My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
140
>
2300 - Underground Storage Tank Program
>
PR0505687
>
COMPLIANCE INFO_2016-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2022 1:48:32 PM
Creation date
11/5/2018 4:42:33 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016-2018
RECORD_ID
PR0505687
PE
2361
FACILITY_ID
FA0006943
FACILITY_NAME
LATHROP GAS & FOOD INC
STREET_NUMBER
140
Direction
E
STREET_NAME
LATHROP
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
19611007
CURRENT_STATUS
01
SITE_LOCATION
140 E LATHROP RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LATHROP\140\PR0505687\COMPLIANCE INFO.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
112
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax: (209)468-3433 Web:www.sigov.org/eh <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> LATHROP GAS & FOOD INC 140 E LATHROP RD, LATHROP December 12, 2016 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 105 CCR 2632(d)(1) Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the Environmental Health Department(EHD). The <br /> monitoring plan for all three tanks have the following issues: <br /> -Beneath Tank Monitoring is Performed Using the Following Method(s)enter"Dry"for Secondary Containment <br /> System. <br /> -Beneath Pipe Monitoring is Performed Using the Following Method(s), enter"Dry'for Piping Secondary <br /> Containment. <br /> -Beneath Under Dispenser Containment(UDC) Monitoring remove"Veeder Root'from UDC Panel Manufacturer; <br /> remove"TSL-350 from UDC Panel Model#; removed"Bravo" from UDC Leak Sensor Manufacturer; remove <br /> "FLOAT& CHAIIJ'from UDC Leak Sensor Model; and change"Yes"to"No"for Failure/Disconnection of UDC <br /> Monitoring System Triggers Automatic Pump Shutdown; and <br /> - Beneath Record Keeping, change"No" to"Yes"for Equipment Maintenance and Calibration Records. <br /> The monitoring plan must be uploaded to California Environmental Reporting System(CERS). Immediately log into <br /> CERS, make the necessary changes, and submit for review by the EHD. Make sure that a copy is available for <br /> inspection at any time. <br /> This is a repeat violation, Class II. <br /> 106 "Thisisam <br /> )(2) Failed to have an approved UST response plan. <br /> se Plan is not current and/or approved by the Environmental Health Department(EHD). Section V of <br /> se Plan has not been completed. The Response Plan must be uploaded to the California <br /> tal Reporting System (CERS). Immediately log into CERS, upload the completed form, and submit for <br /> e EHD. Ensure that a copy is available for inspection at any time. <br /> peat violation, Class IL <br /> 308 CCR 2636(f) Failed to maintain a continuous monitoring system that activates an audible and visual alarm. <br /> The 87-product 208 sensor in the submersible turbine pump sump had a broken wire and could not be tested to <br /> ensure continuous monitoring of the tank system. Ail monitoring equipment shall be maintained to activate an <br /> audible and visual alarm or stop the flow of product at the dispenser when it detects a leak. The sensor was <br /> replaced and retested during the inspection. A"UST Retrofit Verification with Inspector Already Onsite"form has <br /> been completed and provided to the operator and contractor. <br /> This was corrected on site. <br /> This is a minor violation. <br /> 310 CCR 2636(f)(5) Piping is not fail-safe outside UDCs or fails to stop flow of product at dispenser inside UDCs. <br /> The Bravo box floats and chains in the under dispenser containment(UDC) 5/6 (91-product)and 11/12 (87-, 91-, <br /> and diesel-product)failed to stop the flow of product at the dispenser when tested. All monitoring equipment shall <br /> be maintained to activate an audible and visual alarm or stop the flow of product at the dispenser when it detects a <br /> leak. The service technician adjusted the floats and chains and verified functionality. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> FA0006943 PRO505687 SC001 12/12/2016 <br /> Pa e 4 of 5 Underground Storage Tank Program OIR <br /> EHD 23-01 Rev.09/22/16 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.