D. Results of Testing/Servicing i • <br /> Software Version Installed: <br /> Com lete the following checklist: <br /> (X)Yes ❑ No* Is the audible alarm operational? <br /> (X)Yes ❑ No* Is the visual alarm operational? <br /> (X)Yes 4 No* Were all sensors visually inspected, functionally tested,and confirmed operational? <br /> (X)Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br /> not interfere with their proper operation? <br /> )Yes ( )No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g, modem) <br /> (x)N/A operational? <br /> ( )Yes (x)No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br /> ( )N/A monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate <br /> positive shut-down? (Check all Haat apply) ❑ Sump/Trench Sensors; 3 Dispenser Containment Sensors. <br /> Did you confirm Rositive shutdown due to leaks and sensor failure/disconnection? ❑Yes; d No. N/A <br /> O Yes (x)No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i,e, no <br /> N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> fill point(s)and operating property? If so,at what percent of tank capacity cbes the alarm trio cr7 % <br /> ( <br /> )Y"* (x)No Was any monitoring equipment replaced? If yes,identify specific sensors, probes,or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts in Section E, below. <br /> (x)Yes* ( )No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) ❑ <br /> Product; II Water. If yes,describe causes in Section E, below. <br /> (x)Y'es ❑ No* Was monitoring system set-Lip reviewed to ensure Cropur Settings? Attach set tire orts, if a licable <br /> x Yes ❑ No* is all monitoring equipment oerational per manufacturer's s ecifications? <br /> * In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E .Comments: Reprogrammed Sensor Names to Correspond to there physical location . <br /> A small amount of water was found in piping sump 92 approximately 3 to 4 oz. also found water in <br /> piping sump #6 approximately 14/2 to 2 Gals in the non-sensor side of sump removed water. A small <br /> amount of water was found in piping sump #S; S to 10 oz <br /> Mothering 9yetcm Certtacntion Pngc 3 nr4 12/t17 <br /> in-,rank Gaining/ SIR 11'quipment: ( x) Check this box if tank gauging is used only for inventory control. <br /> ( ) Check this box if no tank gauging or SIR equipment is installed. <br />