My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2006 - 2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
800
>
2300 - Underground Storage Tank Program
>
PR0231349
>
COMPLIANCE INFO 2006 - 2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/21/2021 4:57:32 PM
Creation date
11/5/2018 3:55:32 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006 - 2007
RECORD_ID
PR0231349
PE
2351
FACILITY_ID
FA0003633
FACILITY_NAME
ARCO 07049
STREET_NUMBER
800
Direction
E
STREET_NAME
KETTLEMAN
STREET_TYPE
Ln
City
Lodi
Zip
95240
APN
06206042
CURRENT_STATUS
01
SITE_LOCATION
800 E Kettleman Ln
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\K\KETTLEMAN\800\PR0231349\COMPLIANCE INFO 2006 - 2007.PDF
QuestysFileName
COMPLIANCE INFO 2006 - 2007
QuestysRecordDate
2/16/2018 6:39:17 PM
QuestysRecordID
3798594
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
123
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN-PAGE 2 <br /> 1tfSSIS <br /> 4150 <br /> MONITORING OF AREAS BENEATH DISPENSER(S)IN-PE"uxmw USING THE FOLLOWING METHOD(S)(Check all that apply) <br /> 1-CONTINUOUS ELECTRONIC MONITORING OF UNDER DISPENSER CONIAINMENT(UDC) M52 <br /> PANEL MANUFACTURER: Veeder Root M5' MODEL 9: TLS350 U54 <br /> M'3 MODEL#(S): 794-389-323 <br /> LEAK SENSOR MANUFACTURER: Veeder Root M55 <br /> WILI.DEJECITON OF A LEAK INTO T 0 a YES [I b NO HE UDC TRIGGER AUDIBLE AND VISUAL ALARMS? M56 <br /> WILL A UDCLEAKAILARM MGGERAUTOMAIIC PUMP SHUTDOWN? ® a.YES El b NO <br /> OWN? Z a YES [I b NO M" <br /> WILI.FAILURE/DISCONNECTION OF UDC MONITORING SYSTEM TRIGGER AUTOMATIC PUMP SHUID <br /> ❑ 2 MECHANICAL ASSEMBLY(e g,FLOAT AND CHAIN ASSEMBLY)IN UDC TRIPS SHEAR VALVE IN CASE OF LEAK <br /> M59 t <br /> ASSEMBLY MANUFACTURER: "Is MODEL#(S). <br /> M60 <br /> rl 3 VISUAL MONT rORING DONE: F1 a DAILY El b WEEKLY(Requires agency approval) <br /> E] 4 NO DISPENSERS M61 <br /> F1 99.OTHER(Specify) <br /> I It,N7.. <br /> A: <br /> D <br /> M70 <br /> 11 <br /> WE HAVE BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL BOARD THAT WE MUST IMPLEMENT ENHANCED IEA:K <br /> H EQ <br /> DETECTION ELD)FOR THE USI(S)COVERED BY THIS PLAN PER 23 CCR§2644 1,ELD IS PERFORMED EVERY 36 MONTHS AS REQUIRED <br /> ................... <br /> M80 <br /> REFERENCE DOCUMENTS MAINTAINED AT FACILITY(Check all that apply) <br /> I THIS UNDERGROUND STORAGE TANK MONITORING PLAN(Required) <br /> 2 OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT(Required)* <br /> 3 THE FACIIITY'S BEST MANAGEMENT PRACTICES(Required as of MM/DD/YY) <br /> 4 F1 CALIFORNIA UNDERGROUND STORAGEIANK REGULATIONS <br /> 5 Fj CALIFORNIA UNDERGROUND STORAGE TANK LAW TANK OWNERS MANUAL AND <br /> 6 F1 STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "HANDBOOK FOR <br /> STATISTICAL INVENTORY RECONCILIATION" <br /> 7. El SWRCB PUBLICATION:"WEEKLY MANUAL TANK GAUGING FOR SMALL UNDERGROUND STORAGE TANKS'' .Mol <br /> 99.[] OTHER(Specify): <br /> Personnel with UST monitoring responsibilities are familiar with all of above documents relevant to their job duties and can access those documents when needed <br /> By I/1/2005,this facility will have a'Designated UST Operator' who has passed the operator exam administered by the International Code Council(ICC). By July 1, <br /> 2005,and annually thereafter,the "Designated UST Operator"will train facility employees in the proper operation and maintenance of the UST systems This training <br /> will include,but is not limited to,the following: <br /> > Operation of the UST systems in a manner consistent with the facility s best management practices 7 <br /> > The facility employee's role with regard to the leak detection equipment <br /> > The facility employee's role with regard to spills and overfills <br /> > Whom to contact for emergencies and leak detection alarms <br /> For facility employees hired on or after July 1,2005,the initial training will be conducted within 30 days of t.he date of hire. <br /> ......... ION <br /> INFO <br /> M85 <br /> d information(e g,additional information required by your local agency): <br /> Please use this section to include any additional UST system monitoring-relate <br /> *Monitoring systems manual maintained by contracted,licensed pump and tank technicians. <br /> Best Management Practices are maintained in the H,,&S.EL,Retail Facility Programs Manual(Green Binder). <br /> ". 0 L $..-.ON L <br /> ... .... ... ...... <br /> F <br /> ....... <br /> THE FACILITY OPERATOR DESIGNATED IN SECTION XI BELOW IS RESPONSIBLE FOR FEkURMING MONITORING. BP WEST COAST PRODUCTS <br /> LLC IS RESPONSIBLE FOR MAINTAINING AND TESTING ALL MONITORING EQUIPMENT, <br /> ............ <br /> SIGN A U <br /> MMR/Olp _T <br /> tATOR: <br /> CERTIFICATION: ertify a e jnfDr'M1tiD13 provided her ein is true and accurate to the best of my knowledge.'t <br /> 0 ER/OPE <br /> E REPRESENTING DATE: <br /> OWNER/OPERAT ATU D owner m90 <br /> Ej Operator M93 <br /> T E(P�� OWNER/OPEM92 TOR ILE: <br /> OWNER/OPERATORN�A�(pun M <br /> U nM0 T FRANCHISEE <br /> PIRROMOD K TREHAN <br /> (Agency use only) This plan has been reviewed and: El Approved ❑Approved With Conditions [I Disapproved <br /> Local Agency Signature: pate: <br /> Comments/Special Conditions: <br /> Page 2 of 5 <br /> Arco#02076,Belshire Environmental Services <br />
The URL can be used to link to this page