My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2006 - 2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
800
>
2300 - Underground Storage Tank Program
>
PR0231349
>
COMPLIANCE INFO 2006 - 2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/21/2021 4:57:32 PM
Creation date
11/5/2018 3:55:32 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006 - 2007
RECORD_ID
PR0231349
PE
2351
FACILITY_ID
FA0003633
FACILITY_NAME
ARCO 07049
STREET_NUMBER
800
Direction
E
STREET_NAME
KETTLEMAN
STREET_TYPE
Ln
City
Lodi
Zip
95240
APN
06206042
CURRENT_STATUS
01
SITE_LOCATION
800 E Kettleman Ln
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\K\KETTLEMAN\800\PR0231349\COMPLIANCE INFO 2006 - 2007.PDF
QuestysFileName
COMPLIANCE INFO 2006 - 2007
QuestysRecordDate
2/16/2018 6:39:17 PM
QuestysRecordID
3798594
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
123
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r , i.avi a a Vahai ,V l) l /J 1 JJlTi \.2-J1.Ll it A%-,, X aiVl <br /> For By All Jurisdictions Within the State of California <br /> Authority Cited:Chapter 6.7, Head Safety Code;Chapter 16, Division 3 Title 23, Cal Code of Regulations <br /> s form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility,a separate <br /> rtification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br /> >tem owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> General Information <br /> icility Name: ARCO 02076, CC 18022641 City: LODI CA Zip: 95240 <br /> to Address: 800 KETTLEMAN LN Contact Phone No: 334-3678 <br /> PTO N-85 Date of Testing/Service: 05/02/2007 <br /> icility Contact Person: MANGER <br /> ake/Model of Monitoring System:TLS-350 Work Order Number: 2248888 <br /> Inventory of Equipment Tested/Certified <br /> Teck the appropriate boxes to indicate specific equipment inspected/serviced <br /> Tank ID: 91 Tank ID: 87 MASTER <br /> X In-Tank Gauging Probe. Model: MAG Q In-Tank Gauging Probe. Model: MAG <br /> X Annular Space or Vault Sensor. Model: 407 X Annular Space or Vault Sensor. Model: 407 <br /> X Piping Sump/Trench Sensor(s). Model: 323 ❑X piping Sump/Trench Sensor(s). Model: 323 <br /> X Fill Sump Sensor(s). Model: 323 <br /> Fill Sump Sensor(s). Model: 323 <br /> Mechanical Line Leak Detector. Model: ❑ <br /> Mechanical Line Leak Detector. Model: <br /> X Electronic Line Leak Detector. Model: ELECT. X <br /> ❑ Electronic Line Leak Detector. Model: ELECT. <br /> X Tank Overfill/High-Level Sensor. Model: MAG ® Tank Overfill/High-Level Sensor. Model: MAG <br /> Other(specify equipment type and model in Section E on page 2). ❑ Other(specify equipment type and model in Section E on page 2). <br /> Tank ID: 87 SLAVE TanklD: <br /> In-Tank Gauging Probe. Model: MAG In-Tank Gauging Probe. Model: MAG <br /> X Annular Space or Vault Sensor. Model: 407 Annular Space or Vault Sensor. Model: 407 <br /> X Piping Sump/Trench Sensor(s). Model: 323 X Piping Sump/Trench Sensor(s). Model: 323 <br /> _X1 Fill Sump Sensor(s). Model: 323 ❑X Fill Sump Sensor(s). Model: 323 <br /> Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: MAG ® Tank Overfill/High-Level Sensor. Model: MAG <br /> Other(specify equipment type and model in Section E on page 2). ❑ Other(specify fyequipment type and model in Section E onpage 2). <br /> Ispenser : 1-2 Dispenser ID: 3-4 <br /> 0 Dispenser Containment Sensor(s) Model:323 X Dispenser Containment Sensor(s) Model:323 <br /> X❑Shear Valve(s). X] Shear Valve(s) <br /> ❑Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5-6 Dispenser ID: 7-8 <br /> 0 Dispenser Containment Sensor(s) Model:323 . Dispenser Containment Sensor(s). Model:323 <br /> X❑ Shear Valve(s). Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑ Dispenser Containment Sensor(s) Model: ❑ Dispenser Containment Sensor(s). Model: <br /> ❑ Shear Valve(s). Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> Certification <br /> I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this certification is information(e.g manufacturers'checklists)necessary to verify that this information is correct. <br /> and a Site Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports, I have also attached <br /> a copy of the(Check all that apply): System set-up X❑Alarm history report <br /> e .�, a <br /> chnician Name(print): DENNIS RUE Signature: <br /> !rtification No.: 006-05-1510 License. No.: <br /> sting Company Name:Tanknology Phone No.: (800)800-4633 <br /> e Address: 8501 N. MoPac Expressway,suite 400,Austin,TX 78759 Date of Testing/Servicing: 05/02/2007 <br /> Pana 1 of.1 acarl nn('A fnrm riatarl wvn1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.