My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2006 - 2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
800
>
2300 - Underground Storage Tank Program
>
PR0231349
>
COMPLIANCE INFO 2006 - 2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/21/2021 4:57:32 PM
Creation date
11/5/2018 3:55:32 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006 - 2007
RECORD_ID
PR0231349
PE
2351
FACILITY_ID
FA0003633
FACILITY_NAME
ARCO 07049
STREET_NUMBER
800
Direction
E
STREET_NAME
KETTLEMAN
STREET_TYPE
Ln
City
Lodi
Zip
95240
APN
06206042
CURRENT_STATUS
01
SITE_LOCATION
800 E Kettleman Ln
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\K\KETTLEMAN\800\PR0231349\COMPLIANCE INFO 2006 - 2007.PDF
QuestysFileName
COMPLIANCE INFO 2006 - 2007
QuestysRecordDate
2/16/2018 6:39:17 PM
QuestysRecordID
3798594
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
123
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
7. PIPING SUMP TESTING <br /> T.st Method Developed By: ❑ Sump Manufacturer N Industry Standard ❑ Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: F-1Pressure [I Vacuum ®Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: Incon Sump Tester Equipment Resolution: +/-0.002" <br /> STP Sump 487-2 STP Sump#87-1 STP Sump#87-3 STP Sump#91 <br /> Sump Diameter: 48" 48" 48" 48" <br /> Sump Depth: 53" 52" 52" 52" <br /> Sump Material: Fiberglass Fiberglass Fiberglass Fiberglass <br /> Height from Tank Top to Top of 42„ 35" 32" 21" <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 28„ 27" 28" 28" <br /> Electrical Penetration: <br /> Condition of sump prior to testing: Good Good Good Good <br /> Portion of Sump Tested' 2"above piping 2"above piping 2" above piping 2"above piping <br /> Does turbine shut down when <br /> sump sensor detects liquid(both ❑Yes ❑No N NA ❑Yes ❑No NNA ❑Yes ❑No ENA ❑Yes❑No N NA <br /> product and water)?4 <br /> Turbine shutdown response time N/A N/A N/A N/A <br /> Is system programmed for fail-safe ❑yes❑No N NA ❑ Yes❑No NNA ❑ Yes❑No NNA ❑Yes❑No N NA <br /> shutdown?' <br /> Was fail-safe verified to be ❑yes ❑No N NA ❑Yes❑No ENA ❑ Yes ❑No NNA ❑ Yes ❑No N NA <br /> operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and starting 30 minutes 30 minutes 30 minutes 30 minutes <br /> test: <br /> Test Start Time: 12:47pm 1:06pm 12:47pm 1:06pm 12:47pm 1:06pm 12:47pm 1:06pm <br /> Initial Reading(RI): 1.4633 1.4629 4.1780 4.1778 2.9812 2.9813 3.4684 3.4677 <br /> Test End Time: 1:02pm 1:22pm 1:02pm 1:22pm 1:02pm 1:21pm 1:02pm 1:21pm <br /> Final Reading(RF): 1.4631 1.4627 4.1779 4.1778 2.9813 2.9813 3.4682 3.4674 <br /> Test Duration: 15 min. 16 min. 15 min. 16 min. 15 min. 15 min. 15 min. 15 min. <br /> Change in Reading(RF-RI): -.0002 -.0002 -.0001 none +.0001 none -.0002 -.0003 <br /> Pass/Fail Threshold or Criteria: +/-0.002" +/-0.002" +/-0.002" +/-0.002" <br /> Test Result: X Pass ❑Fail X Pass ❑Fail X Pass ❑Fail X Pass ❑Fail <br /> Was sensor removed for testing? N Yes ❑No ❑NA N Yes ❑No ❑NA N Yes ❑No ❑NA N Yes ❑No ❑NA <br /> Was sensor properly replaced and ®yes El No El NA N Yes El <br /> ❑NA N Yes ❑No ❑NA ® Yes❑No ❑NA <br /> verified functional after testing? <br /> Comments— (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> "Sensor functionality was not confirmed. This procedure is not part of the <br /> Secondary Containment testing scope of work". <br /> 'If the entire depth of the sump is not tested,specify how much was tested. If the answer to Any of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) ( T >j <br />