COMPLIANCE INFO 2013-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
192
>
2300 - Underground Storage Tank Program
>
PR0505867
>
COMPLIANCE INFO 2013-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:19 PM
Creation date
11/5/2018 4:46:06 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2015
RECORD_ID
PR0505867
PE
2361
FACILITY_ID
FA0007059
STREET_NUMBER
192
STREET_NAME
LATHROP
STREET_TYPE
Rd
City
Lathrop
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
192 Lathrop Rd
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LATHROP\192\PR0505867\COMPLIANCE INFO 2013-2015.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
210
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r 10 <br />SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.$4gov.org/ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />Facility Tower Mart #404 Facility <br />Name: Address: 192 Lathrop Road, Lathrop Inspection Jan 16 2013 <br />Date: , <br /># <br />204 <br />205 <br />206 <br />207 <br />Cl I C2 M I Code Section <br />GCR 2715(c) <br />CCR 2715(e) <br />CCR 2715(f) <br />HSG 25281.5(b)(2) <br />HSG = GA Health and Safely Code; CFR = Code of Federal Regulations <br />C1 = Class 1 violation; C2 = Class 2 violation, M = Minor violation <br />On Site Records (continue <br />Designated operator monthly spection (1 larms not documented; (2-4) spill containers, UDCs, and sumps <br />if necessary) not inspected 5 required t dates not checked or noted; 6 employee training not verified <br />Designated operator monthl spection reports not maintained on site for at least 12 months <br />Designated operator employee training: (1) not performed; (2) not current for at least one employee on site: <br />3 to not kept <br />Unburied fuel piping at marinas not visually inspected at least daily or log not kept <br />Observations <br />301 <br />HSG 25292.1 <br />UST system is not operated to prevent unauthorized release, including spills and overfills <br />302 <br />HSC 25291(b) <br />UST monitoring system incapable of detecting leak from primary containment into secondary -containment (Ml) <br />303 <br />CCR 2630(d) <br />UST monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity (Mi) <br />304 <br />CCR 2632(c)(2) <br />Monitoring system is not present in the interstitial space of a double walled UST (M 1) <br />305 <br />CCR 2636(f)(1) <br />Failed to maintain a continuous monitoring system for underground piping & UDCs that activates an (Mi) <br />402 <br />HSC 25283.51 <br />audible and visual alarm or stops flow of product at the dispenser when it detects a leak <br />306 <br />CCR 2631(a) <br />Primary containment is not product tight <br />307 <br />HSC 25291(a)(2) <br />Secondary containment for UST system is not tight <br />308 <br />GCR 2636(c)(1) <br />All releases in secondary piping do not flow to a collection sump <br />309 <br />CCR 2636(a) <br />Failed to have secondary containment for piping (includes conventional suction piping) (M2y <br />310 <br />HSC 25291(e) <br />Water in 21 containment not removed, analyzed & properly disposed of <br />311 <br />CCR 2636(%2) <br />Line leak detector(s) not installed or failed to detect a 3 -gallon per hour leak at 10 psi (Mi) <br />312 <br />CCR 2635(b) <br />No spill container or overfill prevention system installed (M2) <br />313 <br />CCR 2635(b)(1) <br />Spill container failed to contain a minimum capacity of five gallons, or failed to provide a means to keep (M2) <br />HSC 25290.2(d) <br />the spill container empty <br />314 <br />CCR 2635(b)(2) <br />Overfill prevention system was overridden or failed to meet overfill requirements (M2l <br />315 <br />HSC 25299(f)(2) <br />Tampering with or disabling leak detection devices or alarms <br />316 <br />CCR 2631.1(a) <br />UST system is not compatible with the substance stored <br />317 <br />HSC 25298(x) <br />Illegally abandoned UST system <br />407 <br />AB 1702 (2003-2004) HSC 25290.1 (installed between 07!01103 and 06/30/04) <br />%mw C.,r F.. m.. !JCI^ ncnnn A /:.....L...1 L.J <br />Emergency Generator Systems <br />501 <br />CCR 2636(f)(6) <br />Compatibility and permeability requirements: (a) UST system is not compatible with the substance stored; (b) <br />401 <br />CCR 2631.1 <br />results of the compatibility and permeability testing requirements listed in subsections CCR 2631(b) and (d} <br />USTs in a Vault <br />601 <br />HSC 25283.5(a)(1) <br />for a UST system installed after Jul 1, 2004, were not submitted <br />402 <br />HSC 25283.51 <br />Structure that the UST is located in does not provide for secondary containment <br />603HSC <br />HSC 25290.1(c)(1) HSC 25290.2(c)(1) <br />Primary containment not liquid or vapor tight <br />403 <br />HSC 25283.5(a)(5) <br />UST installed after July 1, 2003, does not meet or exceed applicable sections of HSC 25291 <br />HSC 25290.1(c)(2) <br />HSC 25290.2 c 2 <br />Secondary containment not liquid or vapor tight <br />404 <br />CCR 2643(d) <br />Daily monitoring of suction piping (pre -January 1, 1984) not performed (M1) <br />Inspector. <br />Thuy Tran <br />HSC 25290.1(c)(3) <br />HSC 25290.2(c)(3) <br />Secondary containment not constructed to prevent water intrusion <br />405 <br />EHD 23-02 Rev 04/19/12 <br />- - <br />Page 2 UST INSPECTION REPORT <br />HSC 25290.1(d) <br />Monitoring system not maintained to detect water intrusion into the secondary containment, or the entry of <br />HSC 25290.2(d) <br />liquid orVapor from the primary containment into the seconds containment <br />406 <br />HSC 25290.1(e) <br />Interstitial liquid measurement method, constant vacuum, or constant pressure in the interstitial space of the <br />UST system not maintained <br />407 <br />HSC 25290.10) <br />"r <br />UST system not tested by one of the following methods prior to use: (1) Enhanced leak detection; (2) inert gas <br />HSC 25290.2 <br />pressure test approved by SWRCB; (3) test method deemed Pni tivarant to !11 nr ON i ft,A ctnrprR <br />Emergency Generator Systems <br />501 <br />CCR 2636(f)(6) <br />Emergency generator monitoring system not checked daily or lag not kept if no leak detector (M1) <br />502 <br />HSC 25281.5(b)(3) <br />Unburied fuel piping not visually inspected at least monthly or log not kept {M1) <br />USTs in a Vault <br />601 <br />HSC 25283.5(a)(1) <br />All exterior surfaces of the tank and connected piping cannot be directly viewed <br />602 <br />HSC 25283.51 <br />Structure that the UST is located in does not provide for secondary containment <br />603HSC <br />25283.51 <br />Failed to conduct weekly UST inspections or maintain a log of weekly inspections <br />604 <br />HSC 25283.5(a)(5) <br />UST installed after July 1, 2003, does not meet or exceed applicable sections of HSC 25291 <br />Non -Pressurized Piping <br />701 <br />CCR 2643(d) <br />Daily monitoring of suction piping (pre -January 1, 1984) not performed (M1) <br />Inspector. <br />Thuy Tran <br />(209) 468-8257 <br />Recei Title: <br />A --L <br />� 6 <br />EHD 23-02 Rev 04/19/12 <br />- - <br />Page 2 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.