Laserfiche WebLink
AML <br /> San Joaquin County 40 <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone. (209)468-3420 Fax:(209) 468-3433 Web:www.siaov.ora/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> LATHROP GAS & FOOD INC 140 E LATHROP RD, LATHROP December 12, 2016 <br /> UST System Observations <br /> 322 HSC 25281.6(a) Unburied below grade emergency generator system failed to meet exemption status �V �R ❑COS <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status ❑V ❑R ❑COS <br /> 324 CCR 2717.1(g) Tampered with red tag ❑V ❑R ❑COS <br /> 325 CCR 2717.1(f) Deposited petroleum into a red tagged UST ❑V o R ❑COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms o V a R ❑COS <br /> 327 CCR 2631.1 UST system not compatible with the substance stored ❑V ❑R ❑COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements ❑V ❑R ❑COS <br /> 329 HSC 25298 Failed to comply with permanent closure requirements ❑V ❑R ❑COS <br /> 330 CCR 2636(f)(6) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system r V r.R n COS <br /> Single-Walled Non-Pressurized Piping <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve ❑V ❑R ❑COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed ❑V ❑R ❑COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) ❑V L R ❑COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed (pre-January 1984) ❑V c R ❑COS <br /> Other Violations <br /> 2010 See below Unlisted Administration/Documentation violation ❑V i-R r.COS <br /> 2030 See below Unlisted Operations/Maintenance violation it V R L. COS <br /> 2060 See below Unlisted Design/Construction violation n V R COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS 1,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 103 HSC 25292.2 Current financial responsibility documents not submitted. <br /> Financial responsibility documents have not been submitted to the EHD. Current financial responsibility documents <br /> are required to be submitted annually. Immediately log into the California Environmental Reporting System (CERS) <br /> v at http://cers.calepa.ca.gov/, and upload the required documents. <br /> This is a minor violation. <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br /> UST Facility Operating Permit Application and UST Tank Information for TA0505688, TA0505689, and TA0505690 <br /> are not current in California Environmental Reporting Syste (CERS. The Board of Equalization number, 44048818, <br /> is closed and not valid. The UST Tank Information for all three tanks needs the following revisions: beneath Vent, <br /> Vapor Recovery (VR)and Riser/Fill Pipe Piping Construction, enter the Vent Primary Containment; beneath Under <br /> Dispenser Containment(UDC) change"double-walled"to"single-walled'; and beneath Corrosion Protection, <br /> change"No"to"Yes"for Isolation. Any change of information must be updated in CERS within 30 days of the <br /> changes. Immediately log into CERS, update the required information, and submit for review by the Environmental <br /> Health Department(EHD). <br /> This is a repeat violation, Class II. <br /> FA0006943 PRO505687 SC001 12/12/2016 <br /> EHD 23-01 Rev.09/22/16 Page 3 of 5 Underground Storage Tank Program OIR <br />