACILITY ID#(Agency Use Only) r <br /> M03 1 <br /> FACILITY NAME ARCO#02076 <br /> FACILITY SITE ADDRESS #800 E.KETTLEMAN LANE M04 CITY LODI Mos <br /> i <br /> MOW .....:.N I` -VI� PVN IV : t fA? 1rTNC <br /> E <br /> State law requires that testing,preventive maintenance,and calibration of monitoring equipment(e.g,sensors,probes,line leak detectors,etc}be performed in 1 <br /> accordance with the equipment manufacturers'instructions,or annually,whichever is more frequent Such work must be performed by qualified personnel (... <br /> Mei " <br /> MONITORING EQUIPMENI IS SERVICED ® 1.ANNUALLY ❑ 99.OTHER(Specify): <br /> . yrs :MO���� � . . e. ......... ................................. ........: � :. <br /> This monitoring plan must include a Site Plan showing the general tank and piping layouts and the locations where monitoring is performed(i e,location of each sensor. <br /> line leak detector,monitoring system control panel,etc) If you already have a diagram(e g.,current UST Monitoring Site Plan from a Monitoring System Certification i <br /> form,Hazardous Materials Business Plan map,etc.)which shows all required information,include it with this plan. � <br /> MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S):(Check all that apply) Mto <br /> ® I CONIINUOUS ELECTRONIC MONITORING OF TANK ANNULAR(INIERSTITIAL)SPACE(S)OR SECONDARY CONTAINMENT VAUL I(S) <br /> SECONDARY CONIAINMENT IS: ® a DRY ❑ b LIQUID FILLED ❑ c UNDER PRESSURE ❑ d UNDER VACUUM Mt t <br /> PANEL MANUFACTURER: Veeder Root M12 MODEL#: TLS 350 M17 <br /> _ LEAK SENSOR MANUFACTURER: _feeder Root Mla MODEL#(S): 794-390-407 Mts. <br /> ❑ 2 AUTOivIAITC TANK GAUGING(ATG)SYSTEM USED TO MONTT OR SINGLE WALL TANK(S}. Ml <br /> PANEL MANUFACTURER: ants MODEL:#: <br /> IN-IANK PROBE MANUFACTURER: Mis MODEL#(S): M19 <br /> LEAK IEST FREQUENCY: Ela CONTINUOUS Elb DAILY/NIGHILY Elc WEEKLY "r20 <br /> Eld MONIHLY [I <br /> (Specify): <br /> e OIHERMel _ <br /> PROGRAMMED TEST'S: ❑ a 0 1 g p h Elb 0 2 g p h ❑ c OTHER(Specify): M21 M27 <br /> ❑ 3 INVENTORY RECONCILIATION ❑ a MANUAL PER 23 CCR§2646 ❑ b STATISTICAL PER 23 CCR§26461 <br /> M24 -- <br /> ❑ 4 WEEKLY MANUAL TANK GAUGING(MIG)PER 23 CCR.§2645 _ <br /> TESTING PERIOD: F1 36 HOURS [Ib 60 HOURS M2s <br /> ❑ 5 INIEGRITY IESTING PER 23 CCR§2643 1 <br /> IEST FREQUENCY: ❑ a ANNUALLY ❑ b BIENNIALLY ❑ c OIHER(Specify): M26 Mer <br /> ❑ 6 VISUAL MONIIORING DONE: ❑ a DAILY ❑ b WEEKLY(Requires agency approval <br /> M28 <br /> ❑ 99.0IHER(Specify): <br /> :....:.':.: €.V.. PIPE:M4NITD�IN.G <br /> N130MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S)(Check all that apply) <br /> ® 1 CONIINUOUS ELECTRONIC MONIIORING OF PIPING SUMP(S)ITRENCH(ES)AND OTHER SECONDARY CONTAINMENT = - <br /> SECONDARY CONIAINMENT IS: N a DRY ❑ b LIQUID FILLED ❑ c UNDER PRESSURE ❑ d UNDER VACUUM Mal <br /> PANEL MANUFACTURER: Veeder Root M32 MODEL#: ILS 350 M33 <br /> M34 S <br /> MODEL# 794-380-323 MIs. <br /> LEAK SENSOR MANUFACIURER: Veeder Root ( ) <br /> WILL A PIPING LEAK ALARM IRIGGER AUTOMATIC PUMP(i e,TURBINE)SHUTDOWN? N a YES El b NO M36. <br /> WILL FAILURE/DISCONNECIION OF IHE MONITORING SYSIEM IRIGGER AUT'OMAIIC PUMP SHUIDOWN? N a YES ❑ b NO M37 <br /> ❑ 2 MECHANICAL LINE LEAK DEIECTOR (MLLD) THAI ROUIINELY PERFORMS 30 g p h LEAK TESTS AND RES'IRICIS OR SHUTS OFF — <br /> PRODUCT FLOW WHEN A LEAK IS DETECTED M39 <br /> MLLDMANUFACIURER(s): M's MODEL#(S): <br /> ® 3 ELECTRONIC LINE LEAK DETECTOR(ELLD)IHAI ROUTINELY PERFORMS 3 0 g p h LEAK IESIS <br /> ELL.D MANUFACIURER: VEEDER ROOT <br /> M40 MODEL#: PLLD Mol <br /> h b.MINIMUM ANNUAL 0 Z h M42 <br /> PROGRAMMED LINE INTEGRITY TESTS: ❑ a MINIMUM MONIHLY 0 2 g p ❑ g P <br /> M47 <br /> WIT. EL.LD DETECTION OF A PIPING LEAK TRIGGER PUMP SHUTDOWN? N a YES El NO <br /> L <br /> WRLEILDFAILURE/DISCONNECIIONTRIGGER AUTOMATIC PUMP SHUTDOWN? N a YES El SHUTDOWN? M44 <br /> ❑ 4.INTEGRIIYIESIING Mas M46 <br /> IESI FREQUENCY: ❑ a.ANNUALLY ❑ b EVERY 3 YEARS ❑ c.01 HER(Specify) <br /> ❑ 5 VISUAL MONITORING DONE ❑ a DAILY ❑ b.WEEKLY* ❑ C.MIN.MONTHLY&EACH TIIviE SYSTEM OPERATED** M47. <br /> 'Requires agency approval «4 Allowed for monitoring ofunburled emergency generator fuel piping only per HSC§25281 5(b)(3) <br /> ❑ 6.PIPING IS SUCTION PIPING MEETING ALL REQUIREMENTS FOR EXEMPTION FROM MONITORING PER 23 CCR§2636(a)(3) <br /> ❑ 7 NO PRODUCI OR REfOI$F PIPING IS CONNECTED T'0 THE USI(:) <br /> ❑ 99.OTHER(Specify) <br /> pI TIM`� Mas <br /> Page 4 of 5 <br /> Arco#02076,Belshire Environmental Services <br />
The URL can be used to link to this page
Your browser does not support the video tag.