SITE PLUMBING ENGINEERING DATA KEYNOTES <br /> o� <br /> DESIGN REQUIREMENTS I I" GW w/ SOV IN BOX w/ LID MARKED "WATER". z E3 <br /> THE FOLLOWING IS FOR COMMERCIAL USE OF BUILDING O / `o � d� <br /> DEMAND - 2210 F.U. / 16.0 GPM. / 3 :x <br /> AMOUNT FXTUR FIXTURE UNIT VALUES REFER TO DETAIL: PI1 z;oE A <br /> COLD WATER WASTE2O4" W WITH 2-WAY CLEANOUT. EXIT INVERT ELEVATION = 80 92W9 <br /> O <br /> F.U. EACH F.U. TOTAL F.U. EACH F.U. TOTAL WITH FINISHED FLOOR AT 4780. DEMAND = 2410 F.U. 1 2 5g�p 0 <br /> 2 WATER CLOSET (F.T.) 2.5 5.0 4.0 8.0 REFER TO DETAIL: PI I P1I `� !m§L" <br /> 2 LAVATORIES 1.0 2.0 1.0 2.0 o cyim <br /> 5 SINK 1.5 7.5 2.0 10.0 m <br /> 1 CLOTHES WASHER 4.0 4.0 3.0 3.0 ®3" W WITH 2-WAY F OOR AT 1 EXIT INVERT ELEVATION = .80 <br /> WITH FINISHED FLOOR AT 4'1.80. DEMAND = 4.0 F.U. 4 <br /> I HOSE BIBBS 2.5 2.5 -- -- REFER TO DETAIL: I 2 z � €+4 <br /> 4 EACH ADDITIONAL HOSE BIBB 1.0 4.0 <br /> Pl.l Pl.l o <br /> 4 FLOOR DRAIN -- -- 2.0 8.0 0_______________________ NOT USED -----------____-__-_______ a B£ <br /> TOTAL UNITS TOTAL 25.0 TOTAL 31.0 /��� <br /> 25.0 TOTAL FIXTURE UNITS EQUALS . . . . . . 18.0 GPM. �B <br /> ®6" FIRE SPRINKLER RISER REFER TO DETAIL: PLI i <br /> 1. PRESSURE AVAILABLE AT STREET MAIN . . 40.00 PSI. O3" R.W.L. DOWN IN WALL FROM ROOF DRAIN. PROVIDE w/ WOO N <br /> 2, PRESSURE LOSS DUE TO HEIGHT 4 Ft. x 0.434 . 1.74 PSI. AND EXTEND OUT 5'-0" FOR CONNECTION BY CIVIL. 5, <br /> 3. PRESSURE LOSS THRU METER 4.00 PSI. <br /> PARCEL "B" 4. PRESSURE LOSS DUE THRU OTHER DEVICES REFER TO DETAIL: PSI <br /> I (i.e. Water Softner, Backflow Preventer) 10.00 PSI. ®4" R.W.L. DOWN IN WALL FROM ROOF DRAIN. PROVIDE w/ WCO- <br /> ! 5. TOTAL PRESSURE LOSS (add lines 2 thru 4) 15.74 PSI. AND EXTEND OUT W-0" FOR CONNECTION BY CIVIL 5 <br /> 6. PRESSURE REQUIRED AT HIGHEST FIXTURE . . . . . 8.00 PSI. REFER TO DETAIL: <br /> 7. PRESSURE AVAILABLE FOR FRICTION LOSS . . . . . 16.26 PSL P8.1 <br /> (Subtract lines 5 & 6 from line 1) . . . . . . . . . . 0 0 <br /> :I 8. TOTAL DEVELOPED LENGTH OF RUN . . . . . . . . . . 200 ft. Uj <br /> V) a <br /> ©3" W WITH 2-WAY CLEANOUT. EXIT INVERT ELEVATION = 4 .'10 <br /> FRICTION LOSS CALCULATION WITH FINISHED FLOOR AT 49]0. DEMAND - 410 F.U. <br /> From line 7 1( 6.26 ) PSI x 100 = 813 / 100 ft. REFER TO DETAIL: 1 J <br /> ` <br /> From <br /> ` DOMESTIC (COLD WATER SIZING CHART DEMAND O 5.0 F.U.IN BO/510 G.PMwl LID ARICED WATER . PLI � 0 � B � <br /> - / REFER TO DETAIL: 3 Z W 8 <br /> P. <br /> ' l �/ ,s P.U. z <br /> PIPE SIZE v 4 a a 8 <br /> z G t as ✓ / / G CJ G/ F.T. F.V. ® NOT USED <br /> D o a n Is d G <br /> - - - I/' 3 -- 9O3 SUMP PUMP DISCHARGE. EXTEND 5 -0' FROM BUILDING � <br /> PARCEL "A" 3/4 10 -- FOR CONNECTION BY OTHERS. <br /> 1" 24 -- I0 GAS LINE TO BE SLEEVED AND VENTED PER CODE. <br /> 9 II/4" 51 12 <br /> 2" 236 116 <br /> I ' I " m ttu <br /> - <br /> 't �I / 21/7 506 396 J � <br /> FI-I FI-1 1-1-1 FINISHED FLOOR 'I' .per i THE 91ZING CHART IS BASEp ON <br /> GENERAL NOTES z � <br /> n ELEVATION = 49 ,„„/- THE 2009 CPG APPENDIX 'A' ,Q <br /> El WITH A AP OF B10 PSI PER 100 FT <br /> - III III n UO w/ MAXIMUM VELOCITY OF Sft/SEC. I.) PLUMBING CONTRACTOR TO COORDINATE ROUTING OF U <br /> LIJ LIJ LIJ u I I <br /> PLUMBING SERVICES w/ MECHANICAL, ELECTRICAL, FIRE "e U } <br /> AND GENERAL CONTRACTOR TO ELIMINATE ANY SPACE _� U <br /> FINISHED FLOOR CONFLICTS. <br /> 1I -- - -- 2 - •;- � ELEVATION = 49.90. <br /> �� -- - -- - `� -.. •- - - 6 " CONNECTION :32.) REFER TO F XTURE IZE SCHEDULE SHEET P81 <br /> -. <br /> FOR CONNECTION SIZES TO THE VARIOUS FIXTURES. <br /> 3.) REFER TO PLUMBING LEGEND ON SHEET PS.1 FOR SYMBOLS. <br /> 4.) REFER TO ARCHITECTURAL DWG'8 FOR MOUNTING HEIGHTS <br /> ........ ........- ...... ____. --1. __ ..:..... .._____ I ...._..... ......_ OF ALL FIXTURES. <br /> 1 5.) ALL VENTS ARE TO BE LOCATED A MINIMUM OF 10'-0" AWAY <br /> FROM OUTSIDE AIR INTAKE. <br /> 6.) REFER TO SPECIFICATIONS SHEET P9.1 FOR PIPE MATERIAL <br /> . ,�y941QYy SPECIFICAITON. <br /> ELEVENTH STREET tiW ��V� A'Scyc 'Id RAIN WATER LEADERS INSTALLED IN CONDITIONED SPACES <br /> ti° Fr SHOULD BE WRAPPED WITH INSULATION TO PREVENT <br /> 0o CONDENSATION. L`:o <br /> M <br /> 't Exp. 099-30_30-10 * � •� � <br /> N'"TFOF aQ1°Q2 FIRE SPRINKLER NOTES <br /> ALEXANDER SCHEFLO L THE FIRE SPRINKLER CONTRACTOR SHALL PROVIDE <br /> and ASSOCIATES, Inc. <br /> A COMPLETE AND SEPARATE SUBMITTAL AS REQUIRED <br /> Mechanical Engineers 209 948-9761 FOR THE AUTOMATIC FIRE SPRINKLER SYSTEM. SAID <br /> 8 ( ) SYSTEM SHALL COMPLY WITH ALL OF THE PROVISIONS <br /> 2926 Pacific Ave. Stockton, Ca. 95204 OF THE CITY OF TRACY FIRE SPRINKLER SYSTEM •� <br /> -NORTH- DESIGN GUIDELINES AND SHALL BE REVIEWED AND <br /> PLUMBING �'�� ���� ALL TITUT S ANO WRITTEN MATERIAL APPEARING HEREIN APPROVED BY THE FIRE DEPARTMENT PRIOR TO Lao <br /> �i D D ^ COGINEER E THE ORIGINAL AND UNPUBLISHED WORK OF THE <br /> ENGINEER AND THE SAME MAY NOT BE USED, DUPLICATED. OR INSTALLATION WORK ISN BE PERFORMED OT A <br /> DISCLOSED WITHOUT THE WRITTEN CONSENT Of THE ENGINEER. CALIFORNIA STATE LICENSED C-16 (FIRE PROTECTION) <br /> SCALE: I"=30'-0" ,d Alexander Scheflo & Assoc., Inc CONTRACTOR <br /> o <br /> 0 <br /> I • R <br /> `O - FIRE RISER LEGEND <br /> WATER SERVICE AND SANITARY A <br /> SERVICE IF PLACED IN THE 1O. 4-WAY EARTHQUAKE BRACING (PER N.F.P.A. #13) L��L •� t-- <br /> SAME TRENCH SHALL HAVE M&H VALVE & FITTING CO. 2 <br /> N A LATERAL CLEARANCE OF O O / <br /> N 2. 4" GROOVED 90" ELL W 4" FLEX COUP. <br /> IRON FERRULE WITH CONCRETE PAD 30" MIN. 2 PIECE, 5-1/4 SHAFT, SCREW ^ •� ' <br /> BRASS COUNTERSUNK 18"SQUARE E6 3 "3O. 10ELECT. BELL <br /> o TYPE, CAT.NO. 461.5 OR p M <br /> CLEANOUT PLUG 1 CLEAR TOP OF EQUAL WITH WATER COVER +9'-T" <br /> U- 4 -- 4O. 4' FLOW SWITCH. <br /> - -- Y <br /> U PROJECTION BACKFILLED TRENCH METAL COVER PLAN 13 ® O _______ NOT USED - �n <br /> 3 PROVIDE SLEEVE 1/2" ------ U s <br /> 0 <br /> �� CLEAR AROUND PIPE FINISHED GRADE 1" CHAMFER <br /> a L °• o°• FINISH GRADE O 30' t4 6O. ------- NOT USED ------- <br /> NO.3 REINF.BARS WATER 4 <br /> N ---•5'_6" 7�. ------- NOT USED ------- <br /> TWO EACH WAY CAST IRON 2-WAY + 12" 18"x 18" CONO,COLLAR <br /> n COMBINATION FITTING -`- SANITARY SEWER 4" GROOVED "CENTRAL" SHOT-GUN-90 RISER <br /> 0 MIN g -- VA. W/ TRIM. <br /> s W/ NO-HUS BANDS 6"MIN 9"MIN <br /> SLOPE NOT MORE THAN 907 COMPACTED SOIL <br /> a OPEN TRENCH 1 IN 2, PIPE MUST NOT BE 4" GROOVED BUTTERFLY VALVE W/ TAMPER <br /> IIIA PLACED BELOW THIS LINE +3-10�i" 9 <br /> i � 1 10 4" FLEXIBLE GROOVED COUPLING <br /> a <br /> E 2 2" R2 17. 6"x11" REDUCING FLANGE <br /> d NOTE: CONCRETE AND SLEEVE <br /> FOR CASES RW LESS THAN +1'-6" _ 12 6" DUCTILE IRON UNDERGROUND SUPPLY <br /> i CONCRETE PAD TO BE FLUSH WITH FULL WIDTH NOT LESS NOT LESS 3'-0", OTHERWISE USE GATE VALVE 10 <br /> FINISH GRADE IN PAVED AREAS <br /> w STEPPED FOOTING <br /> Q THAN 18" 6"MIN THAN 16" RI 13 12 CAP. SPARE HEAD BOX W/ WRENCH ®I <br /> .1 NOTE: ,0,-y:,- II 14 HYDRAULIC INFORMATION PLACARD DATE 01/13/10 <br /> CONTRACTOR SHALL CONFER WITH GENERAL <br /> i CONTRACTOR WHERE CONDITIONS OCCUR - R1 4x2-4Yz GRV. x GRV. DRAWN BY <br /> w 6�� 12 R2 4x1-O GRV. x FLG. CHECKED BY S. PRUITT <br /> ti R3 44-2 GRV. x GRV. M.SCHEFLO <br /> i <br /> i JOB NO. 09084 <br /> 2-WAY CLEANOUTPPE STHENC H WATER VALVE (ZONE CONTROL)LD FIRE P1 . 1 <br /> u O GRADE DETAIL <br /> NOT TO SCALE DE� „ I� NOT TO SCALE D OX DE� „ IL NOT TO SCALE S SPRINKLER RISEN DETAIL NOT TO SCALE <br /> ( 4 <br /> �g OF X SHEETS <br />