My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
192
>
2300 - Underground Storage Tank Program
>
PR0505867
>
COMPLIANCE INFO 2013-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:19 PM
Creation date
11/5/2018 4:46:06 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2015
RECORD_ID
PR0505867
PE
2361
FACILITY_ID
FA0007059
STREET_NUMBER
192
STREET_NAME
LATHROP
STREET_TYPE
Rd
City
Lathrop
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
192 Lathrop Rd
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LATHROP\192\PR0505867\COMPLIANCE INFO 2013-2015.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
210
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 0 <br />SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.ora/ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />FacilityTower Mart #104 Fa <br />Name: Date: <br />192 Lathrop Road, Lathrop Inspection <br />Hams:: AdJan 16 2013 <br />VIOLATIONS <br />C1 C2 M Code Section HSC = CA Health and Safety Code; CFR = Code of Federal Regulations <br />Ci =Class 1 violation; C2 =Class 2 violation; M = Minor violation <br />Non -Pressurized Piping (continued) <br />702 CCR 2643(e) Biennial tightness test of gravity piping not performed (pre -January 1, 1984) IMI? <br />743 L ICCR 2643(d) Triennial line test for conventional suction piping not performed (pre -January 1, 1984) (MI) <br />Other Violations <br />999 Other: See attached "Continuation — Official Inspection Report" for violation(s) not listed above. <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR -Notice to Cornpl <br />UST Inspection- Routine & Annual Monitoring System Certification <br />310. Approximately 112 to 1 gallon of liquid was found in 87 Master Fill sump, Diesel Fill sump and 3 <br />cups of liquid in Diesel STP sump seen during annual compliance testing today. In addition, from the <br />Walton Engineering work orders, it appears that the L16 diesel fill sump liquid detection sensor is in <br />alarm often - <br />1. WO # 49352, on 05102112, approximately 3 gallons of liquid was removed <br />2_ WO # 48725, on 04108112, liquid was removed <br />3. WO # 48094, on 03120112, diesel fill sump alarm <br />4. WO # 39975, on 06/08/11, approximately 4 gallons liquid removed form 87 fill & diesel fill sump <br />If water could enter into the secondary containment by precipitation or infiltration, it must be removed <br />and disposed of properly. Immediately remove this liquid, make a hazardous waste determination per <br />Title 22 hazardous waste regulations, and manage it accordingly. Ensure that the Fill sumps and all <br />other sumps are maintained free of liquid. <br />- Corrected on site. Technician removed liquid and placed it into facility's hazardous waste drum. <br />Submit a statement explaining how or if any repairs will be made to prevent any future liquid intrusion <br />into any sumps, especially for the diesel fill sump_ <br />204. Designated Operator (DO) failed to document date of alarm. On a DO May 2012 report, he <br />documented a 05/02/12 for L16 Diesel Fill Sump fuel alarm. The L16 alarm occurred on 04/25/12, <br />03/31/12 and 03/16/12, but no alarm on 05/02/12. There was a Walton Engineering work order for <br />05/02/12 in response to the L16 alarm. DO must document alarm date of Occurrence but reference when <br />action response was taken. During the monthly inspection, the designated operator shall review the <br />alarm history for the previous month, check that each alarm was documented and responded to <br />appropriately, and attach a copy of the alarm history with documentation taken in response to any <br />alarms to the monthly report. Ensure that designated operators performing monthly inspections at this <br />facility are including all of the required information on the reports. Submit a statement ensure DO <br />correctly documents date of each alarm occurrence. <br />ALL EHD STAFF TIME ASSOCIATED 141TH FAILING TO COMPLY BY THE ABOVE NOTED DATES MILL BE BILLED AT THE CURRENT HOURLY RATE_ <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT END'S CURRENT HOURLY RATE. <br />-ate �a i uvJr �, ivry rttruN r <br />